{"title":"Bridging the gap to clinical use: A systematic review on TMS–EEG test-retest reliability","authors":"Giacomo Bertazzoli ,&nbsp;Elisa Dognini ,&nbsp;Peter J. Fried ,&nbsp;Carlo Miniussi ,&nbsp;Petro Julkunen ,&nbsp;Marta Bortoletto","doi":"10.1016/j.clinph.2025.01.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Transcranial magnetic stimulation (TMS) combined with electroencephalography (EEG) can provide insight on cortical excitability and brain circuits. TMS-evoked potentials (TEPs) are phase-locked waveforms reflecting neural activity, with potential applications in psychiatry and neurology. However, the reliability of TEPs remains underexplored, hindering clinical standardization. This systematic review evaluates TEP reliability, focusing on commonly used measures and assessments.</div></div><div><h3>Methods</h3><div>A systematic review was conducted on PubMed for studies from 2002 to October 10, 2024, using keywords combining TMS, EEG, and reliability terms. Systematic reviews and non-English articles were excluded.</div></div><div><h3>Results</h3><div>Eighteen studies met inclusion criteria, mostly assessing young, healthy populations. Late TEP components demonstrated high relative reliability, while early components exhibited lower reliability and variability across sessions. Analytical methods like the intraclass and concordance correlation coefficients, and Pearson’s correlations consistently favored late TEPs.</div></div><div><h3>Discussion</h3><div>Late TEPs exhibit higher reliability, while early components require further research. TMS artifacts complicate interpretation, in both late and early responses. Formal reliability assessments, standardized protocols, and diverse populations are essential for advancing TEP reliability for clinical application.</div></div><div><h3>Conclusions</h3><div>A more comprehensive reliability assessments is needed before the implementation of clinical applications.</div></div>","PeriodicalId":10671,"journal":{"name":"Clinical Neurophysiology","volume":"171 ","pages":"Pages 133-145"},"PeriodicalIF":3.7000,"publicationDate":"2025-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Neurophysiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1388245725000112","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Transcranial magnetic stimulation (TMS) combined with electroencephalography (EEG) can provide insight on cortical excitability and brain circuits. TMS-evoked potentials (TEPs) are phase-locked waveforms reflecting neural activity, with potential applications in psychiatry and neurology. However, the reliability of TEPs remains underexplored, hindering clinical standardization. This systematic review evaluates TEP reliability, focusing on commonly used measures and assessments.

Methods

A systematic review was conducted on PubMed for studies from 2002 to October 10, 2024, using keywords combining TMS, EEG, and reliability terms. Systematic reviews and non-English articles were excluded.

Results

Eighteen studies met inclusion criteria, mostly assessing young, healthy populations. Late TEP components demonstrated high relative reliability, while early components exhibited lower reliability and variability across sessions. Analytical methods like the intraclass and concordance correlation coefficients, and Pearson’s correlations consistently favored late TEPs.

Discussion

Late TEPs exhibit higher reliability, while early components require further research. TMS artifacts complicate interpretation, in both late and early responses. Formal reliability assessments, standardized protocols, and diverse populations are essential for advancing TEP reliability for clinical application.

Conclusions

A more comprehensive reliability assessments is needed before the implementation of clinical applications.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinical Neurophysiology
Clinical Neurophysiology 医学-临床神经学
CiteScore
8.70
自引率
6.40%
发文量
932
审稿时长
59 days
期刊介绍: As of January 1999, The journal Electroencephalography and Clinical Neurophysiology, and its two sections Electromyography and Motor Control and Evoked Potentials have amalgamated to become this journal - Clinical Neurophysiology. Clinical Neurophysiology is the official journal of the International Federation of Clinical Neurophysiology, the Brazilian Society of Clinical Neurophysiology, the Czech Society of Clinical Neurophysiology, the Italian Clinical Neurophysiology Society and the International Society of Intraoperative Neurophysiology.The journal is dedicated to fostering research and disseminating information on all aspects of both normal and abnormal functioning of the nervous system. The key aim of the publication is to disseminate scholarly reports on the pathophysiology underlying diseases of the central and peripheral nervous system of human patients. Clinical trials that use neurophysiological measures to document change are encouraged, as are manuscripts reporting data on integrated neuroimaging of central nervous function including, but not limited to, functional MRI, MEG, EEG, PET and other neuroimaging modalities.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信