Intelligent islanding detection in smart microgrids using variance autocorrelation function-based modal current envelope

IF 2.4 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC
IET Smart Grid Pub Date : 2024-12-05 DOI:10.1049/stg2.12197
Shanzah Naseem, Sadiq Ahmad, Saddam Aziz, Muhammad Ali, Kazi N. Hasan, Ayaz Ahmad, Abdullah Shoukat
{"title":"Intelligent islanding detection in smart microgrids using variance autocorrelation function-based modal current envelope","authors":"Shanzah Naseem,&nbsp;Sadiq Ahmad,&nbsp;Saddam Aziz,&nbsp;Muhammad Ali,&nbsp;Kazi N. Hasan,&nbsp;Ayaz Ahmad,&nbsp;Abdullah Shoukat","doi":"10.1049/stg2.12197","DOIUrl":null,"url":null,"abstract":"<p>Islanding detection is a critical issue in grid-connected distributed microgrid systems. Distributed generation in the current power system has caused many challenges. Consequently, detecting quick and effective islanding is the most critical issue to minimise equipment failure, avoid danger, and maintain grid safety. There are various techniques for islanding identification in microgrids. Three classifications have been applied to categorise these strategies, which are: active, passive, and hybrid. This paper proposes and demonstrates an efficient and accurate approach to islanding detection based on the Variance Autocorrelation Function of a Modal Current Envelope (VAMCE) technique. Demodulation techniques including synchronous real demodulation, square law demodulation, asynchronous complex square law demodulation, and the quadrature demodulation technique are employed to detect the envelope of the 3-phase current signal. The VAMCE methodology is better suited for islanding detection because of its response to current sensitivity under islanding scenarios but not under normal conditions. Several simulations under various settings, including normal and islanded scenarios are used to analyse this method. These simulations have demonstrated different situations, such as when the system works normally and when it does not. The VAMCE along with the quadrature demodulation technique outperforms the others. The proposed solution is not only more accurate but also much faster compared to other methods. The proposed approach can identify normal and islanded situations in just 0.4 s.</p>","PeriodicalId":36490,"journal":{"name":"IET Smart Grid","volume":"7 6","pages":"1019-1035"},"PeriodicalIF":2.4000,"publicationDate":"2024-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/stg2.12197","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IET Smart Grid","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/stg2.12197","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Islanding detection is a critical issue in grid-connected distributed microgrid systems. Distributed generation in the current power system has caused many challenges. Consequently, detecting quick and effective islanding is the most critical issue to minimise equipment failure, avoid danger, and maintain grid safety. There are various techniques for islanding identification in microgrids. Three classifications have been applied to categorise these strategies, which are: active, passive, and hybrid. This paper proposes and demonstrates an efficient and accurate approach to islanding detection based on the Variance Autocorrelation Function of a Modal Current Envelope (VAMCE) technique. Demodulation techniques including synchronous real demodulation, square law demodulation, asynchronous complex square law demodulation, and the quadrature demodulation technique are employed to detect the envelope of the 3-phase current signal. The VAMCE methodology is better suited for islanding detection because of its response to current sensitivity under islanding scenarios but not under normal conditions. Several simulations under various settings, including normal and islanded scenarios are used to analyse this method. These simulations have demonstrated different situations, such as when the system works normally and when it does not. The VAMCE along with the quadrature demodulation technique outperforms the others. The proposed solution is not only more accurate but also much faster compared to other methods. The proposed approach can identify normal and islanded situations in just 0.4 s.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
IET Smart Grid
IET Smart Grid Computer Science-Computer Networks and Communications
CiteScore
6.70
自引率
4.30%
发文量
41
审稿时长
29 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信