Precise determination of electrolyte cations in an extracorporeally circulating dialysate with laser-induced breakdown spectroscopy

IF 3.2 2区 化学 Q1 SPECTROSCOPY
Beiyi Zhang , Qi Zhang , Zengqi Yue , Chen Sun , Feng Ding , Jin Yu
{"title":"Precise determination of electrolyte cations in an extracorporeally circulating dialysate with laser-induced breakdown spectroscopy","authors":"Beiyi Zhang ,&nbsp;Qi Zhang ,&nbsp;Zengqi Yue ,&nbsp;Chen Sun ,&nbsp;Feng Ding ,&nbsp;Jin Yu","doi":"10.1016/j.sab.2024.107107","DOIUrl":null,"url":null,"abstract":"<div><div>Hemodialysis as the primary renal replacement therapy for patients afflicted by end-stage renal disease, necessitates monitoring of electrolyte cations in the dialysate to ensure the safety and efficacy of the treatment. Concerned elements include calcium, potassium, and sodium. Currently, prevailing detection methods fall short in providing <em>in situ</em> and real-time detection capabilities, highlighting the need of innovation. Elemental analysis of bulk liquids with laser-induced breakdown spectroscopy (LIBS) presents an interesting potential for dialysate monitoring. Methodological research should further aim to achieve simultaneous multi-element determinations in dialysates with high accuracy and precision, using an arrangement compatible with a flowing dialysate and ready for deployment in a clinical environment. In this work, we developed an experimental arrangement tailored for dialysate analysis, integrating an optimized LIBS setup into a circulating dialysate system, which simulated the clinical operation. Such an arrangement allowed generating a stable and hot plasma within a flowing dialysate. The emission lines from calcium, potassium, and sodium were subsequently captured by a detection system optimized for a simultaneous detection of the three elements with concentrations corresponding to those of a real dialysate. Due to self-absorption of the lines, notably self-reversal of the sodium D-lines, univariate regression, usually efficient for processing LIBS spectra of electrolyte cations in a liquid, was revealed insufficient to provide an analytical performance satisfying the requirements of the clinical practice. Data processing based on multivariate regression was thus developed in this work to substantially improve the model prediction performances. More specifically, back-propagation neural networks (BPNN) coupled with feature selection demonstrated the effectiveness to harness the complexity of the spectrum heavily deformed by self-absorption and self-reversal of the characteristic lines. The resulted models exhibit a limit of detection (LOD) of 0.302, 0.571, and 4.25 mmol/L, respectively for Ca, K, and Na. The prediction performances of the trained models were assessed using independent test samples, yielding root mean square errors of prediction (RMSEP) of 0.106, 0.137, and 0.646 mmol/L for Ca, K, and Na, respectively. Such performances satisfy the clinical requirements for monitoring of electrolyte cations in a dialysate.</div></div>","PeriodicalId":21890,"journal":{"name":"Spectrochimica Acta Part B: Atomic Spectroscopy","volume":"224 ","pages":"Article 107107"},"PeriodicalIF":3.2000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spectrochimica Acta Part B: Atomic Spectroscopy","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0584854724002520","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 0

Abstract

Hemodialysis as the primary renal replacement therapy for patients afflicted by end-stage renal disease, necessitates monitoring of electrolyte cations in the dialysate to ensure the safety and efficacy of the treatment. Concerned elements include calcium, potassium, and sodium. Currently, prevailing detection methods fall short in providing in situ and real-time detection capabilities, highlighting the need of innovation. Elemental analysis of bulk liquids with laser-induced breakdown spectroscopy (LIBS) presents an interesting potential for dialysate monitoring. Methodological research should further aim to achieve simultaneous multi-element determinations in dialysates with high accuracy and precision, using an arrangement compatible with a flowing dialysate and ready for deployment in a clinical environment. In this work, we developed an experimental arrangement tailored for dialysate analysis, integrating an optimized LIBS setup into a circulating dialysate system, which simulated the clinical operation. Such an arrangement allowed generating a stable and hot plasma within a flowing dialysate. The emission lines from calcium, potassium, and sodium were subsequently captured by a detection system optimized for a simultaneous detection of the three elements with concentrations corresponding to those of a real dialysate. Due to self-absorption of the lines, notably self-reversal of the sodium D-lines, univariate regression, usually efficient for processing LIBS spectra of electrolyte cations in a liquid, was revealed insufficient to provide an analytical performance satisfying the requirements of the clinical practice. Data processing based on multivariate regression was thus developed in this work to substantially improve the model prediction performances. More specifically, back-propagation neural networks (BPNN) coupled with feature selection demonstrated the effectiveness to harness the complexity of the spectrum heavily deformed by self-absorption and self-reversal of the characteristic lines. The resulted models exhibit a limit of detection (LOD) of 0.302, 0.571, and 4.25 mmol/L, respectively for Ca, K, and Na. The prediction performances of the trained models were assessed using independent test samples, yielding root mean square errors of prediction (RMSEP) of 0.106, 0.137, and 0.646 mmol/L for Ca, K, and Na, respectively. Such performances satisfy the clinical requirements for monitoring of electrolyte cations in a dialysate.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.10
自引率
12.10%
发文量
173
审稿时长
81 days
期刊介绍: Spectrochimica Acta Part B: Atomic Spectroscopy, is intended for the rapid publication of both original work and reviews in the following fields: Atomic Emission (AES), Atomic Absorption (AAS) and Atomic Fluorescence (AFS) spectroscopy; Mass Spectrometry (MS) for inorganic analysis covering Spark Source (SS-MS), Inductively Coupled Plasma (ICP-MS), Glow Discharge (GD-MS), and Secondary Ion Mass Spectrometry (SIMS). Laser induced atomic spectroscopy for inorganic analysis, including non-linear optical laser spectroscopy, covering Laser Enhanced Ionization (LEI), Laser Induced Fluorescence (LIF), Resonance Ionization Spectroscopy (RIS) and Resonance Ionization Mass Spectrometry (RIMS); Laser Induced Breakdown Spectroscopy (LIBS); Cavity Ringdown Spectroscopy (CRDS), Laser Ablation Inductively Coupled Plasma Atomic Emission Spectroscopy (LA-ICP-AES) and Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS). X-ray spectrometry, X-ray Optics and Microanalysis, including X-ray fluorescence spectrometry (XRF) and related techniques, in particular Total-reflection X-ray Fluorescence Spectrometry (TXRF), and Synchrotron Radiation-excited Total reflection XRF (SR-TXRF). Manuscripts dealing with (i) fundamentals, (ii) methodology development, (iii)instrumentation, and (iv) applications, can be submitted for publication.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信