Innovative balloon-inflatable venous cannula for enhanced cardiopulmonary bypass in minimally invasive cardiac surgery.

0 CARDIAC & CARDIOVASCULAR SYSTEMS
Faizus Sazzad, Ki Han Kim, Irwan Shah Bin Mohd Moideen, Abdulrahman El Gohary, John C Stevens, Theo Kofidis
{"title":"Innovative balloon-inflatable venous cannula for enhanced cardiopulmonary bypass in minimally invasive cardiac surgery.","authors":"Faizus Sazzad, Ki Han Kim, Irwan Shah Bin Mohd Moideen, Abdulrahman El Gohary, John C Stevens, Theo Kofidis","doi":"10.1093/icvts/ivaf017","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Minimally invasive cardiac surgery (MICS) struggles with effective caval isolation and cannulation for cardiopulmonary bypass (CPB). We aimed to develop a novel MICS venous cannula, eliminating external manipulations. The goal of this study is to thoroughly evaluate both the safety and the efficacy of a newly developed venous cannula.</p><p><strong>Methods: </strong>The study presents the Aulus venous cannula for MICS, designed with internal balloons to block caval blood flow. Preclinical bench tests with a cardiac biosimulator and large animal studies per ISO10993-2016, evaluated performance and safety.</p><p><strong>Results: </strong>The heparin-coated Aulus cannula had a post-sterilization comparable density of ∼0.200 μg/cm2. In ex vivo tests, using porcine heart models, the cannula enabled full caval occlusion, with endoscopic views confirming precise positioning. The pressure drop remained below the haemolytic threshold of 100 mmHg, indicated lower values compared to BioMedicus. A non-Good Laboratory Practice (GLP) large animal study included eight ovine models, divided into short- and long-term follow-up groups. Clinical pathology values were consistent CPB procedures, and histopathology indicated favourable tolerance despite short-term vessel injuries and long-term stenosis with fibrosis.</p><p><strong>Conclusions: </strong>The Aulus cannula showed effective anticoagulant activity, strong integrity, and good tolerance in vitro and in vivo, highlighting its clinical potential.</p>","PeriodicalId":73406,"journal":{"name":"Interdisciplinary cardiovascular and thoracic surgery","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11829808/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interdisciplinary cardiovascular and thoracic surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/icvts/ivaf017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Minimally invasive cardiac surgery (MICS) struggles with effective caval isolation and cannulation for cardiopulmonary bypass (CPB). We aimed to develop a novel MICS venous cannula, eliminating external manipulations. The goal of this study is to thoroughly evaluate both the safety and the efficacy of a newly developed venous cannula.

Methods: The study presents the Aulus venous cannula for MICS, designed with internal balloons to block caval blood flow. Preclinical bench tests with a cardiac biosimulator and large animal studies per ISO10993-2016, evaluated performance and safety.

Results: The heparin-coated Aulus cannula had a post-sterilization comparable density of ∼0.200 μg/cm2. In ex vivo tests, using porcine heart models, the cannula enabled full caval occlusion, with endoscopic views confirming precise positioning. The pressure drop remained below the haemolytic threshold of 100 mmHg, indicated lower values compared to BioMedicus. A non-Good Laboratory Practice (GLP) large animal study included eight ovine models, divided into short- and long-term follow-up groups. Clinical pathology values were consistent CPB procedures, and histopathology indicated favourable tolerance despite short-term vessel injuries and long-term stenosis with fibrosis.

Conclusions: The Aulus cannula showed effective anticoagulant activity, strong integrity, and good tolerance in vitro and in vivo, highlighting its clinical potential.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信