Multiplex recombinase polymerase amplification (RPA) assay for carrier detection and prenatal diagnosis of α0-thalassemia (SEA and THAI deletions).

IF 1.3 4区 医学 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
Yanisa Sitthisophonkamjorn, Simaporn Prommetta, Attawut Chaibunruang, Hataichanok Srivorakun, Supan Fucharoen, Supawadee Yamsri
{"title":"Multiplex recombinase polymerase amplification (RPA) assay for carrier detection and prenatal diagnosis of α<sup>0</sup>-thalassemia (SEA and THAI deletions).","authors":"Yanisa Sitthisophonkamjorn, Simaporn Prommetta, Attawut Chaibunruang, Hataichanok Srivorakun, Supan Fucharoen, Supawadee Yamsri","doi":"10.1080/00365513.2025.2463071","DOIUrl":null,"url":null,"abstract":"<p><p>Hemoglobin Bart's hydrops fetalis is the most severe form of α-thalassemia, caused by homozygous α<sup>0</sup>-thalassemia, which is highly prevalent in Southeast Asian countries. Simple and rapid identification of α<sup>0</sup>-thalassemia carrier and prenatal diagnosis of Hemoglobin Bart's hydrops is essential in the region. We have developed a multiplex RPA assay for simple detection of α<sup>0</sup>-thalassemia (SEA and THAI deletions) and tested it in carrier detection (<i>n</i> = 125) and prenatal diagnosis of Hb Bart's hydrops fetalis syndrome (<i>n</i> = 30). The sensitivity, specificity, positive predictive value, and negative predictive value for detecting α<sup>0</sup>-thalassemia carriers were 100% for both SEA and THAI deletions. The assay correctly identified 42 carriers of α<sup>0</sup>-thalassemia (SEA deletion), 4 carriers of α<sup>0</sup>-thalassemia (THAI deletion), and 79 non-carriers. For prenatal diagnosis, the results of RPA revealed a 100% concordance (30/30) with the conventional gap-PCR analysis. The multiplex RPA assay is a rapid, reliable, and cost-effective method for diagnosing α<sup>0</sup>-thalassemia-related disorders in routine clinical settings. This assay has the potential to significantly contribute to the prevention and control of Hb Bart's hydrops fetalis in the region.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"1-7"},"PeriodicalIF":1.3000,"publicationDate":"2025-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Journal of Clinical & Laboratory Investigation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00365513.2025.2463071","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Hemoglobin Bart's hydrops fetalis is the most severe form of α-thalassemia, caused by homozygous α0-thalassemia, which is highly prevalent in Southeast Asian countries. Simple and rapid identification of α0-thalassemia carrier and prenatal diagnosis of Hemoglobin Bart's hydrops is essential in the region. We have developed a multiplex RPA assay for simple detection of α0-thalassemia (SEA and THAI deletions) and tested it in carrier detection (n = 125) and prenatal diagnosis of Hb Bart's hydrops fetalis syndrome (n = 30). The sensitivity, specificity, positive predictive value, and negative predictive value for detecting α0-thalassemia carriers were 100% for both SEA and THAI deletions. The assay correctly identified 42 carriers of α0-thalassemia (SEA deletion), 4 carriers of α0-thalassemia (THAI deletion), and 79 non-carriers. For prenatal diagnosis, the results of RPA revealed a 100% concordance (30/30) with the conventional gap-PCR analysis. The multiplex RPA assay is a rapid, reliable, and cost-effective method for diagnosing α0-thalassemia-related disorders in routine clinical settings. This assay has the potential to significantly contribute to the prevention and control of Hb Bart's hydrops fetalis in the region.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.50
自引率
4.80%
发文量
85
审稿时长
4-8 weeks
期刊介绍: The Scandinavian Journal of Clinical and Laboratory Investigation is an international scientific journal covering clinically oriented biochemical and physiological research. Since the launch of the journal in 1949, it has been a forum for international laboratory medicine, closely related to, and edited by, The Scandinavian Society for Clinical Chemistry. The journal contains peer-reviewed articles, editorials, invited reviews, and short technical notes, as well as several supplements each year. Supplements consist of monographs, and symposium and congress reports covering subjects within clinical chemistry and clinical physiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信