Fractal correlation properties of heart rate variability and respiratory frequency as measures of endurance exercise durability.

IF 2.8 3区 医学 Q2 PHYSIOLOGY
Bruce Rogers, Pablo R Fleitas-Paniagua, Mackenzie Trpcic, Alessandro M Zagatto, Juan M Murias
{"title":"Fractal correlation properties of heart rate variability and respiratory frequency as measures of endurance exercise durability.","authors":"Bruce Rogers, Pablo R Fleitas-Paniagua, Mackenzie Trpcic, Alessandro M Zagatto, Juan M Murias","doi":"10.1007/s00421-025-05716-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Field-based measures of durability (exercise-related physiologic deterioration over time) for assessing athletic fitness often rely on changes in maximal power profiles or heart rate (HR) drift. This study aimed to determine whether an index of HR variability based on the short-term exponent of Detrended Fluctuation Analysis (DFA a1) along with respiratory frequency (fB) could demonstrate changes in durability during a Time to Task Failure (TTF) Trial.</p><p><strong>Methods: </strong>Ten participants performed a cycling TTF at an intensity of 95% of the respiratory compensation point (RCP) on two occasions, Control and a \"Reward\" where a monetary incentive was offered when task failure was signaled. Metabolic responses including oxygen uptake ( <math> <msub> <mrow><mover><mtext>V</mtext> <mo>˙</mo></mover> <mtext>O</mtext></mrow> <mn>2</mn></msub> </math> ), lactate and glucose along with HR, DFA a1 and fB were measured and compared over each quarter of the TTF up to the time of signaling (Q1, Q2, Q3, and Q4).</p><p><strong>Results: </strong>The elapsed time of TTF sessions was statistically similar (p = 0.54). After initial equilibration, metabolic responses remained largely stable over Q2-Q4. HR, DFA a1 and fB displayed drift over Q2-Q4 with significant ANOVA. Repeatability of quarterly HR, DFA a1, and fB between Control and Reward sessions was high with ICC between 0.73 and 0.94, Pearson's r was between 0.83 and 0.98 with no difference in mean values by paired t testing.</p><p><strong>Conclusion: </strong>HR, fB and DFA a1 are useful metrics representing alteration in physiologic characteristics demonstrating durability loss during an endurance exercise session. These measures were repeatable across sessions and have the potential to be monitored retrospectively or in real time in the field with low-cost consumer equipment.</p>","PeriodicalId":12005,"journal":{"name":"European Journal of Applied Physiology","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2025-02-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Applied Physiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00421-025-05716-2","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Field-based measures of durability (exercise-related physiologic deterioration over time) for assessing athletic fitness often rely on changes in maximal power profiles or heart rate (HR) drift. This study aimed to determine whether an index of HR variability based on the short-term exponent of Detrended Fluctuation Analysis (DFA a1) along with respiratory frequency (fB) could demonstrate changes in durability during a Time to Task Failure (TTF) Trial.

Methods: Ten participants performed a cycling TTF at an intensity of 95% of the respiratory compensation point (RCP) on two occasions, Control and a "Reward" where a monetary incentive was offered when task failure was signaled. Metabolic responses including oxygen uptake ( V ˙ O 2 ), lactate and glucose along with HR, DFA a1 and fB were measured and compared over each quarter of the TTF up to the time of signaling (Q1, Q2, Q3, and Q4).

Results: The elapsed time of TTF sessions was statistically similar (p = 0.54). After initial equilibration, metabolic responses remained largely stable over Q2-Q4. HR, DFA a1 and fB displayed drift over Q2-Q4 with significant ANOVA. Repeatability of quarterly HR, DFA a1, and fB between Control and Reward sessions was high with ICC between 0.73 and 0.94, Pearson's r was between 0.83 and 0.98 with no difference in mean values by paired t testing.

Conclusion: HR, fB and DFA a1 are useful metrics representing alteration in physiologic characteristics demonstrating durability loss during an endurance exercise session. These measures were repeatable across sessions and have the potential to be monitored retrospectively or in real time in the field with low-cost consumer equipment.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.00
自引率
6.70%
发文量
227
审稿时长
3 months
期刊介绍: The European Journal of Applied Physiology (EJAP) aims to promote mechanistic advances in human integrative and translational physiology. Physiology is viewed broadly, having overlapping context with related disciplines such as biomechanics, biochemistry, endocrinology, ergonomics, immunology, motor control, and nutrition. EJAP welcomes studies dealing with physical exercise, training and performance. Studies addressing physiological mechanisms are preferred over descriptive studies. Papers dealing with animal models or pathophysiological conditions are not excluded from consideration, but must be clearly relevant to human physiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信