An Exploratory Study of Peripheral Vestibular System in Users of Personal Listening Devices.

IF 1.1 Q3 OTORHINOLARYNGOLOGY
Journal of Audiology and Otology Pub Date : 2025-01-01 Epub Date: 2025-01-20 DOI:10.7874/jao.2024.00164
Teja Deepak Dessai, Kaushlendra Kumar, Rashmi J Bhat
{"title":"An Exploratory Study of Peripheral Vestibular System in Users of Personal Listening Devices.","authors":"Teja Deepak Dessai, Kaushlendra Kumar, Rashmi J Bhat","doi":"10.7874/jao.2024.00164","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>The widespread use of mobile phones and personal listening devices (PLDs) poses potential health risks, particularly noise-induced hearing loss. Among younger generations, high-volume PLD use is associated with auditory and vestibular system changes. Clinical vestibular testing, including vestibular-evoked myogenic potentials (VEMP) and the video head impulse test (vHIT), may reveal peripheral vestibular impacts from prolonged PLD exposure at volumes over 60%. This study examines VEMP and vHIT results in individuals with normal hearing who have had extended high-volume PLD exposure. Subjects and.</p><p><strong>Methods: </strong>A cross-sectional comparative study was conducted on individuals aged 15-24 years. All the participants had normal pure tone thresholds with \"A\" type tympanogram, present acoustic reflexes, and history of PLD usage. Participants were divided into groups according to PLD exposure of <1 year (group A), 1.1-2 years (group B), 2.1-3 years (group C), and 3.1-4 years (group D). The output sound pressure level (dB SPL) near the tympanic membrane was measured. Furthermore, cervical VEMP, ocular VEMP, and vHIT were assessed.</p><p><strong>Results: </strong>The VEMP and vHIT findings were statistically analyzed and compared across groups. The peak-to-peak amplitudes of VEMP showed a statistically significant difference between groups A and D.</p><p><strong>Conclusions: </strong>Potential subclinical damage to the otolith organs can be associated with increased PLD exposure. No damage to the semi-circular canals was observed as the participants used lower dBA values by the PLDs.</p>","PeriodicalId":44886,"journal":{"name":"Journal of Audiology and Otology","volume":"29 1","pages":"22-30"},"PeriodicalIF":1.1000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11824530/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Audiology and Otology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7874/jao.2024.00164","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/20 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objectives: The widespread use of mobile phones and personal listening devices (PLDs) poses potential health risks, particularly noise-induced hearing loss. Among younger generations, high-volume PLD use is associated with auditory and vestibular system changes. Clinical vestibular testing, including vestibular-evoked myogenic potentials (VEMP) and the video head impulse test (vHIT), may reveal peripheral vestibular impacts from prolonged PLD exposure at volumes over 60%. This study examines VEMP and vHIT results in individuals with normal hearing who have had extended high-volume PLD exposure. Subjects and.

Methods: A cross-sectional comparative study was conducted on individuals aged 15-24 years. All the participants had normal pure tone thresholds with "A" type tympanogram, present acoustic reflexes, and history of PLD usage. Participants were divided into groups according to PLD exposure of <1 year (group A), 1.1-2 years (group B), 2.1-3 years (group C), and 3.1-4 years (group D). The output sound pressure level (dB SPL) near the tympanic membrane was measured. Furthermore, cervical VEMP, ocular VEMP, and vHIT were assessed.

Results: The VEMP and vHIT findings were statistically analyzed and compared across groups. The peak-to-peak amplitudes of VEMP showed a statistically significant difference between groups A and D.

Conclusions: Potential subclinical damage to the otolith organs can be associated with increased PLD exposure. No damage to the semi-circular canals was observed as the participants used lower dBA values by the PLDs.

个人助听器使用者外周前庭系统的探索性研究。
背景和目的:移动电话和个人听音设备的广泛使用构成了潜在的健康风险,特别是噪声性听力损失。在年轻一代中,大量使用PLD与听觉和前庭系统的变化有关。临床前庭测试,包括前庭诱发肌源电位(VEMP)和视频头部脉冲测试(vHIT),可以显示长时间暴露在超过60%的PLD对周围前庭的影响。本研究检查了听力正常但长期高音量PLD暴露的个体的VEMP和vHIT结果。主题和。方法:对15 ~ 24岁的个体进行横断面比较研究。所有的参与者都有正常的纯音阈值和“A”型鼓室图,目前的声学反射和PLD使用史。结果:对各组VEMP和vHIT结果进行统计分析和比较。VEMP的峰间振幅在a组和d组之间有统计学差异。结论:对耳石器官的潜在亚临床损伤可能与PLD暴露的增加有关。由于PLDs使用较低的dBA值,未观察到半圆形管道的损伤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Audiology and Otology
Journal of Audiology and Otology OTORHINOLARYNGOLOGY-
CiteScore
1.90
自引率
9.10%
发文量
20
期刊介绍: Journal of Audiology and Otology (JAO) (formerly known as Korean Journal of Audiology) aims to publish the most advanced findings for all aspects of the auditory and vestibular system and diseases of the ear using state-of-the-art techniques and analyses. The journal covers recent trends related to the topics of audiology, otology, and neurotology conducted by professionals, with the goal of providing better possible treatment to people of all ages, from infants to the elderly, who suffer from auditory and/or vestibular disorders and thus, improving their quality of life. This journal encourages the submission of review papers about current professional issues, research papers presenting a scientific base and clinical application, and case papers with unique reports or clinical trials. We also invite letters to the editor and papers related to the manufacture and distribution of medical devices. This journal provides integrated views from otologists, audiologists, and other healthcare practitioners, offering readers high quality scientific and clinical information. This peer-reviewed and open access journal has been the official journal of the Korean Audiological Society since 1997 and of both the Korean Audiological Society and the Korean Otological Society since 2017. It is published in English four times a year in January, April, July, and October.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信