Thermal Changes During Digital Guided Implant Surgery Using the Conventional and Single Drill Protocols.

Aritza Brizuela-Velasco, Daniel Robles, Saray Fernández-Hernández, José Manuel Mendes, Ignacio Sanz, Javier Gil
{"title":"Thermal Changes During Digital Guided Implant Surgery Using the Conventional and Single Drill Protocols.","authors":"Aritza Brizuela-Velasco, Daniel Robles, Saray Fernández-Hernández, José Manuel Mendes, Ignacio Sanz, Javier Gil","doi":"10.11607/jomi.11066","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to compare heat generation during osteotomy for dental implant placement using conventional (sequential drilling) and single drill protocol in digitally guided surgery and to clarify differences in thermal exposure time.</p><p><strong>Materials and methods: </strong>In this study, we used a bovine rib ex vivo model with a surgical splint and a type K thermocouple to measure temperature and time. The conventional protocol (n=20) involved sequential drilling using 6 drills of increasing diameter, while the simplified protocol used a single drill (n=20). On the other hand, four implant beds were prepared in the tibia of a New Zealand rabbit to compare the mean temperature values between the in vivo and ex vivo models.</p><p><strong>Results: </strong>Student's t-test revealed no significant differences (p=0.1688) in temperature elevation between the conventional drilling (mean, 1.977°C; sd 1.165) and single drilling (mean, 2.634°C; sd 1.734) protocols. However, significant differences between the groups were found in the exposure time: 107.105 seconds (sd 29.196) and 16.842 (sd 8.101) respectively. The mean temperature increase due to drilling was 0.365°C (sd 0.204) and 0.378°C (sd 0.381) in the rabbit tibia and bovine rib, respectively, with no significant differences (p-value = 0.926) between the in vivo and ex vivo models.</p><p><strong>Conclusions: </strong>Conventional and single drill guided surgery protocols for implant bed preparation generate similar temperatures in vitro. Exposure time is longer with conventional protocols than with single drill protocols.</p>","PeriodicalId":94230,"journal":{"name":"The International journal of oral & maxillofacial implants","volume":"0 0","pages":"1-22"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of oral & maxillofacial implants","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/jomi.11066","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The aim of this study was to compare heat generation during osteotomy for dental implant placement using conventional (sequential drilling) and single drill protocol in digitally guided surgery and to clarify differences in thermal exposure time.

Materials and methods: In this study, we used a bovine rib ex vivo model with a surgical splint and a type K thermocouple to measure temperature and time. The conventional protocol (n=20) involved sequential drilling using 6 drills of increasing diameter, while the simplified protocol used a single drill (n=20). On the other hand, four implant beds were prepared in the tibia of a New Zealand rabbit to compare the mean temperature values between the in vivo and ex vivo models.

Results: Student's t-test revealed no significant differences (p=0.1688) in temperature elevation between the conventional drilling (mean, 1.977°C; sd 1.165) and single drilling (mean, 2.634°C; sd 1.734) protocols. However, significant differences between the groups were found in the exposure time: 107.105 seconds (sd 29.196) and 16.842 (sd 8.101) respectively. The mean temperature increase due to drilling was 0.365°C (sd 0.204) and 0.378°C (sd 0.381) in the rabbit tibia and bovine rib, respectively, with no significant differences (p-value = 0.926) between the in vivo and ex vivo models.

Conclusions: Conventional and single drill guided surgery protocols for implant bed preparation generate similar temperatures in vitro. Exposure time is longer with conventional protocols than with single drill protocols.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信