Device Failures and Adverse Events Associated With Rhinolaryngoscopes: Analysis of the Manufacturer and User Facility Device Experience (MAUDE) Database.

IF 2.6 Q2 HEALTH CARE SCIENCES & SERVICES
JMIR Human Factors Pub Date : 2025-02-05 DOI:10.2196/67036
Shao-Hsuan Chang, Daishi Chen, Chi-Sheng Chen, Dong Zhou, Lung-Kun Yeh
{"title":"Device Failures and Adverse Events Associated With Rhinolaryngoscopes: Analysis of the Manufacturer and User Facility Device Experience (MAUDE) Database.","authors":"Shao-Hsuan Chang, Daishi Chen, Chi-Sheng Chen, Dong Zhou, Lung-Kun Yeh","doi":"10.2196/67036","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Rhinolaryngoscopes are one of the most widely used tools by otolaryngologists and speech-language pathologists in current clinical practice. However, there is limited data on adverse events associated with or caused by the use of rhinolaryngoscopes.</p><p><strong>Objective: </strong>In this study, we used the Manufacturer and User Facility Device Experience (MAUDE) database with the aim of providing insights that may assist otolaryngologists in better understanding the limitations of these devices and selecting appropriate procedures for their specific clinical setting.</p><p><strong>Methods: </strong>We characterized complications associated with the postmarket use of rhinolaryngoscope devices from the US Food and Drug Administration MAUDE database from 2016 through 2023.</p><p><strong>Results: </strong>A total of 2591 reports were identified, including 2534 device malfunctions, 56 injuries, and 1 death, from 2016 through 2023. The most common device problem with rhinolaryngoscopes was breakage (n=1058 reports, 40.8%), followed by fluid leaks (n=632 reports, 24.4%). The third most common problem was poor image quality (n=467 reports, 18%). Other device issues included contamination or device reprocessing problems (n=127 reports, 4.9%), material deformation or wear (n=125 reports, 4.8%), and device detachment (n=73 reports, 2.8%). Of the 63 reported adverse events, the most common patient-related adverse event was hemorrhage or bleeding, accounting for 18 reports, with the root causes including material deformation or wear, breakage, wrinkled rubber, or improper operation.</p><p><strong>Conclusions: </strong>Our study offers valuable insights for endoscopists and manufacturers to recognize potential issues and adverse events associated with the use of rhinolaryngoscopes. It emphasizes the need for improving device reliability, training, and procedural protocols to enhance patient safety during diagnostic procedures.</p>","PeriodicalId":36351,"journal":{"name":"JMIR Human Factors","volume":"12 ","pages":"e67036"},"PeriodicalIF":2.6000,"publicationDate":"2025-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JMIR Human Factors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2196/67036","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Rhinolaryngoscopes are one of the most widely used tools by otolaryngologists and speech-language pathologists in current clinical practice. However, there is limited data on adverse events associated with or caused by the use of rhinolaryngoscopes.

Objective: In this study, we used the Manufacturer and User Facility Device Experience (MAUDE) database with the aim of providing insights that may assist otolaryngologists in better understanding the limitations of these devices and selecting appropriate procedures for their specific clinical setting.

Methods: We characterized complications associated with the postmarket use of rhinolaryngoscope devices from the US Food and Drug Administration MAUDE database from 2016 through 2023.

Results: A total of 2591 reports were identified, including 2534 device malfunctions, 56 injuries, and 1 death, from 2016 through 2023. The most common device problem with rhinolaryngoscopes was breakage (n=1058 reports, 40.8%), followed by fluid leaks (n=632 reports, 24.4%). The third most common problem was poor image quality (n=467 reports, 18%). Other device issues included contamination or device reprocessing problems (n=127 reports, 4.9%), material deformation or wear (n=125 reports, 4.8%), and device detachment (n=73 reports, 2.8%). Of the 63 reported adverse events, the most common patient-related adverse event was hemorrhage or bleeding, accounting for 18 reports, with the root causes including material deformation or wear, breakage, wrinkled rubber, or improper operation.

Conclusions: Our study offers valuable insights for endoscopists and manufacturers to recognize potential issues and adverse events associated with the use of rhinolaryngoscopes. It emphasizes the need for improving device reliability, training, and procedural protocols to enhance patient safety during diagnostic procedures.

求助全文
约1分钟内获得全文 求助全文
来源期刊
JMIR Human Factors
JMIR Human Factors Medicine-Health Informatics
CiteScore
3.40
自引率
3.70%
发文量
123
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信