{"title":"Technoeconomic assessment of a solar-driven adsorption-based space conditioning system for low-energy multi-unit residential buildings in canada","authors":"Colin Ward,&nbsp;Jean Duquette,&nbsp;Cynthia A. Cruickshank","doi":"10.1016/j.applthermaleng.2025.125739","DOIUrl":null,"url":null,"abstract":"<div><div>Building energy demands and associated greenhouse gas emissions are increasing in Canada. A potential pathway to counteract this trend involves moving away from carbon intensive fossil fuel and electricity driven space conditioning technologies like furnaces and vapour compression air conditioners towards more sustainable solar heating and cooling technologies. This study evaluates the technoeconomic and environmental performance of a solar-driven adsorption-based system used to meet the space conditioning and domestic hot water demands of a low-energy multi-unit residential building in Canada. A transient numerical model of the building and proposed system is developed in the TRNSYS environment. The following two reference systems are also modeled for comparison: 1) a modern system that uses unit-level mini-split heat pumps for space heating and cooling, and a centralized electric domestic hot water tank for water heating; and 2) a centralized system that uses natural gas for space and water heating, and a vapour compression chiller for space cooling. Results from annual simulations in 12 Canadian locations show that the proposed system can achieve solar fractions greater than 0.8 in certain areas (<em>e.g.,</em> the cities of Winnipeg and Ottawa) and can reduce annual greenhouse gas emissions by up to 62.7% and 99.8% (in the city of Winnipeg) relative to the all-electric unit-level heat pump and centralized natural gas reference systems, respectively. While the levelized cost of energy for the proposed system is high, a compelling economic argument can be made in jurisdictions with fossil fuel dependent electrical grids.</div></div>","PeriodicalId":8201,"journal":{"name":"Applied Thermal Engineering","volume":"267 ","pages":"Article 125739"},"PeriodicalIF":6.1000,"publicationDate":"2025-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Thermal Engineering","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1359431125003308","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

Building energy demands and associated greenhouse gas emissions are increasing in Canada. A potential pathway to counteract this trend involves moving away from carbon intensive fossil fuel and electricity driven space conditioning technologies like furnaces and vapour compression air conditioners towards more sustainable solar heating and cooling technologies. This study evaluates the technoeconomic and environmental performance of a solar-driven adsorption-based system used to meet the space conditioning and domestic hot water demands of a low-energy multi-unit residential building in Canada. A transient numerical model of the building and proposed system is developed in the TRNSYS environment. The following two reference systems are also modeled for comparison: 1) a modern system that uses unit-level mini-split heat pumps for space heating and cooling, and a centralized electric domestic hot water tank for water heating; and 2) a centralized system that uses natural gas for space and water heating, and a vapour compression chiller for space cooling. Results from annual simulations in 12 Canadian locations show that the proposed system can achieve solar fractions greater than 0.8 in certain areas (e.g., the cities of Winnipeg and Ottawa) and can reduce annual greenhouse gas emissions by up to 62.7% and 99.8% (in the city of Winnipeg) relative to the all-electric unit-level heat pump and centralized natural gas reference systems, respectively. While the levelized cost of energy for the proposed system is high, a compelling economic argument can be made in jurisdictions with fossil fuel dependent electrical grids.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Applied Thermal Engineering
Applied Thermal Engineering 工程技术-工程:机械
CiteScore
11.30
自引率
15.60%
发文量
1474
审稿时长
57 days
期刊介绍: Applied Thermal Engineering disseminates novel research related to the design, development and demonstration of components, devices, equipment, technologies and systems involving thermal processes for the production, storage, utilization and conservation of energy, with a focus on engineering application. The journal publishes high-quality and high-impact Original Research Articles, Review Articles, Short Communications and Letters to the Editor on cutting-edge innovations in research, and recent advances or issues of interest to the thermal engineering community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信