{"title":"Detection of Cholesterol Crystals Using the Filter Paper Rinse Method in Very Late Stent Thrombosis Cases.","authors":"Saki Mizobuchi, Keisuke Kojima, Yudai Tanaka, Yuta Hotsubo, Shohei Migita, Masatsugu Miyagawa, Katsunori Fukumoto, Yuki Nakajima, Yasunari Ebuchi, Riku Arai, Tomoyuki Morikawa, Takashi Mineki, Nobuhiro Murata, Daisuke Fukamachi, Yasuo Okumura","doi":"10.1536/ihj.24-450","DOIUrl":null,"url":null,"abstract":"<p><p>Very late stent thrombosis (VLST) is a rare but critical complication of stent placement. In this report, we present 2 VLST cases diagnosed with neoatherosclerosis by detecting cholesterol crystals (CCs) via the filter paper rinse method. In terms of differentiating between neoatherosclerosis and stent thrombosis. There was no visible thrombus observed on thrombus aspiration. Examination of the blood sample obtained from the thrombus aspiration using the filter paper rinse method showed the presence of CCs under polarized light microscopy, thus, diagnosing VLST caused by neoatherosclerosis. Diagnosis of neoatherosclerosis would provide a rationale for intensive lipid-lowering therapy.</p>","PeriodicalId":13711,"journal":{"name":"International heart journal","volume":"66 1","pages":"175-178"},"PeriodicalIF":1.2000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International heart journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1536/ihj.24-450","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Very late stent thrombosis (VLST) is a rare but critical complication of stent placement. In this report, we present 2 VLST cases diagnosed with neoatherosclerosis by detecting cholesterol crystals (CCs) via the filter paper rinse method. In terms of differentiating between neoatherosclerosis and stent thrombosis. There was no visible thrombus observed on thrombus aspiration. Examination of the blood sample obtained from the thrombus aspiration using the filter paper rinse method showed the presence of CCs under polarized light microscopy, thus, diagnosing VLST caused by neoatherosclerosis. Diagnosis of neoatherosclerosis would provide a rationale for intensive lipid-lowering therapy.
期刊介绍:
Authors of research articles should disclose at the time of submission any financial arrangement they may have with a company whose product figures prominently in the submitted manuscript or with a company making a competing product. Such information will be held in confidence while the paper is under review and will not influence the editorial decision, but if the article is accepted for publication, the editors will usually discuss with the authors the manner in which such information is to be communicated to the reader.