Measurement of Whole Blood Tacrolimus Concentrations by LC-MS/MS and Immunoassay Methods: Influence of Immediate-Release vs Extended-Release Tacrolimus Formulations.

IF 1.8 Q3 MEDICAL LABORATORY TECHNOLOGY
Adekunle Alabi, Mengyuan Ge, Jeremiah D Momper, Shirley M Tsunoda, Michael J Kelner, Robert L Fitzgerald, Raymond T Suhandynata
{"title":"Measurement of Whole Blood Tacrolimus Concentrations by LC-MS/MS and Immunoassay Methods: Influence of Immediate-Release vs Extended-Release Tacrolimus Formulations.","authors":"Adekunle Alabi, Mengyuan Ge, Jeremiah D Momper, Shirley M Tsunoda, Michael J Kelner, Robert L Fitzgerald, Raymond T Suhandynata","doi":"10.1093/jalm/jfae156","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Therapeutic drug monitoring of the immunosuppressant tacrolimus is commonly performed by immunoassay or LC-MS/MS. Measurement biases between these methodologies have been characterized for immediate-release tacrolimus (IR-tac; Prograf) but have not been performed for extended-release formulations such as Envarsus. These discrepancies can impact patient care, as appropriate dosing is required to maintain therapeutic concentrations and immunosuppression.</p><p><strong>Methods: </strong>Validation of a whole-blood LC-MS/MS method for the simultaneous quantification of tacrolimus and its major metabolite, desmethyl tacrolimus, was performed using traceable calibrators (tacrolimus, ERM-DA110a) and quality control (QC) material for tacrolimus and standard material for desmethyl tacrolimus. Tacrolimus concentrations were determined by LC-MS/MS and the ARCHITECT immunoassay in patients receiving either IR-tac or Envarsus for clinical care.</p><p><strong>Results: </strong>External calibration curves for both tacrolimus and desmethyl tacrolimus were linear (R2 > 0.995), and the analytical measurement range (AMR) for tacrolimus spanned from 1.1 to 31.6 ng/mL. Calibrator/QC biases were within 15% of their spiked concentrations throughout the AMR, and within-run imprecision was <10%, except at the lower limit of quantification (n = 25). Between-run imprecision for low, mid, and high QC levels was ≤11% over a 2-week period (n = 5 days). Comparative biases between immunoassay and LC-MS/MS were significantly lower (P = 0.0074) for patients receiving Envarsus (n = 20 specimens) relative to patients receiving IR-tac (n = 32 specimens).</p><p><strong>Conclusions: </strong>Biases between immunoassay and LC-MS/MS tacrolimus measurements in patients receiving immediate-release vs extended-release formulations indicate that their distinct pharmacokinetic profiles impact measurement accuracy. These assay biases should be considered when interpreting tacrolimus concentration measurements.</p>","PeriodicalId":46361,"journal":{"name":"Journal of Applied Laboratory Medicine","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jalm/jfae156","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Therapeutic drug monitoring of the immunosuppressant tacrolimus is commonly performed by immunoassay or LC-MS/MS. Measurement biases between these methodologies have been characterized for immediate-release tacrolimus (IR-tac; Prograf) but have not been performed for extended-release formulations such as Envarsus. These discrepancies can impact patient care, as appropriate dosing is required to maintain therapeutic concentrations and immunosuppression.

Methods: Validation of a whole-blood LC-MS/MS method for the simultaneous quantification of tacrolimus and its major metabolite, desmethyl tacrolimus, was performed using traceable calibrators (tacrolimus, ERM-DA110a) and quality control (QC) material for tacrolimus and standard material for desmethyl tacrolimus. Tacrolimus concentrations were determined by LC-MS/MS and the ARCHITECT immunoassay in patients receiving either IR-tac or Envarsus for clinical care.

Results: External calibration curves for both tacrolimus and desmethyl tacrolimus were linear (R2 > 0.995), and the analytical measurement range (AMR) for tacrolimus spanned from 1.1 to 31.6 ng/mL. Calibrator/QC biases were within 15% of their spiked concentrations throughout the AMR, and within-run imprecision was <10%, except at the lower limit of quantification (n = 25). Between-run imprecision for low, mid, and high QC levels was ≤11% over a 2-week period (n = 5 days). Comparative biases between immunoassay and LC-MS/MS were significantly lower (P = 0.0074) for patients receiving Envarsus (n = 20 specimens) relative to patients receiving IR-tac (n = 32 specimens).

Conclusions: Biases between immunoassay and LC-MS/MS tacrolimus measurements in patients receiving immediate-release vs extended-release formulations indicate that their distinct pharmacokinetic profiles impact measurement accuracy. These assay biases should be considered when interpreting tacrolimus concentration measurements.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Applied Laboratory Medicine
Journal of Applied Laboratory Medicine MEDICAL LABORATORY TECHNOLOGY-
CiteScore
3.70
自引率
5.00%
发文量
137
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信