Influence of Sample Surface Oil on the Accuracy of Space Charge Measurement in Oil-Paper

IF 2.9 3区 工程技术 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC
Yuntong Ma;Zepeng Lv;Xinyue Zhang;Yining Zhang;Kai Wu;Yonghong Cheng
{"title":"Influence of Sample Surface Oil on the Accuracy of Space Charge Measurement in Oil-Paper","authors":"Yuntong Ma;Zepeng Lv;Xinyue Zhang;Yining Zhang;Kai Wu;Yonghong Cheng","doi":"10.1109/TDEI.2024.3478131","DOIUrl":null,"url":null,"abstract":"Space charge in oil-paper under dc electric field is a significant factor for the development of converter transformer. The space charge in oil-paper is usually measured by a pulsed electroacoustic (PEA) method. But, its accuracy is not good that the surface charge amount at electrode cannot match the bulk charge-induced charge. In this article, space charge distributions in oil-paper samples with and without surface oil are measured and analyzed. The amount of bulk charge in the sample without surface oil is larger than that in the sample with surface oil. In the sample with surface oil, the amount of surface charge at lower electrode has a distinct error that it is much higher than the bulk charge-induced charge. The space charge-induced charge at lower electrode is calculated and compared with the measured surface charge. It is found that surface oil on the sample can greatly influence the amount of surface charge at electrodes. In the sample without surface oil, the measured surface charge at lower electrode has similar amount with the bulk charge-induced charge. In the sample with surface oil, the quantity of the measured surface charge is much higher than that of the induced charge. Besides, the bulk charge amount is less in the sample with surface oil. It indicates that the space charge injected from upper electrode to surface oil interferes the development of surface charge at electrodes during voltage application. During voltage removal, the charges in the surface oil induce more charges at lower electrode. Therefore, it is suggested to remove surface oil on oil-paper samples for an accurate space charge measurement.","PeriodicalId":13247,"journal":{"name":"IEEE Transactions on Dielectrics and Electrical Insulation","volume":"32 1","pages":"624-626"},"PeriodicalIF":2.9000,"publicationDate":"2024-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Dielectrics and Electrical Insulation","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10713435/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Space charge in oil-paper under dc electric field is a significant factor for the development of converter transformer. The space charge in oil-paper is usually measured by a pulsed electroacoustic (PEA) method. But, its accuracy is not good that the surface charge amount at electrode cannot match the bulk charge-induced charge. In this article, space charge distributions in oil-paper samples with and without surface oil are measured and analyzed. The amount of bulk charge in the sample without surface oil is larger than that in the sample with surface oil. In the sample with surface oil, the amount of surface charge at lower electrode has a distinct error that it is much higher than the bulk charge-induced charge. The space charge-induced charge at lower electrode is calculated and compared with the measured surface charge. It is found that surface oil on the sample can greatly influence the amount of surface charge at electrodes. In the sample without surface oil, the measured surface charge at lower electrode has similar amount with the bulk charge-induced charge. In the sample with surface oil, the quantity of the measured surface charge is much higher than that of the induced charge. Besides, the bulk charge amount is less in the sample with surface oil. It indicates that the space charge injected from upper electrode to surface oil interferes the development of surface charge at electrodes during voltage application. During voltage removal, the charges in the surface oil induce more charges at lower electrode. Therefore, it is suggested to remove surface oil on oil-paper samples for an accurate space charge measurement.
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Dielectrics and Electrical Insulation
IEEE Transactions on Dielectrics and Electrical Insulation 工程技术-工程:电子与电气
CiteScore
6.00
自引率
22.60%
发文量
309
审稿时长
5.2 months
期刊介绍: Topics that are concerned with dielectric phenomena and measurements, with development and characterization of gaseous, vacuum, liquid and solid electrical insulating materials and systems; and with utilization of these materials in circuits and systems under condition of use.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信