Time-Series Load Online Prediction of Wind Turbine Based on Adaptive Multisource Operational Data Fusion

IF 1.9 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
Ruojin Wang, Xiaodong Wang, Deyi Fu, Bin Yang, Yingming Liu
{"title":"Time-Series Load Online Prediction of Wind Turbine Based on Adaptive Multisource Operational Data Fusion","authors":"Ruojin Wang,&nbsp;Xiaodong Wang,&nbsp;Deyi Fu,&nbsp;Bin Yang,&nbsp;Yingming Liu","doi":"10.1155/etep/5972382","DOIUrl":null,"url":null,"abstract":"<div>\n <p>Aiming at the problem that the stochastic change of wind turbine generator (WTG) working conditions and the complex nonlinear relationship between load and operation data make it difficult to predict the short-term load online, this paper proposes an adaptive multi-information source data fusion online prediction method for WTG load. Random forest (RF) and WaveNet time series (WTS) are established as subinformation source models, and the influence of input features and historical data on load prediction is considered from horizontal and vertical dimensions. In order to reduce the influence of original data completeness on load prediction, the deviation degree of load prediction of RF and WTS is analyzed. The deviation degree of the subinformation source model is used as the basis for judgment, and it is fused into a multi-information source load model with adaptive deviation degree analysis to predict the loads on the blades, tower top, and tower bottom of the wind turbine. According to the 15 MW semisubmersible offshore WTG load prediction example, the prediction error of this method is about 4% under normal data conditions and 6% under abnormal data conditions, and the calculation time of 200 sets of test data is 0.053 s, which meets the needs of pitch control and has the potential to be applied in the optimization of pitch control strategy.</p>\n </div>","PeriodicalId":51293,"journal":{"name":"International Transactions on Electrical Energy Systems","volume":"2025 1","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2025-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1155/etep/5972382","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Transactions on Electrical Energy Systems","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/etep/5972382","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Aiming at the problem that the stochastic change of wind turbine generator (WTG) working conditions and the complex nonlinear relationship between load and operation data make it difficult to predict the short-term load online, this paper proposes an adaptive multi-information source data fusion online prediction method for WTG load. Random forest (RF) and WaveNet time series (WTS) are established as subinformation source models, and the influence of input features and historical data on load prediction is considered from horizontal and vertical dimensions. In order to reduce the influence of original data completeness on load prediction, the deviation degree of load prediction of RF and WTS is analyzed. The deviation degree of the subinformation source model is used as the basis for judgment, and it is fused into a multi-information source load model with adaptive deviation degree analysis to predict the loads on the blades, tower top, and tower bottom of the wind turbine. According to the 15 MW semisubmersible offshore WTG load prediction example, the prediction error of this method is about 4% under normal data conditions and 6% under abnormal data conditions, and the calculation time of 200 sets of test data is 0.053 s, which meets the needs of pitch control and has the potential to be applied in the optimization of pitch control strategy.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
International Transactions on Electrical Energy Systems
International Transactions on Electrical Energy Systems ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
6.70
自引率
8.70%
发文量
342
期刊介绍: International Transactions on Electrical Energy Systems publishes original research results on key advances in the generation, transmission, and distribution of electrical energy systems. Of particular interest are submissions concerning the modeling, analysis, optimization and control of advanced electric power systems. Manuscripts on topics of economics, finance, policies, insulation materials, low-voltage power electronics, plasmas, and magnetics will generally not be considered for review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信