{"title":"Low-cost optical fiber multimode interference biosensor based on a glucose sensitive Glucose-Oxidase enzyme thin-film","authors":"W.E. Rodríguez-Rodríguez , A.J. Rodríguez-Rodríguez , A. Juárez-Saldivar , C.R. Zamarreño , I.R. Matias","doi":"10.1016/j.snr.2024.100267","DOIUrl":null,"url":null,"abstract":"<div><div>In this research we report a contribution for the development of low-cost fiber optical biosensors fabricated by the Single Mode-Multi Mode-Single Mode configuration applied for the glucose monitoring considering clinical concentrations ranges in aqueous analytes. Designed devices are evaluated using health standard detection ranges, such as healthy, pre-diabetic, and diabetic stages operating at the visible spectral region. The sensing regions has been prepared by the etching technique in order to improve the interaction between the evanescent wave with the surrounding medium followed by functionalization of enzyme oxidase glucose via the electrostatic self-assembly using by Poly(allylamine hydrochloride) as an immobilizer matrix. The increase of bilayers number over the sensor surface permits us to demonstrate the enhancement of sensitivity and limit of detection. Experimental results permitted the glucose characterization in the range from 0.3 to 2.4 mg mL-1 obtaining a response time of 9 s and a sensitivity of 1.8 nm/(mg mL-1) allowing to detect hypoglycemia and diabetes stages according to the World Health Organization standards.</div></div>","PeriodicalId":426,"journal":{"name":"Sensors and Actuators Reports","volume":"9 ","pages":"Article 100267"},"PeriodicalIF":6.5000,"publicationDate":"2024-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666053924000833","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
In this research we report a contribution for the development of low-cost fiber optical biosensors fabricated by the Single Mode-Multi Mode-Single Mode configuration applied for the glucose monitoring considering clinical concentrations ranges in aqueous analytes. Designed devices are evaluated using health standard detection ranges, such as healthy, pre-diabetic, and diabetic stages operating at the visible spectral region. The sensing regions has been prepared by the etching technique in order to improve the interaction between the evanescent wave with the surrounding medium followed by functionalization of enzyme oxidase glucose via the electrostatic self-assembly using by Poly(allylamine hydrochloride) as an immobilizer matrix. The increase of bilayers number over the sensor surface permits us to demonstrate the enhancement of sensitivity and limit of detection. Experimental results permitted the glucose characterization in the range from 0.3 to 2.4 mg mL-1 obtaining a response time of 9 s and a sensitivity of 1.8 nm/(mg mL-1) allowing to detect hypoglycemia and diabetes stages according to the World Health Organization standards.
期刊介绍:
Sensors and Actuators Reports is a peer-reviewed open access journal launched out from the Sensors and Actuators journal family. Sensors and Actuators Reports is dedicated to publishing new and original works in the field of all type of sensors and actuators, including bio-, chemical-, physical-, and nano- sensors and actuators, which demonstrates significant progress beyond the current state of the art. The journal regularly publishes original research papers, reviews, and short communications.
For research papers and short communications, the journal aims to publish the new and original work supported by experimental results and as such purely theoretical works are not accepted.