{"title":"EUS-based shear wave elastography of the spleen for detection of clinically significant portal hypertension","authors":"Jad P. AbiMansour MD , Jerry Yung-Lun Chin MBBS , Eric J. Vargas MD , Jyotroop Kaur MBBS , Barham K. Abu Dayyeh MD, MPH , Ryan J. Law DO , Vishal Garimella MBBS , Michael J. Levy MD , Andrew C. Storm MD , Ross Dierkhising MS , Alina Allen MD , Vinay Chandrasekhara MD","doi":"10.1016/j.igie.2024.09.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and Aims</h3><div>A measurement of spleen stiffness has been demonstrated to improve the detection of clinically significant portal hypertension (CSPH). In this study, we evaluated the performance of EUS-guided shear wave elastography (EUS-SWE) for detecting CSPH.</div></div><div><h3>Methods</h3><div>EUS-SWE measurements of the spleen were compared between patients with and without CSPH. Receiver-operating characteristic curve analysis was performed and quantified by the area under the receiver-operating characteristic curve (AUROC).</div></div><div><h3>Results</h3><div>Of 142 patients with EUS-SWE spleen measurements, 13 (9.2%) had CSPH and 129 (90.8%) did not. Patients with CSPH had a significantly higher mean spleen stiffness (37.6 ± 8.5 kPA vs 29.1 ± 9.9 kPA, <em>P</em> = .003). The AUROC was .74.</div></div><div><h3>Conclusions</h3><div>SWE is a promising technology that can readily be incorporated into standard EUS examination for assessment of portal hypertension.</div></div>","PeriodicalId":100652,"journal":{"name":"iGIE","volume":"3 4","pages":"Pages 507-511"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"iGIE","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2949708624001171","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background and Aims
A measurement of spleen stiffness has been demonstrated to improve the detection of clinically significant portal hypertension (CSPH). In this study, we evaluated the performance of EUS-guided shear wave elastography (EUS-SWE) for detecting CSPH.
Methods
EUS-SWE measurements of the spleen were compared between patients with and without CSPH. Receiver-operating characteristic curve analysis was performed and quantified by the area under the receiver-operating characteristic curve (AUROC).
Results
Of 142 patients with EUS-SWE spleen measurements, 13 (9.2%) had CSPH and 129 (90.8%) did not. Patients with CSPH had a significantly higher mean spleen stiffness (37.6 ± 8.5 kPA vs 29.1 ± 9.9 kPA, P = .003). The AUROC was .74.
Conclusions