Rapid determination of iodide ion content in chloride molten salt by ascorbic acid reduction

IF 3.1 2区 化学 Q2 CHEMISTRY, ANALYTICAL
Ming Cheng, Junxia Geng, Haixia Cong, Qiang Dou and Haiying Fu
{"title":"Rapid determination of iodide ion content in chloride molten salt by ascorbic acid reduction","authors":"Ming Cheng, Junxia Geng, Haixia Cong, Qiang Dou and Haiying Fu","doi":"10.1039/D4JA00242C","DOIUrl":null,"url":null,"abstract":"<p >This study aimed to establish an alternative method for assessing the efficacy of removing fission product iodine from molten salt spent nuclear fuel under acidic conditions. In the pretreatment stage, ascorbic acid with a mass fraction of 0.5 wt% was used instead of dilute nitric acid with a volume fraction less than 2 vol%. The iodide content of molten salt samples dissolved in various ratios of Cl<small><sup>−</sup></small> to I<small><sup>−</sup></small> was determined and compared by inductively coupled plasma mass spectrometry (ICP-MS) and ion chromatography (IC). The iodide ions in simulated chloride salts containing LiI were tested after pretreatment. It was found that at 1.0 mg L<small><sup>−1</sup></small> chloride ion concentration, the detection limit of this method was 0.255 μg L<small><sup>−1</sup></small>, with a spike-and-recovery experience between 103.3% and 102.8% and a relative standard deviation of less than 3% (<em>n</em> = 6). The average spike-and-recovery experience was 104.3%, and the limit of detection was 0.472 μg L<small><sup>−1</sup></small> at a concentration of 100.0 mg L<small><sup>−1</sup></small> with RSD of less than 5%. When the concentration ratio of Cl<small><sup>−</sup></small>/I<small><sup>−</sup></small> in the molten salt was less than two orders of magnitude, the analytical value of this technique was comparable to the measurement result by IC. Furthermore, the accuracy of ICP-MS was superior to that of IC when the concentration ratio of Cl<small><sup>−</sup></small>/I<small><sup>−</sup></small> was higher than two orders of magnitude. The results indicate that the improved pretreatment method with ascorbic acid can eliminate inaccuracies caused by the iodide memory effect. The method has been verified to determine iodide content in high chloride molten salt under acidic conditions and will be used in the treatment of spent fuel from molten salt reactors.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 2","pages":" 429-436"},"PeriodicalIF":3.1000,"publicationDate":"2024-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/ja/d4ja00242c","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study aimed to establish an alternative method for assessing the efficacy of removing fission product iodine from molten salt spent nuclear fuel under acidic conditions. In the pretreatment stage, ascorbic acid with a mass fraction of 0.5 wt% was used instead of dilute nitric acid with a volume fraction less than 2 vol%. The iodide content of molten salt samples dissolved in various ratios of Cl to I was determined and compared by inductively coupled plasma mass spectrometry (ICP-MS) and ion chromatography (IC). The iodide ions in simulated chloride salts containing LiI were tested after pretreatment. It was found that at 1.0 mg L−1 chloride ion concentration, the detection limit of this method was 0.255 μg L−1, with a spike-and-recovery experience between 103.3% and 102.8% and a relative standard deviation of less than 3% (n = 6). The average spike-and-recovery experience was 104.3%, and the limit of detection was 0.472 μg L−1 at a concentration of 100.0 mg L−1 with RSD of less than 5%. When the concentration ratio of Cl/I in the molten salt was less than two orders of magnitude, the analytical value of this technique was comparable to the measurement result by IC. Furthermore, the accuracy of ICP-MS was superior to that of IC when the concentration ratio of Cl/I was higher than two orders of magnitude. The results indicate that the improved pretreatment method with ascorbic acid can eliminate inaccuracies caused by the iodide memory effect. The method has been verified to determine iodide content in high chloride molten salt under acidic conditions and will be used in the treatment of spent fuel from molten salt reactors.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信