Spatial displacement on three-dimensional maps caused by rhythm differences in premature ventricular contraction ablation.

Q3 Medicine
Yusuke Sakamoto, Hiroyuki Osanai, Yoshihito Nakashima, Hiroshi Asano
{"title":"Spatial displacement on three-dimensional maps caused by rhythm differences in premature ventricular contraction ablation.","authors":"Yusuke Sakamoto, Hiroyuki Osanai, Yoshihito Nakashima, Hiroshi Asano","doi":"10.1016/j.ipej.2025.01.004","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Three-dimensional (3D) maps are useful for premature ventricular contraction (PVC) ablation. However, positional information changes compared with sinus rhythm when PVCs appear, rendering ablation difficult. We aimed to understand the spatial displacement characteristics of PVC ablation in 3D maps and the therapeutic effect after correction using the LAT-Hybrid function.</p><p><strong>Methods: </strong>Thirty-two consecutive patients who underwent PVC ablation from 2022 to 2024 were included. Parallel mapping was used to analyze the LAT-Hybrid function. Ablation was performed at the best Hybrid-LAT location. Characteristics according to PVC origin (right ventricular outflow tract, ventricular septum, and left ventricular outflow tract/left ventricular summit) were compared. Efficacy was evaluated by acute response and clinical outcome on 24-h Holter after 6 months.</p><p><strong>Results: </strong>In all cases, the PVC origin was spatially displaced by 5.6 ± 1.9 (right ventricular outflow tract, 6.0 ± 1.8; ventricular septum, 4.0 ± 1.4; left ventricular outflow tract/left ventricular summit, 6.0 ± 1.7) mm, and the septum area was significantly smaller. The voltage of origin was 60 % in the low voltage-transitional zone, which coincided with 80 % of the origin determined from the ripple map. The pace map at the location analyzed with LAT-Hybrid was high at 95.4 % ± 3.6 %, and ablation was successful in 96.9 % at the same site. The clinical outcome was good 6 months after ablation.</p><p><strong>Conclusion: </strong>Spatial displacement of the 3D map caused by differences in excitation propagation can lead to misidentification of the origin. PVC ablation corrects spatial displacement and obtains accurate positional information, leading to successful ablation.</p>","PeriodicalId":35900,"journal":{"name":"Indian Pacing and Electrophysiology Journal","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-01-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Pacing and Electrophysiology Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.ipej.2025.01.004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Three-dimensional (3D) maps are useful for premature ventricular contraction (PVC) ablation. However, positional information changes compared with sinus rhythm when PVCs appear, rendering ablation difficult. We aimed to understand the spatial displacement characteristics of PVC ablation in 3D maps and the therapeutic effect after correction using the LAT-Hybrid function.

Methods: Thirty-two consecutive patients who underwent PVC ablation from 2022 to 2024 were included. Parallel mapping was used to analyze the LAT-Hybrid function. Ablation was performed at the best Hybrid-LAT location. Characteristics according to PVC origin (right ventricular outflow tract, ventricular septum, and left ventricular outflow tract/left ventricular summit) were compared. Efficacy was evaluated by acute response and clinical outcome on 24-h Holter after 6 months.

Results: In all cases, the PVC origin was spatially displaced by 5.6 ± 1.9 (right ventricular outflow tract, 6.0 ± 1.8; ventricular septum, 4.0 ± 1.4; left ventricular outflow tract/left ventricular summit, 6.0 ± 1.7) mm, and the septum area was significantly smaller. The voltage of origin was 60 % in the low voltage-transitional zone, which coincided with 80 % of the origin determined from the ripple map. The pace map at the location analyzed with LAT-Hybrid was high at 95.4 % ± 3.6 %, and ablation was successful in 96.9 % at the same site. The clinical outcome was good 6 months after ablation.

Conclusion: Spatial displacement of the 3D map caused by differences in excitation propagation can lead to misidentification of the origin. PVC ablation corrects spatial displacement and obtains accurate positional information, leading to successful ablation.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Indian Pacing and Electrophysiology Journal
Indian Pacing and Electrophysiology Journal Medicine-Cardiology and Cardiovascular Medicine
CiteScore
2.20
自引率
0.00%
发文量
91
审稿时长
61 days
期刊介绍: Indian Pacing and Electrophysiology Journal is a peer reviewed online journal devoted to cardiac pacing and electrophysiology. Editorial Advisory Board includes eminent personalities in the field of cardiac pacing and electrophysiology from Asia, Australia, Europe and North America.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信