Evaluation of optimized Real time-PCR HRM assay and SPR-based biosensor for noninvasive isolation of H. pylori and Clarithromycin resistance 23S-SNP subtype

IF 2.1 4区 医学 Q3 INFECTIOUS DISEASES
Atena Abedi Maghami , Ashraf Mohabati Mobarez , Abbas Yadegar , Maryam Nikkhah , Amir Sadeghi , Marziyeh Mousazadeh
{"title":"Evaluation of optimized Real time-PCR HRM assay and SPR-based biosensor for noninvasive isolation of H. pylori and Clarithromycin resistance 23S-SNP subtype","authors":"Atena Abedi Maghami ,&nbsp;Ashraf Mohabati Mobarez ,&nbsp;Abbas Yadegar ,&nbsp;Maryam Nikkhah ,&nbsp;Amir Sadeghi ,&nbsp;Marziyeh Mousazadeh","doi":"10.1016/j.diagmicrobio.2025.116722","DOIUrl":null,"url":null,"abstract":"<div><div>High Resolution Melting analysis is a highly sensitive molecular method, and the plasmonic-based sensor is a convenient test, be clinically elicited, in simultaneous <em>H. pylori</em> control and the prevention of Clarithromycin resistant strains related to SNPs. Comparing gold standard tests, we evaluated HRMA and the SPR-based biosensor in regard to noninvasive forms of <em>H. pylori</em> management, and explored resistance through a possible mechanism by 23S-SNPs.We optimized Realtime-PCR HRM analysis, and SPR-based biosensor. Referring to CTs ± 38, isolation sensitivity was evaluated at 74 %. Compared to the reference-test, results agreements were assessed with a kappa of 43 %, <em>p</em> = 0.001. Within melting plots (differentiation plot), the strains were detectable at Tms ranging from 81.5 to 82.3 (°C). Contributing to phenotypically determined resistant strains for 44 %, there was a wide distribution among resistant variants assessed through Tms of 82, 81.5, 82, 82.3, and 81.7 (°C). A2143C was the only mutation isolated at a specific Tm of 82.3°C; kappa = 8 %, <em>p</em> = 0.3. For sensing analysis, including 100 % specificity, this sensor type was associated with lower sensitivity of 49 %, kappa=19 %, <em>p</em> = 0. 01. For SNP, specificity, kappa value, and p-value of isolation were 100 %, 100 %, and 0.001. Lod was 0.003 ng/mL and 0.03 µg/mL for HRM assay and sensing analysis. In our evaluations, applicable priority of HRM analysis was the higher estimation of sensitivity; its differentiation plot was completely covered the results of strain variability regarding specific SNPs detection. Consistent with the biosensor for isolation of SNP, the development of biosensors is the necessity for noninvasive <em>H. pylori</em> detection.</div></div>","PeriodicalId":11329,"journal":{"name":"Diagnostic microbiology and infectious disease","volume":"111 4","pages":"Article 116722"},"PeriodicalIF":2.1000,"publicationDate":"2025-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic microbiology and infectious disease","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0732889325000458","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0

Abstract

High Resolution Melting analysis is a highly sensitive molecular method, and the plasmonic-based sensor is a convenient test, be clinically elicited, in simultaneous H. pylori control and the prevention of Clarithromycin resistant strains related to SNPs. Comparing gold standard tests, we evaluated HRMA and the SPR-based biosensor in regard to noninvasive forms of H. pylori management, and explored resistance through a possible mechanism by 23S-SNPs.We optimized Realtime-PCR HRM analysis, and SPR-based biosensor. Referring to CTs ± 38, isolation sensitivity was evaluated at 74 %. Compared to the reference-test, results agreements were assessed with a kappa of 43 %, p = 0.001. Within melting plots (differentiation plot), the strains were detectable at Tms ranging from 81.5 to 82.3 (°C). Contributing to phenotypically determined resistant strains for 44 %, there was a wide distribution among resistant variants assessed through Tms of 82, 81.5, 82, 82.3, and 81.7 (°C). A2143C was the only mutation isolated at a specific Tm of 82.3°C; kappa = 8 %, p = 0.3. For sensing analysis, including 100 % specificity, this sensor type was associated with lower sensitivity of 49 %, kappa=19 %, p = 0. 01. For SNP, specificity, kappa value, and p-value of isolation were 100 %, 100 %, and 0.001. Lod was 0.003 ng/mL and 0.03 µg/mL for HRM assay and sensing analysis. In our evaluations, applicable priority of HRM analysis was the higher estimation of sensitivity; its differentiation plot was completely covered the results of strain variability regarding specific SNPs detection. Consistent with the biosensor for isolation of SNP, the development of biosensors is the necessity for noninvasive H. pylori detection.
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.30
自引率
3.40%
发文量
149
审稿时长
56 days
期刊介绍: Diagnostic Microbiology and Infectious Disease keeps you informed of the latest developments in clinical microbiology and the diagnosis and treatment of infectious diseases. Packed with rigorously peer-reviewed articles and studies in bacteriology, immunology, immunoserology, infectious diseases, mycology, parasitology, and virology, the journal examines new procedures, unusual cases, controversial issues, and important new literature. Diagnostic Microbiology and Infectious Disease distinguished independent editorial board, consisting of experts from many medical specialties, ensures you extensive and authoritative coverage.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信