Experimental investigation of an Auto-Switching SH TEG/PCM unit for consistent All-Day electric power generation

IF 9.9 1区 工程技术 Q1 ENERGY & FUELS
Jinglong Wang, Lin Lu, Kai Jiao, Miao Han
{"title":"Experimental investigation of an Auto-Switching SH TEG/PCM unit for consistent All-Day electric power generation","authors":"Jinglong Wang,&nbsp;Lin Lu,&nbsp;Kai Jiao,&nbsp;Miao Han","doi":"10.1016/j.enconman.2025.119556","DOIUrl":null,"url":null,"abstract":"<div><div>In the pursuit of sustainable energy solutions, combining a thermoelectric generator (TEG) with a phase change material (PCM) powered by solar energy shows promise for consistent electricity generation (EG). Despite extensive research on solar-heating TEG/PCM systems, there is a lack of studies directly utilizing sunlight, with heaters commonly used as substitutes, thus overlooking the influence of solar radiation spectrum and intensity. This study examines auto-switching SH TEG/PCM unit performance under simulated solar irradiation, presenting an experimental setup and theoretical model for system analysis. Results show that the total EG over 24 h relies on the EG during the lighted operation phase (LOP). Once the PCM in the aluminum box (AB) fully melts, a secondary temperature rise near the bottom of the top cover occurs during the transition to static phase (TSP). Unit 80-AB achieves the highest total EG under a total solar irradiance of 4 kW⋅h/m<sup>2</sup>, with values of 3.72 and 0.15 W⋅h/m<sup>2</sup> for the LOP and TSP, and when exposed to 8 SSs for 5 h, it peaks at 4.4 and 0.19 W⋅h/m<sup>2</sup> for the LOP and TSP, respectively. Additionally, the EG for unit 80-AB is maximal after almost 10-hour exposure, with the insulated unit featuring a film achieving a total EG of 8.78 W⋅h/m<sup>2</sup>, exceeding the bare unit and insulated unit by 1.06 and 1.54 W⋅h/m<sup>2</sup>, respectively. During the LOP, the experimental unit 80-AB can achieve a maximum increase in EG of 7.71 W⋅h/m<sup>2</sup> in the bare mode compared to the control unit. The open-circuit voltage of unit 80-AB reaches approximately 110 mV, with the maximum output power amounting to 0.34 W/m<sup>2</sup> when the load resistance is 5 Ω. The proposed units present a practical solution for continuous EG throughout the day, guaranteeing a reliable energy provision and heralding an environmentally sustainable energy paradigm.</div></div>","PeriodicalId":11664,"journal":{"name":"Energy Conversion and Management","volume":"327 ","pages":"Article 119556"},"PeriodicalIF":9.9000,"publicationDate":"2025-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Conversion and Management","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0196890425000792","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

In the pursuit of sustainable energy solutions, combining a thermoelectric generator (TEG) with a phase change material (PCM) powered by solar energy shows promise for consistent electricity generation (EG). Despite extensive research on solar-heating TEG/PCM systems, there is a lack of studies directly utilizing sunlight, with heaters commonly used as substitutes, thus overlooking the influence of solar radiation spectrum and intensity. This study examines auto-switching SH TEG/PCM unit performance under simulated solar irradiation, presenting an experimental setup and theoretical model for system analysis. Results show that the total EG over 24 h relies on the EG during the lighted operation phase (LOP). Once the PCM in the aluminum box (AB) fully melts, a secondary temperature rise near the bottom of the top cover occurs during the transition to static phase (TSP). Unit 80-AB achieves the highest total EG under a total solar irradiance of 4 kW⋅h/m2, with values of 3.72 and 0.15 W⋅h/m2 for the LOP and TSP, and when exposed to 8 SSs for 5 h, it peaks at 4.4 and 0.19 W⋅h/m2 for the LOP and TSP, respectively. Additionally, the EG for unit 80-AB is maximal after almost 10-hour exposure, with the insulated unit featuring a film achieving a total EG of 8.78 W⋅h/m2, exceeding the bare unit and insulated unit by 1.06 and 1.54 W⋅h/m2, respectively. During the LOP, the experimental unit 80-AB can achieve a maximum increase in EG of 7.71 W⋅h/m2 in the bare mode compared to the control unit. The open-circuit voltage of unit 80-AB reaches approximately 110 mV, with the maximum output power amounting to 0.34 W/m2 when the load resistance is 5 Ω. The proposed units present a practical solution for continuous EG throughout the day, guaranteeing a reliable energy provision and heralding an environmentally sustainable energy paradigm.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Energy Conversion and Management
Energy Conversion and Management 工程技术-力学
CiteScore
19.00
自引率
11.50%
发文量
1304
审稿时长
17 days
期刊介绍: The journal Energy Conversion and Management provides a forum for publishing original contributions and comprehensive technical review articles of interdisciplinary and original research on all important energy topics. The topics considered include energy generation, utilization, conversion, storage, transmission, conservation, management and sustainability. These topics typically involve various types of energy such as mechanical, thermal, nuclear, chemical, electromagnetic, magnetic and electric. These energy types cover all known energy resources, including renewable resources (e.g., solar, bio, hydro, wind, geothermal and ocean energy), fossil fuels and nuclear resources.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信