Development and Validation of a Gas Chromatography-Mass Spectrometry Method for the Determination of Fentanyl and Butyryl Fentanyl in Oral Fluid

IF 3 Q2 CHEMISTRY, ANALYTICAL
Nicola Camedda, Sara Dagoli, Luca Anzillotti, Rossana Cecchi
{"title":"Development and Validation of a Gas Chromatography-Mass Spectrometry Method for the Determination of Fentanyl and Butyryl Fentanyl in Oral Fluid","authors":"Nicola Camedda,&nbsp;Sara Dagoli,&nbsp;Luca Anzillotti,&nbsp;Rossana Cecchi","doi":"10.1002/ansa.202400038","DOIUrl":null,"url":null,"abstract":"<p>Synthetic opioids are lab-synthesized substances that target the brain's opioid receptors, offering analgesic and sedative effects. Amongst them, fentanyl is one of the most widely used to intervene in chronic pain in moderate to severe cancer situations. Butyryl fentanyl (BF) is a novel synthetic opioid whose use is growing. Its potency is seven times that of morphine and, unlike fentanyl, BF can only be obtained through illegal sources. Fentanyl and its analogues are related to harmful intoxications and an increase in opioid-related mortality in many countries, such as in the United States and Europe in recent years. This work developed and validated an effective and sensitive method based on solid-phase extraction followed by gas chromatography-mass spectrometry (GC-MS) for the determination of fentanyl and BF in oral fluid samples. To the best of our knowledge, it is the first successful attempt to quantify these analytes using GC-MS with a limit of quantification (LOQ) of 1 ng/mL in OF. Intra-day and inter-day percentage coefficient of variation were found within 1%–3% and 1%–14%, respectively, while accuracy ranged from 92% to 102% at four concentration levels (lower LOQ [LLOQ], 3, 20, 40 ng/mL) in accordance with the established criteria. The absolute recovery values were in the range of 80.0%–100.0%. The method was linear for all analytes, with quadratic regression of calibration curves always higher than 0.99. The validated method demonstrated its great potential to detect and quantify fentanyl and its analogue in OF and it can be useful not only in forensic investigations of addiction histories but also in epidemiological studies on the spread of fentanyl and BF among workers and/or drivers.</p>","PeriodicalId":93411,"journal":{"name":"Analytical science advances","volume":"6 1","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/ansa.202400038","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical science advances","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ansa.202400038","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Synthetic opioids are lab-synthesized substances that target the brain's opioid receptors, offering analgesic and sedative effects. Amongst them, fentanyl is one of the most widely used to intervene in chronic pain in moderate to severe cancer situations. Butyryl fentanyl (BF) is a novel synthetic opioid whose use is growing. Its potency is seven times that of morphine and, unlike fentanyl, BF can only be obtained through illegal sources. Fentanyl and its analogues are related to harmful intoxications and an increase in opioid-related mortality in many countries, such as in the United States and Europe in recent years. This work developed and validated an effective and sensitive method based on solid-phase extraction followed by gas chromatography-mass spectrometry (GC-MS) for the determination of fentanyl and BF in oral fluid samples. To the best of our knowledge, it is the first successful attempt to quantify these analytes using GC-MS with a limit of quantification (LOQ) of 1 ng/mL in OF. Intra-day and inter-day percentage coefficient of variation were found within 1%–3% and 1%–14%, respectively, while accuracy ranged from 92% to 102% at four concentration levels (lower LOQ [LLOQ], 3, 20, 40 ng/mL) in accordance with the established criteria. The absolute recovery values were in the range of 80.0%–100.0%. The method was linear for all analytes, with quadratic regression of calibration curves always higher than 0.99. The validated method demonstrated its great potential to detect and quantify fentanyl and its analogue in OF and it can be useful not only in forensic investigations of addiction histories but also in epidemiological studies on the spread of fentanyl and BF among workers and/or drivers.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.60
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信