Field calibration and performance evaluation of low-cost sensors for monitoring airborne PM in the occupational mining environment

IF 3.9 3区 环境科学与生态学 Q2 ENGINEERING, CHEMICAL
Abhishek Penchala , Aditya Kumar Patra , Namrata Mishra , Samrat Santra
{"title":"Field calibration and performance evaluation of low-cost sensors for monitoring airborne PM in the occupational mining environment","authors":"Abhishek Penchala ,&nbsp;Aditya Kumar Patra ,&nbsp;Namrata Mishra ,&nbsp;Samrat Santra","doi":"10.1016/j.jaerosci.2024.106519","DOIUrl":null,"url":null,"abstract":"<div><div>Surface mining operations emit particulate matter (PM) with varying sizes and compositions, adversely affecting the health of mine workers and adjoining communities. Measurements for regulatory compliance at present are obtained by bulky instruments, which are costly and provide data averaged over a period of time. Recently, low-cost PM sensors (LCPMS) have been increasingly used in indoor and outdoor environments for monitoring real-time PM concentrations with high spatial and temporal resolution. No comprehensive study has been undertaken to evaluate the performance of LCPMS when exposed to uncontrolled high dust concentrations prevailing in the occupational mining environment. The study aimed to achieve this by deploying three sensors (OPC N3, SPS30, and SDS011) in a highly mechanized surface coal mine. A comparative assessment of these sensors has been conducted by calibrating them against a research-grade reference instrument in uncontrolled indoor, outdoor, and mining environments. The performance of OPC N3 and SPS30 sensors was found to be good, with high linearity (R<sup>2</sup> = 0.90 – 0.99) and precision (CV = 2 – 6%). Incorporating the monitored local meteorological conditions and PM proportions improved the performance of the applied calibration models. The decision tree-based regression model performed better (R<sup>2</sup> = 0.95 – 99; RMSE = 0.8 – 11.4; MAE = 0.4 – 5.3) compared to the multiple linear model in accurately predicting reference equivalent PM mass concentration measurements. The comprehensive performance evaluation of LCPMS in this study highlights its potential applications in the different occupational environments particularly for monitoring the personal exposure of industry workers.</div></div>","PeriodicalId":14880,"journal":{"name":"Journal of Aerosol Science","volume":"184 ","pages":"Article 106519"},"PeriodicalIF":3.9000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Aerosol Science","FirstCategoryId":"93","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0021850224001861","RegionNum":3,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Surface mining operations emit particulate matter (PM) with varying sizes and compositions, adversely affecting the health of mine workers and adjoining communities. Measurements for regulatory compliance at present are obtained by bulky instruments, which are costly and provide data averaged over a period of time. Recently, low-cost PM sensors (LCPMS) have been increasingly used in indoor and outdoor environments for monitoring real-time PM concentrations with high spatial and temporal resolution. No comprehensive study has been undertaken to evaluate the performance of LCPMS when exposed to uncontrolled high dust concentrations prevailing in the occupational mining environment. The study aimed to achieve this by deploying three sensors (OPC N3, SPS30, and SDS011) in a highly mechanized surface coal mine. A comparative assessment of these sensors has been conducted by calibrating them against a research-grade reference instrument in uncontrolled indoor, outdoor, and mining environments. The performance of OPC N3 and SPS30 sensors was found to be good, with high linearity (R2 = 0.90 – 0.99) and precision (CV = 2 – 6%). Incorporating the monitored local meteorological conditions and PM proportions improved the performance of the applied calibration models. The decision tree-based regression model performed better (R2 = 0.95 – 99; RMSE = 0.8 – 11.4; MAE = 0.4 – 5.3) compared to the multiple linear model in accurately predicting reference equivalent PM mass concentration measurements. The comprehensive performance evaluation of LCPMS in this study highlights its potential applications in the different occupational environments particularly for monitoring the personal exposure of industry workers.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Aerosol Science
Journal of Aerosol Science 环境科学-工程:化工
CiteScore
8.80
自引率
8.90%
发文量
127
审稿时长
35 days
期刊介绍: Founded in 1970, the Journal of Aerosol Science considers itself the prime vehicle for the publication of original work as well as reviews related to fundamental and applied aerosol research, as well as aerosol instrumentation. Its content is directed at scientists working in engineering disciplines, as well as physics, chemistry, and environmental sciences. The editors welcome submissions of papers describing recent experimental, numerical, and theoretical research related to the following topics: 1. Fundamental Aerosol Science. 2. Applied Aerosol Science. 3. Instrumentation & Measurement Methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信