Feasibility of generating sagittal radiographs from coronal views using GAN-based deep learning framework in adolescent idiopathic scoliosis.

IF 3.7 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Tito Bassani, Andrea Cina, Fabio Galbusera, Andrea Cazzato, Maria Elena Pellegrino, Domenico Albano, Luca Maria Sconfienza
{"title":"Feasibility of generating sagittal radiographs from coronal views using GAN-based deep learning framework in adolescent idiopathic scoliosis.","authors":"Tito Bassani, Andrea Cina, Fabio Galbusera, Andrea Cazzato, Maria Elena Pellegrino, Domenico Albano, Luca Maria Sconfienza","doi":"10.1186/s41747-025-00553-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Minimizing radiation exposure is crucial in monitoring adolescent idiopathic scoliosis (AIS). Generative adversarial networks (GANs) have emerged as valuable tools being able to generate high-quality synthetic images. This study explores the use of GANs to generate synthetic sagittal radiographs from coronal views in AIS patients.</p><p><strong>Methods: </strong>A dataset of 3,935 AIS patients who underwent spine and pelvis radiographic examinations using the EOS system, which simultaneously acquires coronal and sagittal images, was analyzed. The dataset was divided into training-set (85%, n = 3,356) and test-set (15%, n = 579). GAN model was trained to generate sagittal images from coronal views, with real sagittal views as reference standard. To assess accuracy, 100 subjects from the test-set were randomly selected for manual measurement of lumbar lordosis (LL), sacral slope (SS), pelvic incidence (PI), and sagittal vertical axis (SVA) by two radiologists in both synthetic and real images.</p><p><strong>Results: </strong>Sixty-nine synthetic images were considered assessable. The intraclass correlation coefficient ranged 0.93-0.99 for measurements in real images, and from 0.83 to 0.88 for synthetic images. Correlations between parameters of real and synthetic images were 0.52 (LL), 0.17 (SS), 0.18 (PI), and 0.74 (SVA). Measurement errors showed minimal correlation with scoliosis severity. Mean ± standard deviation absolute errors were 7 ± 7° (LL), 9 ± 7° (SS), 9 ± 8° (PI), and 1.1 ± 0.8 cm (SVA).</p><p><strong>Conclusion: </strong>While the model generates sagittal images visually consistent with reference images, their quality is not sufficient for clinical parameter assessment, except for promising results in SVA.</p><p><strong>Relevance statement: </strong>AI can generate synthetic sagittal radiographs from coronal views to reduce radiation exposure in monitoring adolescent idiopathic scoliosis (AIS). However, while these synthetic images appear visually consistent with real ones, their quality remains insufficient for accurate clinical assessment.</p><p><strong>Key points: </strong>AI can be exploited to generate synthetic sagittal radiographs from coronal views. Dataset of 3,935 subjects was used to train and test AI-model; spinal parameters from synthetic and real images were compared. Synthetic images were visually consistent with real ones, but quality was generally insufficient for accurate clinical assessment.</p>","PeriodicalId":36926,"journal":{"name":"European Radiology Experimental","volume":"9 1","pages":"11"},"PeriodicalIF":3.7000,"publicationDate":"2025-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11780070/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Radiology Experimental","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s41747-025-00553-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Minimizing radiation exposure is crucial in monitoring adolescent idiopathic scoliosis (AIS). Generative adversarial networks (GANs) have emerged as valuable tools being able to generate high-quality synthetic images. This study explores the use of GANs to generate synthetic sagittal radiographs from coronal views in AIS patients.

Methods: A dataset of 3,935 AIS patients who underwent spine and pelvis radiographic examinations using the EOS system, which simultaneously acquires coronal and sagittal images, was analyzed. The dataset was divided into training-set (85%, n = 3,356) and test-set (15%, n = 579). GAN model was trained to generate sagittal images from coronal views, with real sagittal views as reference standard. To assess accuracy, 100 subjects from the test-set were randomly selected for manual measurement of lumbar lordosis (LL), sacral slope (SS), pelvic incidence (PI), and sagittal vertical axis (SVA) by two radiologists in both synthetic and real images.

Results: Sixty-nine synthetic images were considered assessable. The intraclass correlation coefficient ranged 0.93-0.99 for measurements in real images, and from 0.83 to 0.88 for synthetic images. Correlations between parameters of real and synthetic images were 0.52 (LL), 0.17 (SS), 0.18 (PI), and 0.74 (SVA). Measurement errors showed minimal correlation with scoliosis severity. Mean ± standard deviation absolute errors were 7 ± 7° (LL), 9 ± 7° (SS), 9 ± 8° (PI), and 1.1 ± 0.8 cm (SVA).

Conclusion: While the model generates sagittal images visually consistent with reference images, their quality is not sufficient for clinical parameter assessment, except for promising results in SVA.

Relevance statement: AI can generate synthetic sagittal radiographs from coronal views to reduce radiation exposure in monitoring adolescent idiopathic scoliosis (AIS). However, while these synthetic images appear visually consistent with real ones, their quality remains insufficient for accurate clinical assessment.

Key points: AI can be exploited to generate synthetic sagittal radiographs from coronal views. Dataset of 3,935 subjects was used to train and test AI-model; spinal parameters from synthetic and real images were compared. Synthetic images were visually consistent with real ones, but quality was generally insufficient for accurate clinical assessment.

求助全文
约1分钟内获得全文 求助全文
来源期刊
European Radiology Experimental
European Radiology Experimental Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
6.70
自引率
2.60%
发文量
56
审稿时长
18 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信