Predictive value of technetium-99m sodium pertechnetate thyroid scintigraphy in determining the permanence of congenital hypothyroidism.

IF 1.1 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Journal of Clinical Imaging Science Pub Date : 2025-01-15 eCollection Date: 2025-01-01 DOI:10.25259/JCIS_79_2024
Wai Ip Li, Tak Kwong Chan, Koon Kiu Ng, Boom Ting Kung
{"title":"Predictive value of technetium-99m sodium pertechnetate thyroid scintigraphy in determining the permanence of congenital hypothyroidism.","authors":"Wai Ip Li, Tak Kwong Chan, Koon Kiu Ng, Boom Ting Kung","doi":"10.25259/JCIS_79_2024","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>We aim to investigate the predictive value of [<sup>99m</sup>Tc] pertechnetate thyroid scintigraphy in determining the permanence of congenital hypothyroidism (CH).</p><p><strong>Material and methods: </strong>A retrospective analysis of [<sup>99m</sup>Tc] pertechnetate thyroid scans performed for evaluation of CH at the Nuclear Medicine Unit of a hospital in Hong Kong between January 1, 2008, and December 31, 2018, was conducted. Scintigraphic findings and parameters at diagnosis, including thyroid stimulating hormone (TSH), free thyroxine (fT4), gender, and gestational age, were reviewed. The need for lifelong thyroxine replacement therapy was reviewed.</p><p><strong>Results: </strong>The study included 85 subjects, with 74 (87.1%) presenting with eutopic thyroid and 11 (12.9%) showing thyroid dysgenesis. Patients with scintigraphic evidence of thyroid dysgenesis required permanent thyroid hormone replacement therapy. Among the patients with eutopic thyroid, a higher TSH level was associated with the need for lifelong thyroid hormone replacement therapy (cutoff TSH value 18.72 mIU/L, sensitivity 77.3% and specificity 53.8%). Gender, gestational age, and fT4 did not show significant differences between the transient and permanent CH groups in patients with eutopic thyroid.</p><p><strong>Conclusion: </strong>Scintigraphic findings of thyroid dysgenesis indicate a high prevalence of permanent CH. In patients with eutopic thyroid, higher TSH levels predict the requirement for lifelong thyroid hormone replacement therapy. These results provide insights into the prediction of CH and aid in individualized treatment decisions for patients with CH.</p>","PeriodicalId":15512,"journal":{"name":"Journal of Clinical Imaging Science","volume":"15 ","pages":"3"},"PeriodicalIF":1.1000,"publicationDate":"2025-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11801473/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Imaging Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25259/JCIS_79_2024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: We aim to investigate the predictive value of [99mTc] pertechnetate thyroid scintigraphy in determining the permanence of congenital hypothyroidism (CH).

Material and methods: A retrospective analysis of [99mTc] pertechnetate thyroid scans performed for evaluation of CH at the Nuclear Medicine Unit of a hospital in Hong Kong between January 1, 2008, and December 31, 2018, was conducted. Scintigraphic findings and parameters at diagnosis, including thyroid stimulating hormone (TSH), free thyroxine (fT4), gender, and gestational age, were reviewed. The need for lifelong thyroxine replacement therapy was reviewed.

Results: The study included 85 subjects, with 74 (87.1%) presenting with eutopic thyroid and 11 (12.9%) showing thyroid dysgenesis. Patients with scintigraphic evidence of thyroid dysgenesis required permanent thyroid hormone replacement therapy. Among the patients with eutopic thyroid, a higher TSH level was associated with the need for lifelong thyroid hormone replacement therapy (cutoff TSH value 18.72 mIU/L, sensitivity 77.3% and specificity 53.8%). Gender, gestational age, and fT4 did not show significant differences between the transient and permanent CH groups in patients with eutopic thyroid.

Conclusion: Scintigraphic findings of thyroid dysgenesis indicate a high prevalence of permanent CH. In patients with eutopic thyroid, higher TSH levels predict the requirement for lifelong thyroid hormone replacement therapy. These results provide insights into the prediction of CH and aid in individualized treatment decisions for patients with CH.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Clinical Imaging Science
Journal of Clinical Imaging Science RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.00
自引率
0.00%
发文量
65
期刊介绍: The Journal of Clinical Imaging Science (JCIS) is an open access peer-reviewed journal committed to publishing high-quality articles in the field of Imaging Science. The journal aims to present Imaging Science and relevant clinical information in an understandable and useful format. The journal is owned and published by the Scientific Scholar. Audience Our audience includes Radiologists, Researchers, Clinicians, medical professionals and students. Review process JCIS has a highly rigorous peer-review process that makes sure that manuscripts are scientifically accurate, relevant, novel and important. Authors disclose all conflicts, affiliations and financial associations such that the published content is not biased.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信