A green validated HPLC-UV Method for determining and quantifying pholcodine, paracetamol, and pseudoephedrine in laboratory-prepared mixtures and their FDC capsule

Mennatallah Hesham Ahmed , Ehab F. Elkady , Sally Tarek Mahmoud , Ekram Hany Mohamed
{"title":"A green validated HPLC-UV Method for determining and quantifying pholcodine, paracetamol, and pseudoephedrine in laboratory-prepared mixtures and their FDC capsule","authors":"Mennatallah Hesham Ahmed ,&nbsp;Ehab F. Elkady ,&nbsp;Sally Tarek Mahmoud ,&nbsp;Ekram Hany Mohamed","doi":"10.1016/j.greeac.2024.100187","DOIUrl":null,"url":null,"abstract":"<div><div>A validated technique has been developed for the sequential determination of pholcodine, paracetamol, and pseudoephedrine. This method allows for their separation either in different ratios within a ternary mixture or in their fixed-dose combination (FDC) using HPLC. The chromatographic conditions involved the utilization of an X-select C<sub>18</sub> column (5µ, 4.6 × 150 mm) and a mobile phase consisting of 0.05 M KH<sub>2</sub>PO<sub>4</sub>: Methanol (75:25, v/v), with orthophosphoric acid added to adjust the pH to 2.6. The separation was conducted at a 1.2 ml/min flow rate, while a UV detector was set at a wavelength of 206 nm to monitor the process. The three drugs were successfully eluted with retention times of 0.8, 1.9, and 3.0 min for pholcodine, paracetamol, and pseudoephedrine respectively providing fast analysis times.</div><div>The method exhibited linearity for pholcodine, paracetamol, and pseudoephedrine over concentration ranges of 12–200 µg/ml, 5–100 µg/ml, and 30–200 µg/ml, respectively. It was accurate, reliable, and precise (RSD &lt; 2 %). This proposed methodology was effectively implemented to quantify the concentration of pholcodine, pseudoephedrine, and paracetamol in freshly prepared mixtures and pharmaceutical dosage forms. Furthermore, the method's environmental impact was assessed using five different tools, demonstrating low hazard levels to the environment, and promoting its environmental friendliness compared to the reported method.</div></div>","PeriodicalId":100594,"journal":{"name":"Green Analytical Chemistry","volume":"12 ","pages":"Article 100187"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Green Analytical Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S277257742400096X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A validated technique has been developed for the sequential determination of pholcodine, paracetamol, and pseudoephedrine. This method allows for their separation either in different ratios within a ternary mixture or in their fixed-dose combination (FDC) using HPLC. The chromatographic conditions involved the utilization of an X-select C18 column (5µ, 4.6 × 150 mm) and a mobile phase consisting of 0.05 M KH2PO4: Methanol (75:25, v/v), with orthophosphoric acid added to adjust the pH to 2.6. The separation was conducted at a 1.2 ml/min flow rate, while a UV detector was set at a wavelength of 206 nm to monitor the process. The three drugs were successfully eluted with retention times of 0.8, 1.9, and 3.0 min for pholcodine, paracetamol, and pseudoephedrine respectively providing fast analysis times.
The method exhibited linearity for pholcodine, paracetamol, and pseudoephedrine over concentration ranges of 12–200 µg/ml, 5–100 µg/ml, and 30–200 µg/ml, respectively. It was accurate, reliable, and precise (RSD < 2 %). This proposed methodology was effectively implemented to quantify the concentration of pholcodine, pseudoephedrine, and paracetamol in freshly prepared mixtures and pharmaceutical dosage forms. Furthermore, the method's environmental impact was assessed using five different tools, demonstrating low hazard levels to the environment, and promoting its environmental friendliness compared to the reported method.
绿色高效液相色谱-紫外分光光度法测定和定量实验室配制混合物及其FDC胶囊中的福可定、扑热息痛和伪麻黄碱
建立了一种有效的测定福可定、扑热息痛和伪麻黄碱的方法。该方法允许它们在三元混合物中以不同比例或在其固定剂量组合(FDC)中使用HPLC分离。色谱条件为:采用X-select C18色谱柱(5µ,4.6 × 150 mm),流动相为0.05 M KH2PO4:甲醇(75:25,v/v),加入正磷酸调节pH至2.6。以1.2 ml/min的流速进行分离,并设置波长为206 nm的紫外检测器监测分离过程。对福可定、对乙酰氨基酚和伪麻黄碱的洗脱时间分别为0.8、1.9和3.0 min,洗脱时间较短。该方法在12 ~ 200µg/ml、5 ~ 100µg/ml和30 ~ 200µg/ml的浓度范围内均呈线性关系。它准确、可靠、精确(RSD <;2%)。该方法被有效地用于定量新配制的混合物和药物剂型中福可定、伪麻黄碱和扑热息痛的浓度。此外,使用五种不同的工具评估了该方法的环境影响,表明对环境的危害程度较低,与报告的方法相比,促进了其环境友好性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.00
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信