Optimal Solar-Biomass-Diesel-Generator Hybrid Energy for Water Pumping System Considering Demand Response

IF 1.8 Q3 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS
Olumuyiwa Taiwo Amusan, Nnamdi Ikechi Nwulu, Saheed Lekan Gbadamosi
{"title":"Optimal Solar-Biomass-Diesel-Generator Hybrid Energy for Water Pumping System Considering Demand Response","authors":"Olumuyiwa Taiwo Amusan,&nbsp;Nnamdi Ikechi Nwulu,&nbsp;Saheed Lekan Gbadamosi","doi":"10.1002/eng2.13055","DOIUrl":null,"url":null,"abstract":"<p>The water pumping system is a vital daily operation for a sustainable society. The demand for this essential commodity is progressively growing around the world. Incorporating renewable energy sources (RES) into its operation mitigates adverse environmental effects stemming from greenhouse gas (GHG) emissions and reduces associated costs linked to fossil fuel energy sources. Hence, the optimal sizing of a hybrid mix of RES and non-RES energy sources to power water pumping is essential. This study employs a generalized reduced gradient (GRG) optimization method to ascertain the most effective energy mix for water pumping system (WPS) application by integrating time of use demand response. This is achieved through four scenarios: Scenario 1 (S1) utilizes grid power and Diesel generator (DG) energy sources, Scenario 2 (S2) incorporates grid power, DG, and solar PV, Scenario 3 (S3) integrates grid power, DG, solar PV, and biomass energy sources, while Scenario 4 (S4) incorporates Time of Use (TOU) with the three aforementioned energy sources. The key findings reveal an ideal solution comprising of a mix of renewable PV and biomass along with non-renewable grid energy source embedded with Time of Use demand response (S4) with optimal energy capacities of 4007 kW of PV, 4228 kW of grid, 234 kW of biomass, and 1085 of DG owing to the least cost energy and cost of water pumped of 0.75$/kW and 1.74$/kL, respectively, most volume of water pumped of 270.50 kL. These findings prove that the integration TOU demand response program with a hybrid mix of grid-biomass-DG-solar PV is best suited for water pumping applications as it gives a cost-competitive value.</p>","PeriodicalId":72922,"journal":{"name":"Engineering reports : open access","volume":"7 1","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/eng2.13055","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering reports : open access","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/eng2.13055","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

Abstract

The water pumping system is a vital daily operation for a sustainable society. The demand for this essential commodity is progressively growing around the world. Incorporating renewable energy sources (RES) into its operation mitigates adverse environmental effects stemming from greenhouse gas (GHG) emissions and reduces associated costs linked to fossil fuel energy sources. Hence, the optimal sizing of a hybrid mix of RES and non-RES energy sources to power water pumping is essential. This study employs a generalized reduced gradient (GRG) optimization method to ascertain the most effective energy mix for water pumping system (WPS) application by integrating time of use demand response. This is achieved through four scenarios: Scenario 1 (S1) utilizes grid power and Diesel generator (DG) energy sources, Scenario 2 (S2) incorporates grid power, DG, and solar PV, Scenario 3 (S3) integrates grid power, DG, solar PV, and biomass energy sources, while Scenario 4 (S4) incorporates Time of Use (TOU) with the three aforementioned energy sources. The key findings reveal an ideal solution comprising of a mix of renewable PV and biomass along with non-renewable grid energy source embedded with Time of Use demand response (S4) with optimal energy capacities of 4007 kW of PV, 4228 kW of grid, 234 kW of biomass, and 1085 of DG owing to the least cost energy and cost of water pumped of 0.75$/kW and 1.74$/kL, respectively, most volume of water pumped of 270.50 kL. These findings prove that the integration TOU demand response program with a hybrid mix of grid-biomass-DG-solar PV is best suited for water pumping applications as it gives a cost-competitive value.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.10
自引率
0.00%
发文量
0
审稿时长
19 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信