Implementation of a FPGA-Based Time-to-Digital Converter Utilizing Opposite-Transition Propagation and Virtual Bin Method

IF 4.6 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Daehee Lee;Sun Il Kwon
{"title":"Implementation of a FPGA-Based Time-to-Digital Converter Utilizing Opposite-Transition Propagation and Virtual Bin Method","authors":"Daehee Lee;Sun Il Kwon","doi":"10.1109/TRPMS.2024.3457618","DOIUrl":null,"url":null,"abstract":"We propose an field-programmable gate array (FPGA)-based time-to-digital converter (TDC) that utilizes a virtual bin (VB) approach with opposite-transition (OT) inputs on two tapped-delay lines (TDLs) to obtain less-correlated time bins. The VBs from the proposed OT TDC were obtained by comparing and segmenting the less-correlated bins collected from the two TDLs. The OT TDC was implemented on a 7-series FPGA (Xilinx) to verify performance. A conventional monotonic-transition (MT) TDC, which used identical transition inputs (0-to-1 or 1-to-0 transition) for the two TDLs, was also implemented as a control group. The results were compared with those from the MT TDC and other studies. The proposed method effectively improves time resolution and integral linearity while keeping resource usage low by exploiting these characteristics. The average bin size and RMS value were 5.5 and 4.2 ps, respectively. Moreover, the proposed method exhibits stable performance under temperature variations and implementation location changes. The VB OT TDC, which applies the VB method to the OT TDC, successfully measures detection time differences of two signals from two Cerenkov radiator integrated microchannel plate photomultiplier tubes (CRI-MCP-PMTs) with a high-timing precision of sub-100 ps. The VB OT TDC can be used for next-generation applications that require fast-timing measurements.","PeriodicalId":46807,"journal":{"name":"IEEE Transactions on Radiation and Plasma Medical Sciences","volume":"9 2","pages":"148-156"},"PeriodicalIF":4.6000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Radiation and Plasma Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10673987/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

We propose an field-programmable gate array (FPGA)-based time-to-digital converter (TDC) that utilizes a virtual bin (VB) approach with opposite-transition (OT) inputs on two tapped-delay lines (TDLs) to obtain less-correlated time bins. The VBs from the proposed OT TDC were obtained by comparing and segmenting the less-correlated bins collected from the two TDLs. The OT TDC was implemented on a 7-series FPGA (Xilinx) to verify performance. A conventional monotonic-transition (MT) TDC, which used identical transition inputs (0-to-1 or 1-to-0 transition) for the two TDLs, was also implemented as a control group. The results were compared with those from the MT TDC and other studies. The proposed method effectively improves time resolution and integral linearity while keeping resource usage low by exploiting these characteristics. The average bin size and RMS value were 5.5 and 4.2 ps, respectively. Moreover, the proposed method exhibits stable performance under temperature variations and implementation location changes. The VB OT TDC, which applies the VB method to the OT TDC, successfully measures detection time differences of two signals from two Cerenkov radiator integrated microchannel plate photomultiplier tubes (CRI-MCP-PMTs) with a high-timing precision of sub-100 ps. The VB OT TDC can be used for next-generation applications that require fast-timing measurements.
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Radiation and Plasma Medical Sciences
IEEE Transactions on Radiation and Plasma Medical Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
8.00
自引率
18.20%
发文量
109
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信