{"title":"Internal adaptation assessment of implant infrastructures manufactured through five different techniques (heat-press, milling, lost wax, calcinable cylinder, and CAD/Waxx®): an <i>in vitro</i> pilot study.","authors":"Régis Sartori, Juliana Campos Hasse Fernandes, Gustavo Vicentis Oliveira Fernandes, Julio Cesar Joly","doi":"10.3389/fdmed.2024.1483177","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The aim of this study was to evaluate the fit performance of implant infrastructures manufactured by five different techniques: heat-press (IPS), milling (ZIR), lost wax (CER), calcinable cylinder (CAL), and CAD/Waxx® (CAD).</p><p><strong>Methods: </strong>The methodology was based on the Replica Technique, which can simulate and evaluate the fit of the infrastructure on the implant component. Thus, each infrastructure was internally filled with low-viscosity silicone addition and seated on the component until its final setting, obtaining the replica of the cementation space. After removing the coping containing the silicone film, light-density silicone was inserted addition in place of the components, and in its surroundings, condensation silicone was applied, establishing support for the assembly. The joint was sectioned mesiodistally, photographed, and analyzed in image processing software in order to measure the thickness of the interface infrastructure/implant at five different areas: marginal opening (M), gingival-axial angle (G-A), axial region (A), axial-occlusal angle (A-O) and occlusal surface (O).</p><p><strong>Results: </strong>The lowest and the highest average thickness between groups was, respectively, IPS: 187.5 μm and CAD: 221.6 μm, with statistically significant differences (<i>p</i> < 0.01) among all five groups; the lowest and the highest average of all groups in each point was, respectively, A: 99.86 μm and O: 279.78 μm. The IPS group exhibited the lowest value of the internal space of the infrastructure on the implant. The marginal region of all groups demonstrated a correlation with the findings in the literature, except the CAL group; otherwise, the occlusal region and the angles A-O and G-A exhibited values beyond that expected.</p><p><strong>Discussion: </strong>It was possible to conclude that the five infrastructure groups presented different adaptations, suggesting possible interference in the internal spaces due to the manufacturing infrastructure processes.</p>","PeriodicalId":73077,"journal":{"name":"Frontiers in dental medicine","volume":"5 ","pages":"1483177"},"PeriodicalIF":1.5000,"publicationDate":"2024-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11797799/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in dental medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fdmed.2024.1483177","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: The aim of this study was to evaluate the fit performance of implant infrastructures manufactured by five different techniques: heat-press (IPS), milling (ZIR), lost wax (CER), calcinable cylinder (CAL), and CAD/Waxx® (CAD).

Methods: The methodology was based on the Replica Technique, which can simulate and evaluate the fit of the infrastructure on the implant component. Thus, each infrastructure was internally filled with low-viscosity silicone addition and seated on the component until its final setting, obtaining the replica of the cementation space. After removing the coping containing the silicone film, light-density silicone was inserted addition in place of the components, and in its surroundings, condensation silicone was applied, establishing support for the assembly. The joint was sectioned mesiodistally, photographed, and analyzed in image processing software in order to measure the thickness of the interface infrastructure/implant at five different areas: marginal opening (M), gingival-axial angle (G-A), axial region (A), axial-occlusal angle (A-O) and occlusal surface (O).

Results: The lowest and the highest average thickness between groups was, respectively, IPS: 187.5 μm and CAD: 221.6 μm, with statistically significant differences (p < 0.01) among all five groups; the lowest and the highest average of all groups in each point was, respectively, A: 99.86 μm and O: 279.78 μm. The IPS group exhibited the lowest value of the internal space of the infrastructure on the implant. The marginal region of all groups demonstrated a correlation with the findings in the literature, except the CAL group; otherwise, the occlusal region and the angles A-O and G-A exhibited values beyond that expected.

Discussion: It was possible to conclude that the five infrastructure groups presented different adaptations, suggesting possible interference in the internal spaces due to the manufacturing infrastructure processes.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.10
自引率
0.00%
发文量
0
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信