Randomized Trial of Biolimus DCB for In-Stent Restenosis

IF 11.7 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Robert A. Byrne MB BCh, PhD , Joo-Yong Hahn MD, PhD , Peter O’Kane MD , Manel Sabaté MD , Ralph Toelg MD , Samuel Copt PhD , Sean Fitzgerald MB BCh , Marie-Claude Morice MD , Jasper Trevelyan MD , Darren Mylotte MD , Antonio Fernandez Ortiz MD, PhD , Himanshu Rai PhD , Rory Durand MB BCh , Jochen Wöhrle MD , Franz Xever Kleber MD , Giuilo Stefanini MD , Fernando Alfonso MD, PhD
{"title":"Randomized Trial of Biolimus DCB for In-Stent Restenosis","authors":"Robert A. Byrne MB BCh, PhD ,&nbsp;Joo-Yong Hahn MD, PhD ,&nbsp;Peter O’Kane MD ,&nbsp;Manel Sabaté MD ,&nbsp;Ralph Toelg MD ,&nbsp;Samuel Copt PhD ,&nbsp;Sean Fitzgerald MB BCh ,&nbsp;Marie-Claude Morice MD ,&nbsp;Jasper Trevelyan MD ,&nbsp;Darren Mylotte MD ,&nbsp;Antonio Fernandez Ortiz MD, PhD ,&nbsp;Himanshu Rai PhD ,&nbsp;Rory Durand MB BCh ,&nbsp;Jochen Wöhrle MD ,&nbsp;Franz Xever Kleber MD ,&nbsp;Giuilo Stefanini MD ,&nbsp;Fernando Alfonso MD, PhD","doi":"10.1016/j.jcin.2024.11.026","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>In recent years, drug-coated balloon (DCB) angioplasty has become an established treatment option for the treatment of coronary in-stent restenosis (ISR).</div></div><div><h3>Objectives</h3><div>The aim of this study was to compare the angiographic and clinical performance of the Biolimus A9–coated balloon (BCB; Biosensors Europe) with that of the paclitaxel-coated balloon (PCB; SeQuent Please, Braun Melsungen).</div></div><div><h3>Methods</h3><div>REFORM (Prospective, Randomized, Non-Inferiority Trial to Determine the Safety and Efficacy of the Biolimus A9™ Drug Coated Balloon for the Treatment of In-Stent Restenosis: First-in-Man Trial) was a multicenter, assessor-blinded, noninferiority, 2:1 randomized controlled trial comparing the BCB and the PCB for the treatment of coronary ISR. The primary endpoint was in-segment percentage diameter stenosis at 6 months. Secondary endpoints included target lesion failure. The trial was registered prospectively at ClinicalTrials.gov (<span><span>NCT04079192</span><svg><path></path></svg></span>).</div></div><div><h3>Results</h3><div>A total of 202 patients were randomized at 20 centers in 6 countries, with 135 in the BCB group and 67 in the PCB group. The mean patient age was 68.5 ± 10 years. At 6 months, in-segment percentage diameter stenosis was 43.3% ± 22.9% in the BCB group compared with 31.4% ± 17.7% in the PCB group (95% CI for the difference: 4.9%-18.8%; prespecified noninferiority margin 12%, noninferiority <em>P</em> = 0.48). At 1 year, target lesion failure was observed in 23.7% of patients in the BCB group vs 17.1% in the PCB group (HR: 1.44; 95% CI: 0.72-2.88; <em>P</em> = 0.28).</div></div><div><h3>Conclusions</h3><div>In patients with ISR, the REFORM study failed to demonstrate noninferiority of the investigational biolimus DCB compared with the standard paclitaxel DCB.</div></div>","PeriodicalId":14688,"journal":{"name":"JACC. Cardiovascular interventions","volume":"18 5","pages":"Pages 654-662"},"PeriodicalIF":11.7000,"publicationDate":"2025-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JACC. Cardiovascular interventions","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1936879824017370","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

In recent years, drug-coated balloon (DCB) angioplasty has become an established treatment option for the treatment of coronary in-stent restenosis (ISR).

Objectives

The aim of this study was to compare the angiographic and clinical performance of the Biolimus A9–coated balloon (BCB; Biosensors Europe) with that of the paclitaxel-coated balloon (PCB; SeQuent Please, Braun Melsungen).

Methods

REFORM (Prospective, Randomized, Non-Inferiority Trial to Determine the Safety and Efficacy of the Biolimus A9™ Drug Coated Balloon for the Treatment of In-Stent Restenosis: First-in-Man Trial) was a multicenter, assessor-blinded, noninferiority, 2:1 randomized controlled trial comparing the BCB and the PCB for the treatment of coronary ISR. The primary endpoint was in-segment percentage diameter stenosis at 6 months. Secondary endpoints included target lesion failure. The trial was registered prospectively at ClinicalTrials.gov (NCT04079192).

Results

A total of 202 patients were randomized at 20 centers in 6 countries, with 135 in the BCB group and 67 in the PCB group. The mean patient age was 68.5 ± 10 years. At 6 months, in-segment percentage diameter stenosis was 43.3% ± 22.9% in the BCB group compared with 31.4% ± 17.7% in the PCB group (95% CI for the difference: 4.9%-18.8%; prespecified noninferiority margin 12%, noninferiority P = 0.48). At 1 year, target lesion failure was observed in 23.7% of patients in the BCB group vs 17.1% in the PCB group (HR: 1.44; 95% CI: 0.72-2.88; P = 0.28).

Conclusions

In patients with ISR, the REFORM study failed to demonstrate noninferiority of the investigational biolimus DCB compared with the standard paclitaxel DCB.
求助全文
约1分钟内获得全文 求助全文
来源期刊
JACC. Cardiovascular interventions
JACC. Cardiovascular interventions CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
11.60
自引率
8.80%
发文量
756
审稿时长
4-8 weeks
期刊介绍: JACC: Cardiovascular Interventions is a specialist journal launched by the Journal of the American College of Cardiology (JACC). It covers the entire field of interventional cardiovascular medicine, including cardiac, peripheral, and cerebrovascular interventions. The journal publishes studies that will impact the practice of interventional cardiovascular medicine, including clinical trials, experimental studies, and in-depth discussions by respected experts. To enhance visual understanding, the journal is published both in print and electronically, utilizing the latest technologies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信