Hair EtG Testing in Combination With Measurements of PEth and EtG in Blood to Improve the Assessment of Alcohol Consumption.

IF 2.6 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS
Siân Bevan, Lolita Tsanaclis
{"title":"Hair EtG Testing in Combination With Measurements of PEth and EtG in Blood to Improve the Assessment of Alcohol Consumption.","authors":"Siân Bevan, Lolita Tsanaclis","doi":"10.1002/dta.3865","DOIUrl":null,"url":null,"abstract":"<p><p>Ethyl glucuronide detection in hair (H-EtG) effectively diagnoses long-term abstinence and differentiates between social and chronic excessive alcohol use. However, hair testing does not capture alcohol consumption within the week prior to sample collection. To address this limitation, blood tests like phosphatidylethanol (PEth) and blood ethyl glucuronide (B-EtG) are used alongside H-EtG, extending alcohol detection from minutes after drinking up to the period covered by hair. A total of 1205 cases were selected, where H-EtG was analysed in hair segments over 3 cm long, and concurrent fingertip blood samples in dried blood spots (DBSs) were analysed for PEth and B-EtG using UPLC/ESI-MS/MS with cut-offs: H-EtG = 5 pg/mg, PEth = 20 ng/mL and B-EtG = 10 ng/mL. A total of 468 (39%) cases showed H-EtG, PEth and B-EtG levels below cut-off, consistent with abstinence, while 198 (16%) were above cut-off, indicating continuous alcohol consumption. The remaining cases exhibited various patterns. B-EtG was negative in 282 cases (23%), with H-EtG and PEth detected, suggesting alcohol use but not recently. PEth was positive, but H-EtG and B-EtG were negative in 149 cases (12%), indicating alcohol use within a month, but not recently. H-EtG was positive in 78 cases (6%), with PEth and B-EtG negative, confirming recent abstinence. H-EtG was negative in 27 cases (2%), indicating no alcohol use for months, but recent consumption was confirmed by the detection of PEth and B-EtG. Only two cases (0.2%) had positive B-EtG with negative H-EtG and PEth, indicating recent alcohol use. The results confirm the value of combining H-EtG with concurrent blood testing of PEth and B-EtG, significantly enhancing drinking history assessment.</p>","PeriodicalId":160,"journal":{"name":"Drug Testing and Analysis","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2025-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drug Testing and Analysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/dta.3865","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Ethyl glucuronide detection in hair (H-EtG) effectively diagnoses long-term abstinence and differentiates between social and chronic excessive alcohol use. However, hair testing does not capture alcohol consumption within the week prior to sample collection. To address this limitation, blood tests like phosphatidylethanol (PEth) and blood ethyl glucuronide (B-EtG) are used alongside H-EtG, extending alcohol detection from minutes after drinking up to the period covered by hair. A total of 1205 cases were selected, where H-EtG was analysed in hair segments over 3 cm long, and concurrent fingertip blood samples in dried blood spots (DBSs) were analysed for PEth and B-EtG using UPLC/ESI-MS/MS with cut-offs: H-EtG = 5 pg/mg, PEth = 20 ng/mL and B-EtG = 10 ng/mL. A total of 468 (39%) cases showed H-EtG, PEth and B-EtG levels below cut-off, consistent with abstinence, while 198 (16%) were above cut-off, indicating continuous alcohol consumption. The remaining cases exhibited various patterns. B-EtG was negative in 282 cases (23%), with H-EtG and PEth detected, suggesting alcohol use but not recently. PEth was positive, but H-EtG and B-EtG were negative in 149 cases (12%), indicating alcohol use within a month, but not recently. H-EtG was positive in 78 cases (6%), with PEth and B-EtG negative, confirming recent abstinence. H-EtG was negative in 27 cases (2%), indicating no alcohol use for months, but recent consumption was confirmed by the detection of PEth and B-EtG. Only two cases (0.2%) had positive B-EtG with negative H-EtG and PEth, indicating recent alcohol use. The results confirm the value of combining H-EtG with concurrent blood testing of PEth and B-EtG, significantly enhancing drinking history assessment.

毛发EtG检测与血液中PEth和EtG测量相结合以改善对酒精消耗的评估。
头发中葡萄糖醛酸乙酯检测(H-EtG)可有效诊断长期戒酒并区分社会性和慢性过度饮酒。然而,头发测试不能捕捉到样本采集前一周的酒精消耗量。为了解决这一限制,血液检测如磷脂酰乙醇(PEth)和血葡萄糖醛酸乙酯(B-EtG)与H-EtG一起使用,将酒精检测从饮酒后的几分钟延长到头发覆盖的时间。选取1205例患者,在3 cm以上的毛段中检测H-EtG,同时在干血斑(dbs)中采集指尖血样,采用UPLC/ESI-MS/MS检测PEth和B-EtG,截止值为H-EtG = 5 pg/mg, PEth = 20 ng/mL, B-EtG = 10 ng/mL。共有468例(39%)患者显示H-EtG、PEth和B-EtG水平低于临界值,与戒酒一致,而198例(16%)高于临界值,表明持续饮酒。其余病例表现出不同的模式。282例(23%)患者B-EtG呈阴性,H-EtG和PEth检出,提示有饮酒史,但近期未见。149例(12%)患者检测出PEth阳性,但H-EtG和B-EtG呈阴性,表明一个月内饮酒,但近期未饮酒。78例(6%)H-EtG阳性,PEth和B-EtG阴性,证实近期禁欲。27例(2%)患者H-EtG呈阴性,表明数月未饮酒,但通过检测PEth和B-EtG证实近期饮酒。只有2例(0.2%)B-EtG阳性,H-EtG和PEth阴性,表明近期饮酒。结果证实了H-EtG联合血液PEth和B-EtG同时检测的价值,显著增强了饮酒史的评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Drug Testing and Analysis
Drug Testing and Analysis BIOCHEMICAL RESEARCH METHODS-CHEMISTRY, ANALYTICAL
CiteScore
5.90
自引率
24.10%
发文量
191
审稿时长
2.3 months
期刊介绍: As the incidence of drugs escalates in 21st century living, their detection and analysis have become increasingly important. Sport, the workplace, crime investigation, homeland security, the pharmaceutical industry and the environment are just some of the high profile arenas in which analytical testing has provided an important investigative tool for uncovering the presence of extraneous substances. In addition to the usual publishing fare of primary research articles, case reports and letters, Drug Testing and Analysis offers a unique combination of; ‘How to’ material such as ‘Tutorials’ and ‘Reviews’, Speculative pieces (‘Commentaries’ and ‘Perspectives'', providing a broader scientific and social context to the aspects of analytical testing), ‘Annual banned substance reviews’ (delivering a critical evaluation of the methods used in the characterization of established and newly outlawed compounds). Rather than focus on the application of a single technique, Drug Testing and Analysis employs a unique multidisciplinary approach to the field of controversial compound determination. Papers discussing chromatography, mass spectrometry, immunological approaches, 1D/2D gel electrophoresis, to name just a few select methods, are welcomed where their application is related to any of the six key topics listed below.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信