Nitrogen-rich covalent organic polymers for efficient solid phase extraction of nonsteroidal anti-inflammatory drugs from water samples

IF 5.2 Q1 CHEMISTRY, ANALYTICAL
Yuqi Cheng , Jia Li , Xiaochen Xiu , Xinghua Teng , Wen Zhang , Lei Ji , Leilei Wang
{"title":"Nitrogen-rich covalent organic polymers for efficient solid phase extraction of nonsteroidal anti-inflammatory drugs from water samples","authors":"Yuqi Cheng ,&nbsp;Jia Li ,&nbsp;Xiaochen Xiu ,&nbsp;Xinghua Teng ,&nbsp;Wen Zhang ,&nbsp;Lei Ji ,&nbsp;Leilei Wang","doi":"10.1016/j.sampre.2025.100148","DOIUrl":null,"url":null,"abstract":"<div><div>Non-steroidal anti-inflammatory drugs (NSAIDs) have received increasing attention owing to their ubiquitous occurrence in environmental water systems and adverse effects. In order to monitor trace levels of NSAIDs from complex water samples, development of facile and efficient sample pretreatment is of great significance. Herein, a nitrogen-rich covalent organic polymer containing phenyl, triazine and amine groups was fabricated via solvent-free copolymerization. Then, utilizing nitrogen-rich covalent organic polymer as adsorbent for solid phase extraction cartridges, the pretreatment method was combined with high-performance liquid chromatography-diode array detection to quantify five representative NSAIDs (ketoprofen, carprofen, flurbiprofen, diclofenac and mefenamic acid) in environmental water samples. Under the optimal extraction conditions (adsorbent amount: 40 mg; NaCl concentration: 0%; pH 6; extraction time: 20min; eluent solvent: 4 mL of formic acid/acetonitrile (5%, v/v)), the proposed method provided low detection limits (0.06–0.2 μg L<sup>-1</sup>), wide linear ranges (0.2–100 μg L<sup>-1</sup>) with correlation coefficients (0.9991–0.9997) and acceptable precision (RSDs, 6.6–8.5% for intra-day, 7.2–9.5% for inter-day). The practical application of the method was confirmed through the successful determination of NSAIDs in tap water, surface water, and sewage. The recoveries in these samples at the four NSAIDs concentration levels ranged from 81.3% to 109.8%, with the RSDs lower than 7.8%.</div></div>","PeriodicalId":100052,"journal":{"name":"Advances in Sample Preparation","volume":"13 ","pages":"Article 100148"},"PeriodicalIF":5.2000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Sample Preparation","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772582025000026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Non-steroidal anti-inflammatory drugs (NSAIDs) have received increasing attention owing to their ubiquitous occurrence in environmental water systems and adverse effects. In order to monitor trace levels of NSAIDs from complex water samples, development of facile and efficient sample pretreatment is of great significance. Herein, a nitrogen-rich covalent organic polymer containing phenyl, triazine and amine groups was fabricated via solvent-free copolymerization. Then, utilizing nitrogen-rich covalent organic polymer as adsorbent for solid phase extraction cartridges, the pretreatment method was combined with high-performance liquid chromatography-diode array detection to quantify five representative NSAIDs (ketoprofen, carprofen, flurbiprofen, diclofenac and mefenamic acid) in environmental water samples. Under the optimal extraction conditions (adsorbent amount: 40 mg; NaCl concentration: 0%; pH 6; extraction time: 20min; eluent solvent: 4 mL of formic acid/acetonitrile (5%, v/v)), the proposed method provided low detection limits (0.06–0.2 μg L-1), wide linear ranges (0.2–100 μg L-1) with correlation coefficients (0.9991–0.9997) and acceptable precision (RSDs, 6.6–8.5% for intra-day, 7.2–9.5% for inter-day). The practical application of the method was confirmed through the successful determination of NSAIDs in tap water, surface water, and sewage. The recoveries in these samples at the four NSAIDs concentration levels ranged from 81.3% to 109.8%, with the RSDs lower than 7.8%.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信