Imaging measurements of percutaneous posterior quadcortical screw fixation of vertebral bodies

IF 1.7 4区 综合性期刊 Q2 MULTIDISCIPLINARY SCIENCES
Zheng Xie, Cheng-Shi Liu, Han Yang, Jian Yang, Jian-Ping Kang
{"title":"Imaging measurements of percutaneous posterior quadcortical screw fixation of vertebral bodies","authors":"Zheng Xie,&nbsp;Cheng-Shi Liu,&nbsp;Han Yang,&nbsp;Jian Yang,&nbsp;Jian-Ping Kang","doi":"10.1016/j.jrras.2024.101257","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>To investigate the feasibility of percutaneous posterior quadcortical screw fixation of adjacent vertebrae for the treatment of lumbar degenerative diseases by imaging measurements.</div></div><div><h3>Methods</h3><div>A total of 192 patients with lumbar degenerative diseases who were treated in our hospital from October 2020 to October 2021 were included in this study. They have received percutaneous posterior quadcortical screw fixation of adjacent vertebrae. The insertion point was corrected by inserting quadcortical screws into cadaver specimens. The measured parameters in computed tomography three-dimensional (CT 3D) images main included safety range of screw track angle A, the minimum value of screw track Bmin, and the maximum value of screw track Bmax.</div></div><div><h3>Results</h3><div>The insertion point was 2 mm below the vertex of the herringbone ridge (the junction of the lateral edge of the lamina, the transverse process, and the base of the superior articular process). Screw track safety range angle A was 18.3°–19.7°. Average value range of minimum Bmin of screw trajectory was 4.99–5.39 cm. Maximum value of screw trajectory Bmax was 6.10–6.46 cm. Average length of screw track Bave was 5.55–5.93 cm.</div></div><div><h3>Conclusion</h3><div>Percutaneous posterior quadcortical screw fixation of adjacent vertebrae is feasible for the treatment of lumbar degenerative diseases.</div></div>","PeriodicalId":16920,"journal":{"name":"Journal of Radiation Research and Applied Sciences","volume":"18 1","pages":"Article 101257"},"PeriodicalIF":1.7000,"publicationDate":"2025-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiation Research and Applied Sciences","FirstCategoryId":"103","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1687850724004412","RegionNum":4,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Background

To investigate the feasibility of percutaneous posterior quadcortical screw fixation of adjacent vertebrae for the treatment of lumbar degenerative diseases by imaging measurements.

Methods

A total of 192 patients with lumbar degenerative diseases who were treated in our hospital from October 2020 to October 2021 were included in this study. They have received percutaneous posterior quadcortical screw fixation of adjacent vertebrae. The insertion point was corrected by inserting quadcortical screws into cadaver specimens. The measured parameters in computed tomography three-dimensional (CT 3D) images main included safety range of screw track angle A, the minimum value of screw track Bmin, and the maximum value of screw track Bmax.

Results

The insertion point was 2 mm below the vertex of the herringbone ridge (the junction of the lateral edge of the lamina, the transverse process, and the base of the superior articular process). Screw track safety range angle A was 18.3°–19.7°. Average value range of minimum Bmin of screw trajectory was 4.99–5.39 cm. Maximum value of screw trajectory Bmax was 6.10–6.46 cm. Average length of screw track Bave was 5.55–5.93 cm.

Conclusion

Percutaneous posterior quadcortical screw fixation of adjacent vertebrae is feasible for the treatment of lumbar degenerative diseases.
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
5.90%
发文量
130
审稿时长
16 weeks
期刊介绍: Journal of Radiation Research and Applied Sciences provides a high quality medium for the publication of substantial, original and scientific and technological papers on the development and applications of nuclear, radiation and isotopes in biology, medicine, drugs, biochemistry, microbiology, agriculture, entomology, food technology, chemistry, physics, solid states, engineering, environmental and applied sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信