Inflow-to-Outflow Stent Frame Expansion, Ellipticity, and Decoupling in Evolut TAVR: Implications for Mid-term Hemodynamic Performance

Rishi Puri MD, PhD , Julianne Spencer PhD , Didier Tchétché MD , Nicolas M. Van Mieghem MD, PhD , John K. Forrest MD , Michael J. Reardon MD , Jorge Zhingre Sanchez PhD , Andres Caballero PhD , Philipp Blanke MD , Jonathon A. Leipsic MD , Paul Sorajja MD , G. Michael Deeb MD , Shinichi Fukuhara MD , Lindsay M. Lucas MSc , Taofik Oyekunle MSc , Gilbert H.L. Tang MD, MSc, MBA
{"title":"Inflow-to-Outflow Stent Frame Expansion, Ellipticity, and Decoupling in Evolut TAVR: Implications for Mid-term Hemodynamic Performance","authors":"Rishi Puri MD, PhD ,&nbsp;Julianne Spencer PhD ,&nbsp;Didier Tchétché MD ,&nbsp;Nicolas M. Van Mieghem MD, PhD ,&nbsp;John K. Forrest MD ,&nbsp;Michael J. Reardon MD ,&nbsp;Jorge Zhingre Sanchez PhD ,&nbsp;Andres Caballero PhD ,&nbsp;Philipp Blanke MD ,&nbsp;Jonathon A. Leipsic MD ,&nbsp;Paul Sorajja MD ,&nbsp;G. Michael Deeb MD ,&nbsp;Shinichi Fukuhara MD ,&nbsp;Lindsay M. Lucas MSc ,&nbsp;Taofik Oyekunle MSc ,&nbsp;Gilbert H.L. Tang MD, MSc, MBA","doi":"10.1016/j.jscai.2024.102448","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>The native aortic annulus for self-expanding transcatheter aortic valve replacement (TAVR) has variable ellipticity. A noncircular and underexpanded transcatheter aortic valve (TAV) may impact hemodynamic performance. This study aimed to quantify Evolut TAV (Medtronic) frame ellipticity and expansion 30 days post-TAVR and evaluate their impact on 1-year hypoattenuating leaflet thickening and 4-year hemodynamics.</div></div><div><h3>Methods</h3><div>We retrospectively evaluated 184 patients from the Evolut Low Risk substudy with high-quality computed tomography images. Frame ellipticity ratio and percent expansion were quantified at each frame node level 30 days after TAVR. Variables associated with frame deformation, 1-year hypoattenuating leaflet thickening, and 4-year hemodynamics were identified.</div></div><div><h3>Results</h3><div>Mean Evolut frame ellipticity was highest at the inflow (1.18 ± 0.08) and lowest at the functional leaflet region (1.05 ± 0.03) and frame outflow (1.04 ± 0.03). Frame expansion was lowest at the inflow (83.8% ± 4.9%) and highest at the functional leaflet region (97.8% ± 1.7%). TAV frame circularity and expansion significantly increased from the annular level to the leaflet region (<em>P</em> &lt; .001). Mean gradient, effective orifice area, and paravalvular regurgitation at 4 years were not affected by Evolut TAV's relative noncircularity and underexpansion at the frame inflow. Frame underexpansion at the leaflet region, however, was associated with a smaller effective orifice area at 4 years.</div></div><div><h3>Conclusions</h3><div>Evolut frame deformation at the inflow did not affect the circularity and expansion of the stent at the functional leaflet region. Mid-term (4-year) Evolut hemodynamic performance does not appear to be impacted by frame inflow geometry.</div></div>","PeriodicalId":73990,"journal":{"name":"Journal of the Society for Cardiovascular Angiography & Interventions","volume":"4 1","pages":"Article 102448"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Society for Cardiovascular Angiography & Interventions","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772930324021379","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background

The native aortic annulus for self-expanding transcatheter aortic valve replacement (TAVR) has variable ellipticity. A noncircular and underexpanded transcatheter aortic valve (TAV) may impact hemodynamic performance. This study aimed to quantify Evolut TAV (Medtronic) frame ellipticity and expansion 30 days post-TAVR and evaluate their impact on 1-year hypoattenuating leaflet thickening and 4-year hemodynamics.

Methods

We retrospectively evaluated 184 patients from the Evolut Low Risk substudy with high-quality computed tomography images. Frame ellipticity ratio and percent expansion were quantified at each frame node level 30 days after TAVR. Variables associated with frame deformation, 1-year hypoattenuating leaflet thickening, and 4-year hemodynamics were identified.

Results

Mean Evolut frame ellipticity was highest at the inflow (1.18 ± 0.08) and lowest at the functional leaflet region (1.05 ± 0.03) and frame outflow (1.04 ± 0.03). Frame expansion was lowest at the inflow (83.8% ± 4.9%) and highest at the functional leaflet region (97.8% ± 1.7%). TAV frame circularity and expansion significantly increased from the annular level to the leaflet region (P < .001). Mean gradient, effective orifice area, and paravalvular regurgitation at 4 years were not affected by Evolut TAV's relative noncircularity and underexpansion at the frame inflow. Frame underexpansion at the leaflet region, however, was associated with a smaller effective orifice area at 4 years.

Conclusions

Evolut frame deformation at the inflow did not affect the circularity and expansion of the stent at the functional leaflet region. Mid-term (4-year) Evolut hemodynamic performance does not appear to be impacted by frame inflow geometry.
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.40
自引率
0.00%
发文量
0
审稿时长
48 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信