{"title":"Assessment of Intraprocedural Automated Arrhythmia Origin Localization System for Localizing Pacing Sites in 3D Space.","authors":"Shijie Zhou, John Whitaker, Stanislav Goldberg, Amir AbdelWahab, William H Sauer, Jonathan Chrispin, Ronald D Berger, Harikrishna Tandri, Natalia A Trayanova, Usha B Tedrow, John L Sapp","doi":"10.1016/j.jacep.2024.12.003","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The Automated Arrhythmia Origin Localization (AAOL) algorithm was developed for real-time prediction of early ventricular activation origins on a patient-specific electroanatomic (EAM) surface using a 3-lead electrocardiogram (AAOL-Surface). It has not been evaluated in 3-dimensional (3D) space (AAOL-3D), however, which may be important for predicting the arrhythmia origin from intramural or intracavity sites.</p><p><strong>Objectives: </strong>This study sought to assess the accuracy of AAOL for localizing earliest ventricular activation in 3D space.</p><p><strong>Methods: </strong>This was a retrospective study of 3 datasets (BWH [Brigham and Women's Hospital], JHH [Johns Hopkins Hospital], and QEII [Queen Elizabeth II Health Sciences Centre]) involving 47 patients and 48 procedures, with an average of 19 ± 10 pacing sites each. In each patient, individual pacing sites were identified as target sites; the remaining pacing sites served as a training set (including QRS integrals from leads III, V<sub>2</sub>, and V<sub>6</sub> with associated 3D coordinates). The AAOL-3D was then used to predict 3D coordinates of the pacing site. Localization error was assessed as the distance between known and predicted site coordinates, considering different EAM resolutions.</p><p><strong>Results: </strong>The AAOL-3D achieved a localization accuracy of 7.2 ± 3.1 mm, outperforming the AAOL-Surface (7.2 vs 7.8 mm; P < 0.05), with greater localization error for epicardial than endocardial pacing sites (8.7 vs 7.1 mm; P < 0.05). Cohort-specific analysis consistently favored AAOL-3D over AAOL-Surface in terms of accuracy. Exploration of AAOL-Surface accuracy across varying EAM resolutions showed optimal performance at the original and 75% resolution, with performance declining as resolution decreased.</p><p><strong>Conclusions: </strong>The AAOL approach accurately identifies early ventricular activation origins in 3D and on EAM surfaces, potentially useful for identifying intramural arrhythmia origins.</p>","PeriodicalId":14573,"journal":{"name":"JACC. Clinical electrophysiology","volume":" ","pages":""},"PeriodicalIF":8.0000,"publicationDate":"2025-01-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JACC. Clinical electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jacep.2024.12.003","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The Automated Arrhythmia Origin Localization (AAOL) algorithm was developed for real-time prediction of early ventricular activation origins on a patient-specific electroanatomic (EAM) surface using a 3-lead electrocardiogram (AAOL-Surface). It has not been evaluated in 3-dimensional (3D) space (AAOL-3D), however, which may be important for predicting the arrhythmia origin from intramural or intracavity sites.

Objectives: This study sought to assess the accuracy of AAOL for localizing earliest ventricular activation in 3D space.

Methods: This was a retrospective study of 3 datasets (BWH [Brigham and Women's Hospital], JHH [Johns Hopkins Hospital], and QEII [Queen Elizabeth II Health Sciences Centre]) involving 47 patients and 48 procedures, with an average of 19 ± 10 pacing sites each. In each patient, individual pacing sites were identified as target sites; the remaining pacing sites served as a training set (including QRS integrals from leads III, V2, and V6 with associated 3D coordinates). The AAOL-3D was then used to predict 3D coordinates of the pacing site. Localization error was assessed as the distance between known and predicted site coordinates, considering different EAM resolutions.

Results: The AAOL-3D achieved a localization accuracy of 7.2 ± 3.1 mm, outperforming the AAOL-Surface (7.2 vs 7.8 mm; P < 0.05), with greater localization error for epicardial than endocardial pacing sites (8.7 vs 7.1 mm; P < 0.05). Cohort-specific analysis consistently favored AAOL-3D over AAOL-Surface in terms of accuracy. Exploration of AAOL-Surface accuracy across varying EAM resolutions showed optimal performance at the original and 75% resolution, with performance declining as resolution decreased.

Conclusions: The AAOL approach accurately identifies early ventricular activation origins in 3D and on EAM surfaces, potentially useful for identifying intramural arrhythmia origins.

求助全文
约1分钟内获得全文 求助全文
来源期刊
JACC. Clinical electrophysiology
JACC. Clinical electrophysiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
10.30
自引率
5.70%
发文量
250
期刊介绍: JACC: Clinical Electrophysiology is one of a family of specialist journals launched by the renowned Journal of the American College of Cardiology (JACC). It encompasses all aspects of the epidemiology, pathogenesis, diagnosis and treatment of cardiac arrhythmias. Submissions of original research and state-of-the-art reviews from cardiology, cardiovascular surgery, neurology, outcomes research, and related fields are encouraged. Experimental and preclinical work that directly relates to diagnostic or therapeutic interventions are also encouraged. In general, case reports will not be considered for publication.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信