Prostaglandin Intracameral Implants for Ocular Hypertension and Open-Angle Glaucoma.

IF 1.1 Q4 PHARMACOLOGY & PHARMACY
Christine M Cheng, Cameron Rehmani, Jordan Chin
{"title":"Prostaglandin Intracameral Implants for Ocular Hypertension and Open-Angle Glaucoma.","authors":"Christine M Cheng, Cameron Rehmani, Jordan Chin","doi":"10.1177/87551225251313707","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Sustained-release prostaglandin intracameral implants are new targeted treatment options for open-angle glaucoma or ocular hypertension that lower intraocular pressure (IOP) and reduce or eliminate the need for topical eye drops. <b>Objective:</b> To summarize evidence supporting prostaglandin intracameral implants for treatment of ocular hypertension or open angle glaucoma and identify patient populations most likely to benefit from these treatments. <b>Data sources:</b> A PubMed search (1/1/2016 to 10/1/2024) was conducted to identify randomized, controlled clinical trials for bimatoprost 10-μg and travoprost 75-μg intracameral implants. Manufacturer prescribing information, formulary dossiers, Food and Drug Administration (FDA) clinical reviews and glaucoma clinical treatment guidelines were also reviewed. <b>Study selection and data extraction:</b> English-language randomized controlled trials involving bimatoprost 10-μg or travoprost 75-μg intracameral implants were included. <b>Data synthesis:</b> Bimatoprost and travoprost intracameral implants demonstrated noninferior IOP reduction compared to timolol eye drops in phase 3 trials, with sustained effects up to 12 and 36 months, respectively. The FDA-approved implants are limited to a single administration to the affected eye to minimize corneal risks. The travoprost implant contains a titanium reservoir and requires surgical placement, while the bimatoprost implant is biodegradable and can be placed in a clinic setting. There are no studies directly comparing the safety and efficacy of the two intracameral implants. <b>Conclusions:</b> Prostaglandin intracameral implants are a novel approach to reducing medication burden while delivering sustained IOP reducing effects. Pharmacists should be aware of efficacy and safety considerations of these implants relative to available topical treatments for ocular hypertension or open angle glaucoma.</p>","PeriodicalId":16796,"journal":{"name":"Journal of Pharmacy Technology","volume":" ","pages":"87551225251313707"},"PeriodicalIF":1.1000,"publicationDate":"2025-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11791955/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pharmacy Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/87551225251313707","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Sustained-release prostaglandin intracameral implants are new targeted treatment options for open-angle glaucoma or ocular hypertension that lower intraocular pressure (IOP) and reduce or eliminate the need for topical eye drops. Objective: To summarize evidence supporting prostaglandin intracameral implants for treatment of ocular hypertension or open angle glaucoma and identify patient populations most likely to benefit from these treatments. Data sources: A PubMed search (1/1/2016 to 10/1/2024) was conducted to identify randomized, controlled clinical trials for bimatoprost 10-μg and travoprost 75-μg intracameral implants. Manufacturer prescribing information, formulary dossiers, Food and Drug Administration (FDA) clinical reviews and glaucoma clinical treatment guidelines were also reviewed. Study selection and data extraction: English-language randomized controlled trials involving bimatoprost 10-μg or travoprost 75-μg intracameral implants were included. Data synthesis: Bimatoprost and travoprost intracameral implants demonstrated noninferior IOP reduction compared to timolol eye drops in phase 3 trials, with sustained effects up to 12 and 36 months, respectively. The FDA-approved implants are limited to a single administration to the affected eye to minimize corneal risks. The travoprost implant contains a titanium reservoir and requires surgical placement, while the bimatoprost implant is biodegradable and can be placed in a clinic setting. There are no studies directly comparing the safety and efficacy of the two intracameral implants. Conclusions: Prostaglandin intracameral implants are a novel approach to reducing medication burden while delivering sustained IOP reducing effects. Pharmacists should be aware of efficacy and safety considerations of these implants relative to available topical treatments for ocular hypertension or open angle glaucoma.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Pharmacy Technology
Journal of Pharmacy Technology PHARMACOLOGY & PHARMACY-
CiteScore
1.50
自引率
0.00%
发文量
49
期刊介绍: For both pharmacists and technicians, jPT provides valuable information for those interested in the entire body of pharmacy practice. jPT covers new drugs, products, and equipment; therapeutic trends; organizational, legal, and educational activities; drug distribution and administration; and includes continuing education articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信