Comparison of nanosecond and femtosecond laser-induced breakdown spectroscopy for determination of U and Th in tantalum–niobium ores

IF 3.1 2区 化学 Q2 CHEMISTRY, ANALYTICAL
Xiaoliang Liu, Shichao Ren, Ming Zhang, Lingling Peng, Ye Zhang, Xiangting Meng, Shujia Wu, Yuhong Li, Lin Liu and Shaohua Sun
{"title":"Comparison of nanosecond and femtosecond laser-induced breakdown spectroscopy for determination of U and Th in tantalum–niobium ores","authors":"Xiaoliang Liu, Shichao Ren, Ming Zhang, Lingling Peng, Ye Zhang, Xiangting Meng, Shujia Wu, Yuhong Li, Lin Liu and Shaohua Sun","doi":"10.1039/D4JA00268G","DOIUrl":null,"url":null,"abstract":"<p >The measurement of uranium (U) and thorium (Th) is a critical step in the mining process of tantalum–niobium (Ta–Nb) ores. However, the quantitative analysis of high-Z (atomic number) elements in U polymetallic ores by laser-induced breakdown spectroscopy (LIBS) is usually very difficult because of their complex spectra. To overcome this limitation, a comparison of the quantitative analysis capability between nanosecond LIBS (ns-LIBS) and femtosecond LIBS (fs-LIBS) was performed in this study. A multivariate calibration method based on the partial least squares regression (PLSR) algorithm was coupled with LIBS to solve the interference of the analytical lines and enhance the performance of LIBS analysis. Due to the different excitation sources, ns-LIBS and fs-LIBS exhibit significantly different spectral characteristics, thereby affecting the performance of quantitative analysis. With the assistance of data pretreatment, optimization of the number of principal component (PC) procedures and the selection of the spectral region, the performance of U and Th determination for both ns-LIBS and fs-LIBS was provided by the PLSR algorithm. Compared to ns-LIBS, fs-LIBS provided enhanced predictive capability and accuracy, with the root mean square error of calibration (RMSEC) decreased from 56 ppm to 30 ppm for U and from 192 ppm to 175 ppm for Th, the fitting coefficients (<em>R</em><small><sup>2</sup></small>) increased from 0.9859 to 0.9959 for U and from 0.9989 to 0.9991 for Th, and all mean relative errors (MREs), root mean square errors of prediction (RMSEPs) and most of the relative standard deviations (RSDs) for U and Th improved for three validation samples. The results illustrate that fs-LIBS combined with PLSR can effectively enhance the accuracy of U and Th determination in Ta–Nb ores.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 2","pages":" 437-446"},"PeriodicalIF":3.1000,"publicationDate":"2024-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/ja/d4ja00268g","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The measurement of uranium (U) and thorium (Th) is a critical step in the mining process of tantalum–niobium (Ta–Nb) ores. However, the quantitative analysis of high-Z (atomic number) elements in U polymetallic ores by laser-induced breakdown spectroscopy (LIBS) is usually very difficult because of their complex spectra. To overcome this limitation, a comparison of the quantitative analysis capability between nanosecond LIBS (ns-LIBS) and femtosecond LIBS (fs-LIBS) was performed in this study. A multivariate calibration method based on the partial least squares regression (PLSR) algorithm was coupled with LIBS to solve the interference of the analytical lines and enhance the performance of LIBS analysis. Due to the different excitation sources, ns-LIBS and fs-LIBS exhibit significantly different spectral characteristics, thereby affecting the performance of quantitative analysis. With the assistance of data pretreatment, optimization of the number of principal component (PC) procedures and the selection of the spectral region, the performance of U and Th determination for both ns-LIBS and fs-LIBS was provided by the PLSR algorithm. Compared to ns-LIBS, fs-LIBS provided enhanced predictive capability and accuracy, with the root mean square error of calibration (RMSEC) decreased from 56 ppm to 30 ppm for U and from 192 ppm to 175 ppm for Th, the fitting coefficients (R2) increased from 0.9859 to 0.9959 for U and from 0.9989 to 0.9991 for Th, and all mean relative errors (MREs), root mean square errors of prediction (RMSEPs) and most of the relative standard deviations (RSDs) for U and Th improved for three validation samples. The results illustrate that fs-LIBS combined with PLSR can effectively enhance the accuracy of U and Th determination in Ta–Nb ores.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信