Reproducibility of peak force for isometric and isokinetic multi-joint leg extension exercise.

IF 2.1 3区 医学 Q1 REHABILITATION
Manfred Zöger, Alfred Nimmerichter, Arnold Baca, Klaus Wirth
{"title":"Reproducibility of peak force for isometric and isokinetic multi-joint leg extension exercise.","authors":"Manfred Zöger, Alfred Nimmerichter, Arnold Baca, Klaus Wirth","doi":"10.1186/s13102-025-01061-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Isokinetic dynamometry is a common tool for evaluating muscle function and is used across various disciplines. Technical advancements have shifted focus towards multi-joint exercises such as the leg press, offering insights into practical human movement dynamics. However, previous reproducibility studies have focused predominantly on single-joint exercises, warranting investigations into the reliability of multi-joint exercises. This study aimed to assess the reproducibility of peak force (PF) during multi-joint leg press exercises using the IsoMed 2000 dynamometer.</p><p><strong>Methods: </strong>Thirty physically active subjects (mean: stature 179.4 cm; body mass 76.0 kg; age 30.6 years) participated in three testing sessions. Each session consisted of isometric and isokinetic leg press exercises. Knee angles for isometric exercises included 100° and 140°; velocities for isokinetic exercise included 30 mm/s and 600 mm/s. The first session served as the familiarization session. Statistical analysis included paired sample t-tests, Cohen's d effect sizes, intraclass correlation coefficients (ICC), standard errors of measurement (SEM), and Bland-Altman calculations, including corresponding plots.</p><p><strong>Results: </strong>Descriptive data revealed consistent PF across sessions, with a significant between-sessions difference observed only for isometric (100°) leg extension in the right leg (p < 0.001; d = 0.13). ICC calculations showed high relative reproducibility (ICC > 0.911), with SEM ranging from 37.6 to 294.7 N (SEM% 2.3-6.3%, respectively). Bland-Altman plots depicted minimal intersession disparities (-141.8-68.3 N, respectively - 3.02-1.26%), supporting high reliability.</p><p><strong>Conclusions: </strong>This study highlights the reliability of assessing peak force during isometric and isokinetic leg press exercises using the IsoMed 2000 after a single familiarization session. These findings support its utility in muscular performance evaluation, urging practitioners to incorporate familiarization trials for accurate assessments.</p>","PeriodicalId":48585,"journal":{"name":"BMC Sports Science Medicine and Rehabilitation","volume":"17 1","pages":"14"},"PeriodicalIF":2.1000,"publicationDate":"2025-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11776222/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Sports Science Medicine and Rehabilitation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13102-025-01061-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Isokinetic dynamometry is a common tool for evaluating muscle function and is used across various disciplines. Technical advancements have shifted focus towards multi-joint exercises such as the leg press, offering insights into practical human movement dynamics. However, previous reproducibility studies have focused predominantly on single-joint exercises, warranting investigations into the reliability of multi-joint exercises. This study aimed to assess the reproducibility of peak force (PF) during multi-joint leg press exercises using the IsoMed 2000 dynamometer.

Methods: Thirty physically active subjects (mean: stature 179.4 cm; body mass 76.0 kg; age 30.6 years) participated in three testing sessions. Each session consisted of isometric and isokinetic leg press exercises. Knee angles for isometric exercises included 100° and 140°; velocities for isokinetic exercise included 30 mm/s and 600 mm/s. The first session served as the familiarization session. Statistical analysis included paired sample t-tests, Cohen's d effect sizes, intraclass correlation coefficients (ICC), standard errors of measurement (SEM), and Bland-Altman calculations, including corresponding plots.

Results: Descriptive data revealed consistent PF across sessions, with a significant between-sessions difference observed only for isometric (100°) leg extension in the right leg (p < 0.001; d = 0.13). ICC calculations showed high relative reproducibility (ICC > 0.911), with SEM ranging from 37.6 to 294.7 N (SEM% 2.3-6.3%, respectively). Bland-Altman plots depicted minimal intersession disparities (-141.8-68.3 N, respectively - 3.02-1.26%), supporting high reliability.

Conclusions: This study highlights the reliability of assessing peak force during isometric and isokinetic leg press exercises using the IsoMed 2000 after a single familiarization session. These findings support its utility in muscular performance evaluation, urging practitioners to incorporate familiarization trials for accurate assessments.

背景:等动测力法是评估肌肉功能的常用工具,被广泛应用于各个学科。技术的进步已将重点转向压腿等多关节练习,从而为实际的人体运动动力学提供了洞察力。然而,以往的再现性研究主要集中在单关节练习上,因此有必要对多关节练习的可靠性进行研究。本研究旨在使用 IsoMed 2000 测功机评估多关节压腿练习中峰值力(PF)的再现性:30 名身体活跃的受试者(平均身高 179.4 厘米;体重 76.0 千克;年龄 30.6 岁)参加了三次测试。每次测试包括等长和等速压腿练习。等长练习的膝关节角度包括 100° 和 140°;等速练习的速度包括 30 毫米/秒和 600 毫米/秒。第一节为熟悉环节。统计分析包括配对样本 t 检验、Cohen's d 效果大小、类内相关系数 (ICC)、测量标准误差 (SEM) 和 Bland-Altman 计算,包括相应的绘图:描述性数据显示,各次训练的 PF 值一致,只有右腿等长(100°)伸腿的 PF 值在各次训练之间存在显著差异(p 0.911),SEM 值范围为 37.6 至 294.7 N(SEM% 分别为 2.3 至 6.3%)。Bland-Altman图显示,各节之间的差异极小(-141.8-68.3 N,分别为-3.02-1.26%),支持高可靠性:本研究强调了使用 IsoMed 2000 在一次熟悉训练后评估等长和等动压腿练习中峰值力的可靠性。这些研究结果支持其在肌肉性能评估中的实用性,并敦促从业人员进行熟悉试验,以获得准确的评估结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Sports Science Medicine and Rehabilitation
BMC Sports Science Medicine and Rehabilitation Medicine-Orthopedics and Sports Medicine
CiteScore
3.00
自引率
5.30%
发文量
196
审稿时长
26 weeks
期刊介绍: BMC Sports Science, Medicine and Rehabilitation is an open access, peer reviewed journal that considers articles on all aspects of sports medicine and the exercise sciences, including rehabilitation, traumatology, cardiology, physiology, and nutrition.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信