{"title":"Collapse prevention of pre-stressed electric transmission poles using glass fiber reinforced polymers","authors":"Rattapoohm Parichatprecha , Kittipoom Rodsin , Songsak Suthasupradit , Tahir Mehmood , Adnan Nawaz","doi":"10.1016/j.cscm.2024.e04110","DOIUrl":null,"url":null,"abstract":"<div><div>Natural hazards such as strong winds, typhoons, and earthquakes have caused massive economic losses in the form of damage to residential and life-line structures. Electric transmission infrastructures are life-line structures susceptible to severe damage under lateral loads like wind and earthquakes. This study focused on vulnerability assessment and measures to reduce the expected damage to the prestressed electric transmission poles under lateral loads. The Glass Fiber Reinforced Polymer (GFRP) sheet is selected as a strengthening material because the fiber cost is affordable but still has acceptable high tensile strength. A full-scale 12-meter-long prestressed transmission pole was tested under reversed cyclic lateral loading. Furthermore, another specimen strengthened with the GFRP sheet was tested to quantify the effectiveness of this technique. The experimental results show significant improvement in the lateral response behavior of prestressed poles in terms of lateral drift capacity, ductility, and energy dissipation characteristics. The GFRP-strengthened specimen exhibited a significantly enhanced lateral drift capacity (more than 100 %) compared to the control specimen. The performance of GFRP in preventing the collapse of a full-scale transmission pole is proved experimentally in this study. Finally, a numerical model based on the fiber modeling concept was also implemented in the open-source platform OpenSees to simulate the observed hysteretic behavior for strengthened and unstrengthened prestressed electric transmission poles. The application of this strengthening method is shown to be very practical for collapse prevention of existing PC poles both in terms of performance and budget.</div></div>","PeriodicalId":9641,"journal":{"name":"Case Studies in Construction Materials","volume":"22 ","pages":"Article e04110"},"PeriodicalIF":6.5000,"publicationDate":"2024-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Studies in Construction Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214509524012622","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Natural hazards such as strong winds, typhoons, and earthquakes have caused massive economic losses in the form of damage to residential and life-line structures. Electric transmission infrastructures are life-line structures susceptible to severe damage under lateral loads like wind and earthquakes. This study focused on vulnerability assessment and measures to reduce the expected damage to the prestressed electric transmission poles under lateral loads. The Glass Fiber Reinforced Polymer (GFRP) sheet is selected as a strengthening material because the fiber cost is affordable but still has acceptable high tensile strength. A full-scale 12-meter-long prestressed transmission pole was tested under reversed cyclic lateral loading. Furthermore, another specimen strengthened with the GFRP sheet was tested to quantify the effectiveness of this technique. The experimental results show significant improvement in the lateral response behavior of prestressed poles in terms of lateral drift capacity, ductility, and energy dissipation characteristics. The GFRP-strengthened specimen exhibited a significantly enhanced lateral drift capacity (more than 100 %) compared to the control specimen. The performance of GFRP in preventing the collapse of a full-scale transmission pole is proved experimentally in this study. Finally, a numerical model based on the fiber modeling concept was also implemented in the open-source platform OpenSees to simulate the observed hysteretic behavior for strengthened and unstrengthened prestressed electric transmission poles. The application of this strengthening method is shown to be very practical for collapse prevention of existing PC poles both in terms of performance and budget.
期刊介绍:
Case Studies in Construction Materials provides a forum for the rapid publication of short, structured Case Studies on construction materials. In addition, the journal also publishes related Short Communications, Full length research article and Comprehensive review papers (by invitation).
The journal will provide an essential compendium of case studies for practicing engineers, designers, researchers and other practitioners who are interested in all aspects construction materials. The journal will publish new and novel case studies, but will also provide a forum for the publication of high quality descriptions of classic construction material problems and solutions.