Volumetric Passive Acoustic Mapping and Cavitation Detection of Nanobubbles under Low-Frequency Insonation

IF 5.7 Q2 CHEMISTRY, PHYSICAL
Hila Shinar,  and , Tali Ilovitsh*, 
{"title":"Volumetric Passive Acoustic Mapping and Cavitation Detection of Nanobubbles under Low-Frequency Insonation","authors":"Hila Shinar,&nbsp; and ,&nbsp;Tali Ilovitsh*,&nbsp;","doi":"10.1021/acsmaterialsau.4c0006410.1021/acsmaterialsau.4c00064","DOIUrl":null,"url":null,"abstract":"<p >Gas bubbles, commonly used in medical ultrasound (US), witness advancements with nanobubbles (NB), providing improved capabilities over microbubbles (MB). NBs offer enhanced penetration into capillaries and the ability to extravasate into tumors following systemic injection, alongside prolonged circulation and persistent acoustic contrast. Low-frequency insonation (&lt;1 MHz) with NBs holds great potential in inducing significant bioeffects, making the monitoring of their acoustic response critical to achieving therapeutic goals. We introduce a US-guided focused US system comprising a one-dimensional (1D) motorized rotating imaging transducer positioned within a low-frequency therapeutic transducer (center frequencies of 105 and 200 kHz), facilitating precise monitoring of NB cavitation activity in three-dimensional (3D) and comparison with MBs. Passive cavitation detection (PCD) revealed frequency-dependent responses, with NBs exhibiting significantly higher stable and inertial cavitation doses compared to MBs of the same gas volume when excited at a center frequency of 105 kHz and peak negative pressures ranging from 100 to 350 kPa. At 200 kHz, MBs showed higher cavitation doses than NBs. PCD showed that 105 kHz enhanced both NBs’ and MBs’ oscillations compared to 200 kHz. The system was further used for 3D passive acoustic mapping (PAM) to provide spatial resolution alongside PCD monitoring. Two-dimensional PAM was captured for each rotation angle and used to generate a complete 3D PAM reconstruction. Experimental results obtained from a tube phantom demonstrated consistent contrast PAM full-width half-maximum (FWHM) as a function of rotation angle, with similar FWHM between MBs and NBs. Frequency-selective PAM maps distinguished between stable and inertial cavitation via the harmonic, ultraharmonic and broadband content, offering insights into cavitation dynamics. These findings highlight NBs’ superior performance at lower frequencies. The developed 3D-PAM technique with a 1D transducer presents a promising technology for real-time, noninvasive monitoring of cavitation-based US therapies.</p>","PeriodicalId":29798,"journal":{"name":"ACS Materials Au","volume":"5 1","pages":"159–169 159–169"},"PeriodicalIF":5.7000,"publicationDate":"2024-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.acs.org/doi/epdf/10.1021/acsmaterialsau.4c00064","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Materials Au","FirstCategoryId":"1085","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acsmaterialsau.4c00064","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Gas bubbles, commonly used in medical ultrasound (US), witness advancements with nanobubbles (NB), providing improved capabilities over microbubbles (MB). NBs offer enhanced penetration into capillaries and the ability to extravasate into tumors following systemic injection, alongside prolonged circulation and persistent acoustic contrast. Low-frequency insonation (<1 MHz) with NBs holds great potential in inducing significant bioeffects, making the monitoring of their acoustic response critical to achieving therapeutic goals. We introduce a US-guided focused US system comprising a one-dimensional (1D) motorized rotating imaging transducer positioned within a low-frequency therapeutic transducer (center frequencies of 105 and 200 kHz), facilitating precise monitoring of NB cavitation activity in three-dimensional (3D) and comparison with MBs. Passive cavitation detection (PCD) revealed frequency-dependent responses, with NBs exhibiting significantly higher stable and inertial cavitation doses compared to MBs of the same gas volume when excited at a center frequency of 105 kHz and peak negative pressures ranging from 100 to 350 kPa. At 200 kHz, MBs showed higher cavitation doses than NBs. PCD showed that 105 kHz enhanced both NBs’ and MBs’ oscillations compared to 200 kHz. The system was further used for 3D passive acoustic mapping (PAM) to provide spatial resolution alongside PCD monitoring. Two-dimensional PAM was captured for each rotation angle and used to generate a complete 3D PAM reconstruction. Experimental results obtained from a tube phantom demonstrated consistent contrast PAM full-width half-maximum (FWHM) as a function of rotation angle, with similar FWHM between MBs and NBs. Frequency-selective PAM maps distinguished between stable and inertial cavitation via the harmonic, ultraharmonic and broadband content, offering insights into cavitation dynamics. These findings highlight NBs’ superior performance at lower frequencies. The developed 3D-PAM technique with a 1D transducer presents a promising technology for real-time, noninvasive monitoring of cavitation-based US therapies.

求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Materials Au
ACS Materials Au 材料科学-
CiteScore
5.00
自引率
0.00%
发文量
0
期刊介绍: ACS Materials Au is an open access journal publishing letters articles reviews and perspectives describing high-quality research at the forefront of fundamental and applied research and at the interface between materials and other disciplines such as chemistry engineering and biology. Papers that showcase multidisciplinary and innovative materials research addressing global challenges are especially welcome. Areas of interest include but are not limited to:Design synthesis characterization and evaluation of forefront and emerging materialsUnderstanding structure property performance relationships and their underlying mechanismsDevelopment of materials for energy environmental biomedical electronic and catalytic applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信