{"title":"Performance of Hollow-Core Photonic Crystal Fiber-Based Trace C₂H₂ Detection System","authors":"Xianzong Chao;Fuping Zeng;Hongtu Cheng;Xinghai Jiang;Zujian Huang;Qiang Yao;Ju Tang","doi":"10.1109/TIM.2025.3534217","DOIUrl":null,"url":null,"abstract":"In this article, we propose an optical sensor system utilizing the capabilities of hollow-core photonic crystal fiber (HC-PCF) to transmit excitation light and hold sample gas. The direct absorption response is examined for different modulation waveforms, pressures, frequencies, and concentrations. The experimental results show that the response signal has an obvious overshoot and spike. The overshoot and spike are more obvious under the sine modulation than the rectangular modulation. In the 1–500-Hz range, the system demonstrated optimum response characteristics at 5 Hz, corresponding to the maximum attenuation percentage. Furthermore, a positive correlation was observed between the attenuation percentage of light intensity (<inline-formula> <tex-math>${A} _{\\text {t}}$ </tex-math></inline-formula>) and optical power (<inline-formula> <tex-math>${A} _{\\text {p}}$ </tex-math></inline-formula>) with the pressure in the gas chamber within the range of 0.1–0.3 MPa. When the gas chamber is filled with 10000-ppm C2H2/N2 to 0.3 MPa, At and Ap are 47.98% and 22.73%, respectively. A good linear relationship exists between the attenuation value of photodetector (PD) output and target gas concentration with a correlation coefficient above 0.99 after 140 s. The theoretical minimum detection limit of C2H2 without the erbium-doped fiber amplifier (EDFA) is 49.28 ppm and the relative synthetic standard uncertainty is 3.35%. This article provides an idea for applying the HC-PCF-based gas sensing system.","PeriodicalId":13341,"journal":{"name":"IEEE Transactions on Instrumentation and Measurement","volume":"74 ","pages":"1-10"},"PeriodicalIF":5.6000,"publicationDate":"2025-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Instrumentation and Measurement","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10876412/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

In this article, we propose an optical sensor system utilizing the capabilities of hollow-core photonic crystal fiber (HC-PCF) to transmit excitation light and hold sample gas. The direct absorption response is examined for different modulation waveforms, pressures, frequencies, and concentrations. The experimental results show that the response signal has an obvious overshoot and spike. The overshoot and spike are more obvious under the sine modulation than the rectangular modulation. In the 1–500-Hz range, the system demonstrated optimum response characteristics at 5 Hz, corresponding to the maximum attenuation percentage. Furthermore, a positive correlation was observed between the attenuation percentage of light intensity ( ${A} _{\text {t}}$ ) and optical power ( ${A} _{\text {p}}$ ) with the pressure in the gas chamber within the range of 0.1–0.3 MPa. When the gas chamber is filled with 10000-ppm C2H2/N2 to 0.3 MPa, At and Ap are 47.98% and 22.73%, respectively. A good linear relationship exists between the attenuation value of photodetector (PD) output and target gas concentration with a correlation coefficient above 0.99 after 140 s. The theoretical minimum detection limit of C2H2 without the erbium-doped fiber amplifier (EDFA) is 49.28 ppm and the relative synthetic standard uncertainty is 3.35%. This article provides an idea for applying the HC-PCF-based gas sensing system.
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Instrumentation and Measurement
IEEE Transactions on Instrumentation and Measurement 工程技术-工程:电子与电气
CiteScore
9.00
自引率
23.20%
发文量
1294
审稿时长
3.9 months
期刊介绍: Papers are sought that address innovative solutions to the development and use of electrical and electronic instruments and equipment to measure, monitor and/or record physical phenomena for the purpose of advancing measurement science, methods, functionality and applications. The scope of these papers may encompass: (1) theory, methodology, and practice of measurement; (2) design, development and evaluation of instrumentation and measurement systems and components used in generating, acquiring, conditioning and processing signals; (3) analysis, representation, display, and preservation of the information obtained from a set of measurements; and (4) scientific and technical support to establishment and maintenance of technical standards in the field of Instrumentation and Measurement.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信