Enhancement of Signal-to-Background Ratio in Molecular Vibrational Signal Extraction by Stimulated Emission Depletion Mechanism

IF 3.7 Q2 MATERIALS SCIENCE, MULTIDISCIPLINARY
Ge Wang, Lizhen Chen, Qiuqiang Zhan, Guangyou Fang, Yisen Wang
{"title":"Enhancement of Signal-to-Background Ratio in Molecular Vibrational Signal Extraction by Stimulated Emission Depletion Mechanism","authors":"Ge Wang,&nbsp;Lizhen Chen,&nbsp;Qiuqiang Zhan,&nbsp;Guangyou Fang,&nbsp;Yisen Wang","doi":"10.1002/adpr.202400078","DOIUrl":null,"url":null,"abstract":"<p>Herein, a novel approach is presented to mitigate the fluorescence interference during the detection of vibrational signal via the stimulated emission depletion (STED). STED is the mechanism commonly employed in optical imaging; however, its application should not be confined solely to this field. To explore additional possibilities, a novel application of STED in vibrational spectroscopy detection is introduced. Vibrational spectroscopy is a widely used technique for the material detection and identification, but its sensitivity is influenced by impurity signals, especially the fluorescence. The proposed method is capable of suppressing fluorescence without influencing vibrational signal. At the low concentration of fluorescent impurities, the signal-to-background ratio of vibrational spectroscopy is 2.6 times as high as that without this method. The introduction of depletion light can enhance the detection of vibrational signals, resulting in more optimal signal detection. A promising new application of STED other than super-resolution imaging is investigated.</p>","PeriodicalId":7263,"journal":{"name":"Advanced Photonics Research","volume":"6 1","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2024-08-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/adpr.202400078","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Photonics Research","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/adpr.202400078","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Herein, a novel approach is presented to mitigate the fluorescence interference during the detection of vibrational signal via the stimulated emission depletion (STED). STED is the mechanism commonly employed in optical imaging; however, its application should not be confined solely to this field. To explore additional possibilities, a novel application of STED in vibrational spectroscopy detection is introduced. Vibrational spectroscopy is a widely used technique for the material detection and identification, but its sensitivity is influenced by impurity signals, especially the fluorescence. The proposed method is capable of suppressing fluorescence without influencing vibrational signal. At the low concentration of fluorescent impurities, the signal-to-background ratio of vibrational spectroscopy is 2.6 times as high as that without this method. The introduction of depletion light can enhance the detection of vibrational signals, resulting in more optimal signal detection. A promising new application of STED other than super-resolution imaging is investigated.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
2.70%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信