{"title":"Swirl impact on the overall cooling characteristics of an effusion -cooled combustor liner with cylindrical and fan-shaped holes","authors":"Xiang Lu ,&nbsp;Yongbin Ji ,&nbsp;Bing Ge ,&nbsp;Shusheng Zang","doi":"10.1016/j.ijheatfluidflow.2024.109688","DOIUrl":null,"url":null,"abstract":"<div><div>The swirl impact on the overall effusion cooling characteristics is investigated. Two typical hole configurations, cylindrical and fan-shaped holes, are studied under different blowing ratios (<em>BR</em>). The overall cooling effectiveness is obtained by IR camera and the flow features are analyzed by simulations. The result shows that the typical cooling characteristic is the existence of low-effectiveness regions at where the swirl impact the wall. The reason for this is that the swirl flows destroy the cooling film and suppress the cooling air, resulting in poor cooling effectiveness. At the plate beginning, the cooling effectiveness is high because the corner recirculation pushes the cooling air upstream to cover the wall. The ending of the plate has the best cooling performance due to the gradually superimposed cooling film. Increasing the <em>BR</em> weakens the influence of the swirl impact and improves the cooling effects, therefore the area average cooling effectiveness of the cylindrical holes increases from 0.334 to 0.688 and the cooling effectiveness unevenness decreases from 0.042 to 0.036. The fan-shaped holes have a maximum of 0.063 higher cooling effectiveness due to better film coverage. However, the fan-shaped holes have a stronger cooling effectiveness unevenness, which is 0.012 higher. And the lowest cooling effectiveness is 0.133 and 0.146 lower than the area average value for the cylindrical and fan-shaped holes, respectively. The reason for this is that the fan-shaped holes have similarly poor film cooling in the swirl impact zone but better film cooling effectiveness in the other regions.</div></div>","PeriodicalId":335,"journal":{"name":"International Journal of Heat and Fluid Flow","volume":"112 ","pages":"Article 109688"},"PeriodicalIF":2.6000,"publicationDate":"2024-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Heat and Fluid Flow","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0142727X24004132","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The swirl impact on the overall effusion cooling characteristics is investigated. Two typical hole configurations, cylindrical and fan-shaped holes, are studied under different blowing ratios (BR). The overall cooling effectiveness is obtained by IR camera and the flow features are analyzed by simulations. The result shows that the typical cooling characteristic is the existence of low-effectiveness regions at where the swirl impact the wall. The reason for this is that the swirl flows destroy the cooling film and suppress the cooling air, resulting in poor cooling effectiveness. At the plate beginning, the cooling effectiveness is high because the corner recirculation pushes the cooling air upstream to cover the wall. The ending of the plate has the best cooling performance due to the gradually superimposed cooling film. Increasing the BR weakens the influence of the swirl impact and improves the cooling effects, therefore the area average cooling effectiveness of the cylindrical holes increases from 0.334 to 0.688 and the cooling effectiveness unevenness decreases from 0.042 to 0.036. The fan-shaped holes have a maximum of 0.063 higher cooling effectiveness due to better film coverage. However, the fan-shaped holes have a stronger cooling effectiveness unevenness, which is 0.012 higher. And the lowest cooling effectiveness is 0.133 and 0.146 lower than the area average value for the cylindrical and fan-shaped holes, respectively. The reason for this is that the fan-shaped holes have similarly poor film cooling in the swirl impact zone but better film cooling effectiveness in the other regions.
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Heat and Fluid Flow
International Journal of Heat and Fluid Flow 工程技术-工程:机械
CiteScore
5.00
自引率
7.70%
发文量
131
审稿时长
33 days
期刊介绍: The International Journal of Heat and Fluid Flow welcomes high-quality original contributions on experimental, computational, and physical aspects of convective heat transfer and fluid dynamics relevant to engineering or the environment, including multiphase and microscale flows. Papers reporting the application of these disciplines to design and development, with emphasis on new technological fields, are also welcomed. Some of these new fields include microscale electronic and mechanical systems; medical and biological systems; and thermal and flow control in both the internal and external environment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信