Effects of preparation design on the marginal and internal fit of CAD-CAM overlay restorations: A µCT evaluation.

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Edoardo Mancuso, Annamaria Forte, Tatjana Maravic, Claudia Mazzitelli, Allegra Comba, Andrea Baldi, Vincent Fehmer, Irena Sailer, Nicola Scotti, Annalisa Mazzoni, Prof Lorenzo Breschi
{"title":"Effects of preparation design on the marginal and internal fit of CAD-CAM overlay restorations: A µCT evaluation.","authors":"Edoardo Mancuso, Annamaria Forte, Tatjana Maravic, Claudia Mazzitelli, Allegra Comba, Andrea Baldi, Vincent Fehmer, Irena Sailer, Nicola Scotti, Annalisa Mazzoni, Prof Lorenzo Breschi","doi":"10.1016/j.prosdent.2024.12.023","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>The effects of different finish line designs on the seating accuracy of partial indirect restorations are unclear.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to evaluate the influence of different preparation designs on the marginal and internal discrepancy of lithium disilicate computer-aided design and computer-aided manufacture (CAD-CAM) partial indirect restorations before and after thermomechanical aging by using 3-dimensional (3D) microcomputed tomography (μCT).</p><p><strong>Material and methods: </strong>Forty human molars were divided according to the preparation design and their location relative to the tooth survey line: SO: rounded shoulder occlusal to the survey line; CO: chamfer occlusal to the survey line; SA: rounded shoulder apical to the survey line; CA: chamfer apical to the survey line (n=10). Ceramic onlays were luted using a universal resin cement (RelyX Universal + Scotchbond Universal Plus). The specimens underwent thermomechanical loading in a mastication simulator (1 200 000 mechanical and 5000 thermal cycles). The marginal and internal discrepancy was evaluated with μCT before and after aging. The volume of cement and internal voids was evaluated with 3-dimensional imaging. The marginal discrepancy (MD), absolute marginal discrepancy (AMD), axial gap (AG), and occlusal gap (OG) were quantified using 2-dimensional analyses. Data were statistically analyzed using a 2-way ANOVA and the Tukey post hoc test (α=.05).</p><p><strong>Results: </strong>Preparation designs apical to the survey line resulted in a larger volume of cement compared with those occlusal to the survey line (P<.05). No differences were observed in the internal voids among the groups immediately or after aging (P>.05). Both preparation designs and aging had a significant influence on the MD, AMD, AG, and OG (P<.05). Specifically, CB exhibited significantly greater values for AMD, MD, AG, and OG compared with all other preparations (P<.05). CA and SA performed significantly worse than CO and SO in terms of AMD and MD (P<.005).</p><p><strong>Conclusions: </strong>Preparations located occlusal to the survey line, particularly CO, demonstrated superior results with respect to both marginal and internal adaptations. CA exhibited the least favorable adaptation among the preparations investigated. Aging had a detrimental impact on the marginal adaptation of the restorations, regardless of the specific preparation design used.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":" ","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2024.12.023","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem: The effects of different finish line designs on the seating accuracy of partial indirect restorations are unclear.

Purpose: The purpose of this in vitro study was to evaluate the influence of different preparation designs on the marginal and internal discrepancy of lithium disilicate computer-aided design and computer-aided manufacture (CAD-CAM) partial indirect restorations before and after thermomechanical aging by using 3-dimensional (3D) microcomputed tomography (μCT).

Material and methods: Forty human molars were divided according to the preparation design and their location relative to the tooth survey line: SO: rounded shoulder occlusal to the survey line; CO: chamfer occlusal to the survey line; SA: rounded shoulder apical to the survey line; CA: chamfer apical to the survey line (n=10). Ceramic onlays were luted using a universal resin cement (RelyX Universal + Scotchbond Universal Plus). The specimens underwent thermomechanical loading in a mastication simulator (1 200 000 mechanical and 5000 thermal cycles). The marginal and internal discrepancy was evaluated with μCT before and after aging. The volume of cement and internal voids was evaluated with 3-dimensional imaging. The marginal discrepancy (MD), absolute marginal discrepancy (AMD), axial gap (AG), and occlusal gap (OG) were quantified using 2-dimensional analyses. Data were statistically analyzed using a 2-way ANOVA and the Tukey post hoc test (α=.05).

Results: Preparation designs apical to the survey line resulted in a larger volume of cement compared with those occlusal to the survey line (P<.05). No differences were observed in the internal voids among the groups immediately or after aging (P>.05). Both preparation designs and aging had a significant influence on the MD, AMD, AG, and OG (P<.05). Specifically, CB exhibited significantly greater values for AMD, MD, AG, and OG compared with all other preparations (P<.05). CA and SA performed significantly worse than CO and SO in terms of AMD and MD (P<.005).

Conclusions: Preparations located occlusal to the survey line, particularly CO, demonstrated superior results with respect to both marginal and internal adaptations. CA exhibited the least favorable adaptation among the preparations investigated. Aging had a detrimental impact on the marginal adaptation of the restorations, regardless of the specific preparation design used.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信