Influence of Opening Size and Position on the Performance of Forced-Air Precooling of Apples

IF 2.7 3区 农林科学 Q3 ENGINEERING, CHEMICAL
Xiaozhuan Chen, Yunpeng Wang, Wei Sheng, Haikun Zheng, Maierzukejiang Bayizi, Shishun Pan, Sikai Liu, Dong Li
{"title":"Influence of Opening Size and Position on the Performance of Forced-Air Precooling of Apples","authors":"Xiaozhuan Chen,&nbsp;Yunpeng Wang,&nbsp;Wei Sheng,&nbsp;Haikun Zheng,&nbsp;Maierzukejiang Bayizi,&nbsp;Shishun Pan,&nbsp;Sikai Liu,&nbsp;Dong Li","doi":"10.1111/jfpe.70024","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>In this article, to investigate the comprehensive influence of the opening size and location of the packing box on precooling performance, a simulation model of precooling with 20 opening parameters is established based on computational fluid dynamics. There are six openings on one side of the box, 12 in total, with 5 opening positions (Cases 1–5) and 4 opening sizes, each with an opening size and corresponding total opening area of 15 mm (2120 mm<sup>2</sup>), 30 mm (8482 mm<sup>2</sup>), 45 mm (19,085 mm<sup>2</sup>), and 60 mm (33,929 mm<sup>2</sup>). The results show that when the diameter of the opening is 15–60 mm, increasing the opening increases the precooling time, and Case 4, which moves the position of the openings on both sides to the left and right, reduces the precooling time. Increasing the opening does not necessarily improve precooling uniformity at different opening positions. Case 5, with the position of the two side openings moved toward the center, had the worst precooling uniformity for each opening size. The larger the opening, the lower the precooling energy consumption for a given opening position. This is because the reduction in power at increased opening is much greater than the increase in precooling time. When the opening size is certain, the reasonable opening position can reduce the precooling energy consumption. Case 4, 30 mm is more balanced overall. Therefore, the opening parameter has a large impact on the precooling performance, and it is necessary to select the opening parameter reasonably for different requirements.</p>\n </div>","PeriodicalId":15932,"journal":{"name":"Journal of Food Process Engineering","volume":"48 1","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2025-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Food Process Engineering","FirstCategoryId":"97","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jfpe.70024","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In this article, to investigate the comprehensive influence of the opening size and location of the packing box on precooling performance, a simulation model of precooling with 20 opening parameters is established based on computational fluid dynamics. There are six openings on one side of the box, 12 in total, with 5 opening positions (Cases 1–5) and 4 opening sizes, each with an opening size and corresponding total opening area of 15 mm (2120 mm2), 30 mm (8482 mm2), 45 mm (19,085 mm2), and 60 mm (33,929 mm2). The results show that when the diameter of the opening is 15–60 mm, increasing the opening increases the precooling time, and Case 4, which moves the position of the openings on both sides to the left and right, reduces the precooling time. Increasing the opening does not necessarily improve precooling uniformity at different opening positions. Case 5, with the position of the two side openings moved toward the center, had the worst precooling uniformity for each opening size. The larger the opening, the lower the precooling energy consumption for a given opening position. This is because the reduction in power at increased opening is much greater than the increase in precooling time. When the opening size is certain, the reasonable opening position can reduce the precooling energy consumption. Case 4, 30 mm is more balanced overall. Therefore, the opening parameter has a large impact on the precooling performance, and it is necessary to select the opening parameter reasonably for different requirements.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Food Process Engineering
Journal of Food Process Engineering 工程技术-工程:化工
CiteScore
5.70
自引率
10.00%
发文量
259
审稿时长
2 months
期刊介绍: This international research journal focuses on the engineering aspects of post-production handling, storage, processing, packaging, and distribution of food. Read by researchers, food and chemical engineers, and industry experts, this is the only international journal specifically devoted to the engineering aspects of food processing. Co-Editors M. Elena Castell-Perez and Rosana Moreira, both of Texas A&M University, welcome papers covering the best original research on applications of engineering principles and concepts to food and food processes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信