IF 7.1 1区 工程技术 Q1 CONSTRUCTION & BUILDING TECHNOLOGY
Jinjun Ye , Zhengtao Ai , Lup Wai Chew
{"title":"Indoor pollution of funeral homes and potential health risk of workers: A case study in central China","authors":"Jinjun Ye ,&nbsp;Zhengtao Ai ,&nbsp;Lup Wai Chew","doi":"10.1016/j.buildenv.2025.112677","DOIUrl":null,"url":null,"abstract":"<div><div>Funeral services play a vital role in the social fabric, yet the pollutants and occupational exposures in the indoor environment of funeral homes remain unknown. To address this gap, this study conducted a comprehensive screening of pollutants, including organic and inorganic chemicals, as well as bacteria, in the dressing-morgue and cremation room of a funeral home in Changsha. It was found that 151 VOCs and 29 SVOCs were detected in the dressing-morgue, while 129 VOCs and 38 SVOCs in the cremation room. Notably, these organic chemicals demonstrated saturation levels (double bond equivalent (DBE) = 3.3-3.4) that fell between outdoor air chemicals (DBE = 7.3) and those released from corpses (DBE = 1.5). In the dressing-morgue and cremation room, 4 and 3 chemicals posed a non-cancer risk (HQ) above the safety threshold (1.0), respectively; and 8 and 6 chemicals posed an incremental lifetime cancer risk (ILCR) above the safety threshold (1.0 × 10<sup>-6</sup>), respectively. In the dressing-morgue, the highest HQ and ILCR were 145.0 (Acrolein) and 1.2 × 10<sup>-4</sup> (Cobalt), respectively; while in the cremation room, there were 65.0 (Acrolein) and 2.0 × 10<sup>-5</sup> (1,2-Dibromoethane), respectively. In terms of bacteria, Alpha and Beta diversity analysis indicated that airborne bacterial community in both workspaces were highly similar, while surface-adhered bacteria displayed higher diversity. In both workspaces, Bacteroides was the predominant airborne pathogenic genus. These findings present the first disclosure of pollution conditions in funeral homes, aiming to raise societal awareness about the occupational exposure and to motivate the development of evidence-based solutions.</div></div>","PeriodicalId":9273,"journal":{"name":"Building and Environment","volume":"272 ","pages":"Article 112677"},"PeriodicalIF":7.1000,"publicationDate":"2025-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building and Environment","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0360132325001593","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Funeral services play a vital role in the social fabric, yet the pollutants and occupational exposures in the indoor environment of funeral homes remain unknown. To address this gap, this study conducted a comprehensive screening of pollutants, including organic and inorganic chemicals, as well as bacteria, in the dressing-morgue and cremation room of a funeral home in Changsha. It was found that 151 VOCs and 29 SVOCs were detected in the dressing-morgue, while 129 VOCs and 38 SVOCs in the cremation room. Notably, these organic chemicals demonstrated saturation levels (double bond equivalent (DBE) = 3.3-3.4) that fell between outdoor air chemicals (DBE = 7.3) and those released from corpses (DBE = 1.5). In the dressing-morgue and cremation room, 4 and 3 chemicals posed a non-cancer risk (HQ) above the safety threshold (1.0), respectively; and 8 and 6 chemicals posed an incremental lifetime cancer risk (ILCR) above the safety threshold (1.0 × 10-6), respectively. In the dressing-morgue, the highest HQ and ILCR were 145.0 (Acrolein) and 1.2 × 10-4 (Cobalt), respectively; while in the cremation room, there were 65.0 (Acrolein) and 2.0 × 10-5 (1,2-Dibromoethane), respectively. In terms of bacteria, Alpha and Beta diversity analysis indicated that airborne bacterial community in both workspaces were highly similar, while surface-adhered bacteria displayed higher diversity. In both workspaces, Bacteroides was the predominant airborne pathogenic genus. These findings present the first disclosure of pollution conditions in funeral homes, aiming to raise societal awareness about the occupational exposure and to motivate the development of evidence-based solutions.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Building and Environment
Building and Environment 工程技术-工程:环境
CiteScore
12.50
自引率
23.00%
发文量
1130
审稿时长
27 days
期刊介绍: Building and Environment, an international journal, is dedicated to publishing original research papers, comprehensive review articles, editorials, and short communications in the fields of building science, urban physics, and human interaction with the indoor and outdoor built environment. The journal emphasizes innovative technologies and knowledge verified through measurement and analysis. It covers environmental performance across various spatial scales, from cities and communities to buildings and systems, fostering collaborative, multi-disciplinary research with broader significance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信