{"title":"Improvement of Helium Liquefaction Performance Based on the Temperature-Distributed Regenerative Refrigeration Method Using 3He Fluid","authors":"Qiang Cao,&nbsp;Lichun Ge,&nbsp;Miaomiao Wang,&nbsp;Yuji Chen,&nbsp;Pengcheng Wang,&nbsp;Zhiping Wang,&nbsp;Peng Li,&nbsp;Qinyu Zhao,&nbsp;Bo Wang,&nbsp;Zhihua Gan","doi":"10.1007/s10909-024-03262-3","DOIUrl":null,"url":null,"abstract":"<div><p>Liquid helium has important applications in infrared wavelength detection, superconducting quantum interference, and so on. Regenerative refrigerators are generally applied for small-scale applications. However, the liquefaction efficiency of helium is not high. The main reason is the contradiction between the large sensible heat load and the limited refrigeration efficiency at 4.2 K. A novel method of temperature-distributed regenerative refrigeration, which generates the refrigeration power over a wide temperature range based on real gas effects, is theoretically studied using the <sup>3</sup>He working fluid for the first time. The liquefaction rate and efficiency of helium is improved because of a smaller entropy generation with this temperature-distributed method. The temperature-distributed refrigeration power of the <sup>3</sup>He working fluid is larger than that of <sup>4</sup>He when the absolute pressure is smaller, because the critical pressure of <sup>3</sup>He is lower; while such a refrigeration power of <sup>3</sup>He distributes at a lower temperature range that of <sup>4</sup>He at the same reduced pressure because the critical temperature of <sup>3</sup>He is lower. The liquefaction rate reaches 50.5 L/d when the cold-end refrigeration power is 1.5 W. This rate is 2–3 times that of liquefying with only the cold end with <sup>4</sup>He or <sup>3</sup>He. Furthermore, the liquefaction efficiency (FOM) increases with the rise in pressure. The theoretical FOM is 47.7% at a reduced pressure of 61.7 (14.1 MPa), which is a 7% improvement over the case with <sup>4</sup>He (44.7%). These results demonstrate advantages of using the temperature-distributed method with <sup>3</sup>He, thus opening up a new avenue for further researches in helium liquefaction systems.</p></div>","PeriodicalId":641,"journal":{"name":"Journal of Low Temperature Physics","volume":"218 3-4","pages":"305 - 323"},"PeriodicalIF":1.1000,"publicationDate":"2025-01-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Low Temperature Physics","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1007/s10909-024-03262-3","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
引用次数: 0

Abstract

Liquid helium has important applications in infrared wavelength detection, superconducting quantum interference, and so on. Regenerative refrigerators are generally applied for small-scale applications. However, the liquefaction efficiency of helium is not high. The main reason is the contradiction between the large sensible heat load and the limited refrigeration efficiency at 4.2 K. A novel method of temperature-distributed regenerative refrigeration, which generates the refrigeration power over a wide temperature range based on real gas effects, is theoretically studied using the 3He working fluid for the first time. The liquefaction rate and efficiency of helium is improved because of a smaller entropy generation with this temperature-distributed method. The temperature-distributed refrigeration power of the 3He working fluid is larger than that of 4He when the absolute pressure is smaller, because the critical pressure of 3He is lower; while such a refrigeration power of 3He distributes at a lower temperature range that of 4He at the same reduced pressure because the critical temperature of 3He is lower. The liquefaction rate reaches 50.5 L/d when the cold-end refrigeration power is 1.5 W. This rate is 2–3 times that of liquefying with only the cold end with 4He or 3He. Furthermore, the liquefaction efficiency (FOM) increases with the rise in pressure. The theoretical FOM is 47.7% at a reduced pressure of 61.7 (14.1 MPa), which is a 7% improvement over the case with 4He (44.7%). These results demonstrate advantages of using the temperature-distributed method with 3He, thus opening up a new avenue for further researches in helium liquefaction systems.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Low Temperature Physics
Journal of Low Temperature Physics 物理-物理:凝聚态物理
CiteScore
3.30
自引率
25.00%
发文量
245
审稿时长
1 months
期刊介绍: The Journal of Low Temperature Physics publishes original papers and review articles on all areas of low temperature physics and cryogenics, including theoretical and experimental contributions. Subject areas include: Quantum solids, liquids and gases; Superfluidity; Superconductivity; Condensed matter physics; Experimental techniques; The Journal encourages the submission of Rapid Communications and Special Issues.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信