Enhancing mass analysis of ultra-high molecular weight polystyrene: a comparative study of copper and silver salts with MALDI mass spectrometry†

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Avinash A. Patil, Thị Khánh Ly Lại, Ching-Chieh Lee, Yi-Pang Chiu, Zhe-Xuan Liu, Che-Jen Lin and Wen-Ping Peng
{"title":"Enhancing mass analysis of ultra-high molecular weight polystyrene: a comparative study of copper and silver salts with MALDI mass spectrometry†","authors":"Avinash A. Patil, Thị Khánh Ly Lại, Ching-Chieh Lee, Yi-Pang Chiu, Zhe-Xuan Liu, Che-Jen Lin and Wen-Ping Peng","doi":"10.1039/D4AY02077D","DOIUrl":null,"url":null,"abstract":"<p >This study presents a report on the use of copper (Cu) salts in polymer mass spectrometry for samples exceeding several thousand daltons, demonstrating their efficiency and cost-effectiveness for analyzing ultra-high molecular weight (UHMW) polystyrene (PS). Using matrix-assisted laser desorption/ionization (MALDI) coupled with a home-built linear ion trap mass spectrometer (LIT-MS) under optimized conditions, polystyrene (PS) with masses up to two million daltons was successfully detected. This method using MALDI LIT-MS surpasses the previous upper detection limits observed with silver (Ag) and cesium (Cs) salts using a DCTB matrix. In the MALDI time-of-flight (TOF) mass spectrometry system, these salts were ineffective for detecting PS masses in the range from 660 kDa to 1.1 million Da, respectively (<em>Rapid Commun. Mass Spectrom.</em>, 2015, <strong>29</strong>, 1039–1046). In this study, we demonstrate for the first time that both Ag and Cu salts can successfully analyze UHMW PS samples up to 2 million Da using the <em>trans</em>-2-[3-(4-<em>tert</em>-butylphenyl)-2-methyl-2-propenylidene]-malononitrile (DCTB) matrix. However, Ag salts predominantly generate multiply charged state ion signals with no control over charge states. In contrast, Cu salts demonstrate superior versatility in modulating charge states, with copper(<small>I</small>) salts achieving higher charge states of up to +5 and copper(<small>II</small>) salts generating lower charge states of up to +3. This targeted control simplifies analysis and enhances the method's flexibility, making Cu salts particularly valuable for analyzing both individual PS samples and mixtures. Additionally, Cu salts are compatible with both DCTB and all-<em>trans</em>-retinoic acid (RA) matrices, with DCTB delivering superior performance. Comparative analysis with Ag salts further validates Cu salts as optimal cationizing reagents for UHMW PS analysis, offering a powerful tool for mass distribution measurements in polymer research and advancing analytical methods in this field.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":" 8","pages":" 1754-1764"},"PeriodicalIF":2.7000,"publicationDate":"2025-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/ay/d4ay02077d","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study presents a report on the use of copper (Cu) salts in polymer mass spectrometry for samples exceeding several thousand daltons, demonstrating their efficiency and cost-effectiveness for analyzing ultra-high molecular weight (UHMW) polystyrene (PS). Using matrix-assisted laser desorption/ionization (MALDI) coupled with a home-built linear ion trap mass spectrometer (LIT-MS) under optimized conditions, polystyrene (PS) with masses up to two million daltons was successfully detected. This method using MALDI LIT-MS surpasses the previous upper detection limits observed with silver (Ag) and cesium (Cs) salts using a DCTB matrix. In the MALDI time-of-flight (TOF) mass spectrometry system, these salts were ineffective for detecting PS masses in the range from 660 kDa to 1.1 million Da, respectively (Rapid Commun. Mass Spectrom., 2015, 29, 1039–1046). In this study, we demonstrate for the first time that both Ag and Cu salts can successfully analyze UHMW PS samples up to 2 million Da using the trans-2-[3-(4-tert-butylphenyl)-2-methyl-2-propenylidene]-malononitrile (DCTB) matrix. However, Ag salts predominantly generate multiply charged state ion signals with no control over charge states. In contrast, Cu salts demonstrate superior versatility in modulating charge states, with copper(I) salts achieving higher charge states of up to +5 and copper(II) salts generating lower charge states of up to +3. This targeted control simplifies analysis and enhances the method's flexibility, making Cu salts particularly valuable for analyzing both individual PS samples and mixtures. Additionally, Cu salts are compatible with both DCTB and all-trans-retinoic acid (RA) matrices, with DCTB delivering superior performance. Comparative analysis with Ag salts further validates Cu salts as optimal cationizing reagents for UHMW PS analysis, offering a powerful tool for mass distribution measurements in polymer research and advancing analytical methods in this field.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信