{"title":"Optimization and greenness assessments of the supramolecular solvent-assisted cloud point extraction method for copper spectrophotometric determination in water and food samples","authors":"Ekhlas A. AbdulKareem ,&nbsp;Azhar Y.M. Al-Murshedi ,&nbsp;Rana Kadhim Ridha ,&nbsp;Ebaa Adnan Azooz","doi":"10.1016/j.greeac.2024.100181","DOIUrl":null,"url":null,"abstract":"<div><div>For the first time, the green supramolecular solvents (SUPRASs)-based cloud point extraction (CPE) approach was created for copper spectrophotometric determination in food and water samples. SUPRASs were synthesized in six different forms and used as synergistic reagents. SUPRAS (water, salicylic acid, and THF) mixed with TritonX-114 (TX-114) to be the most efficient extraction solvent. The validation investigation found that the linearity range, limit of detection (LOD), limit of quantification (LOQ), enhancement factor (EF), and preconcentration factor (PF) are 0.2-700.0 μg L<sup>-1</sup>, 0.1 μg L<sup>-1</sup>, 0.33 μg L<sup>-1</sup>, 85.0, and 50.0, respectively. The technique's accuracy was calculated using standard reference materials (SRMs) (GBW07605 Tea Leaves and GBW10019 Apple) and ranged between 96.0 and 98.9%. Lastly, a novel SUPRAS-CPE approach was utilized to determine copper concentrations in real water, food tests, and SRMs. Furthermore, the SUPRAS-CPE conforms to green chemistry principles by using less both time and energy than previous studies. Also, the greenness values were determined by three recent tools. The Analytical Greenness Metric for Sample Preparation (AGREEprep), Complex Modified GAPI (ComplexMoGAPI), and Sample Preparation Metric of Sustainability (SPMS) programs produced results of 0.79, 86.0, and 8.42, respectively. These results are strongly aligned with both green ideals and environmentally friendly practices. The finding increases the possibilities for using SUPRAS-CPE to extract additional mineral ions.</div></div>","PeriodicalId":100594,"journal":{"name":"Green Analytical Chemistry","volume":"11 ","pages":"Article 100181"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Green Analytical Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772577424000909","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

For the first time, the green supramolecular solvents (SUPRASs)-based cloud point extraction (CPE) approach was created for copper spectrophotometric determination in food and water samples. SUPRASs were synthesized in six different forms and used as synergistic reagents. SUPRAS (water, salicylic acid, and THF) mixed with TritonX-114 (TX-114) to be the most efficient extraction solvent. The validation investigation found that the linearity range, limit of detection (LOD), limit of quantification (LOQ), enhancement factor (EF), and preconcentration factor (PF) are 0.2-700.0 μg L-1, 0.1 μg L-1, 0.33 μg L-1, 85.0, and 50.0, respectively. The technique's accuracy was calculated using standard reference materials (SRMs) (GBW07605 Tea Leaves and GBW10019 Apple) and ranged between 96.0 and 98.9%. Lastly, a novel SUPRAS-CPE approach was utilized to determine copper concentrations in real water, food tests, and SRMs. Furthermore, the SUPRAS-CPE conforms to green chemistry principles by using less both time and energy than previous studies. Also, the greenness values were determined by three recent tools. The Analytical Greenness Metric for Sample Preparation (AGREEprep), Complex Modified GAPI (ComplexMoGAPI), and Sample Preparation Metric of Sustainability (SPMS) programs produced results of 0.79, 86.0, and 8.42, respectively. These results are strongly aligned with both green ideals and environmentally friendly practices. The finding increases the possibilities for using SUPRAS-CPE to extract additional mineral ions.

Abstract Image

超分子溶剂辅助浊点萃取法测定水和食品样品中铜的优化及绿度评价
首次建立了基于绿色超分子溶剂(SUPRASs)的云点萃取(CPE)方法,用于食品和水样中铜的分光光度测定。合成了6种不同形式的SUPRASs,并作为增效试剂使用。SUPRAS(水,水杨酸和THF)与TritonX-114 (TX-114)混合是最有效的萃取溶剂。验证结果表明,该方法的线性范围为0.2 ~ 700.0 μg L-1,检出限为0.1 μg L-1,定量限为0.33 μg L-1,增强因子为85.0,预富集因子为50.0。使用标准对照品(GBW07605茶叶和GBW10019苹果)计算该技术的准确度在96.0 ~ 98.9%之间。最后,一种新的supra - cpe方法被用于确定实际水、食品测试和srm中的铜浓度。此外,supra - cpe符合绿色化学原则,比以前的研究使用更少的时间和能量。此外,绿色值是由三个最新的工具确定的。样品制备的分析性绿色指标(AGREEprep)、复合修饰GAPI (ComplexMoGAPI)和可持续性样品制备指标(SPMS)程序的结果分别为0.79、86.0和8.42。这些结果与绿色理想和环境友好型实践非常一致。这一发现增加了使用supra - cpe提取额外矿物离子的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.00
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信