Comparison of water exchange measurements between filter-exchange imaging and diffusion time-dependent kurtosis imaging in the human brain.

IF 3 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Zhaoqing Li, Chunjing Liang, Qingping He, Thorsten Feiweier, Yi-Cheng Hsu, Jianhua Li, Ruiliang Bai
{"title":"Comparison of water exchange measurements between filter-exchange imaging and diffusion time-dependent kurtosis imaging in the human brain.","authors":"Zhaoqing Li, Chunjing Liang, Qingping He, Thorsten Feiweier, Yi-Cheng Hsu, Jianhua Li, Ruiliang Bai","doi":"10.1002/mrm.30454","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Filter-exchange imaging (FEXI) and diffusion time (t)-dependent kurtosis imaging (DKI(t)) are two diffusion-based methods that have been proposed for in vivo measurements of water exchange rates. Few studies have directly compared these methods. We aimed to investigate whether FEXI and DKI(t) yield comparable water exchange measurements in the human brain in vivo.</p><p><strong>Methods: </strong>Eight healthy volunteers underwent multiple-direction FEXI and DKI(t) acquisitions on a 3T scanner. We performed region of interest (ROI) analysis to determine correlations between FEXI-derived apparent exchange rate (AXR) and DKI(t)-derived reciprocal of exchange time ( <math> <semantics><mrow><mn>1</mn> <mo>/</mo> <msub><mi>τ</mi> <mi>ex</mi></msub> </mrow> <annotation>$$ 1/{\\tau}_{ex} $$</annotation></semantics> </math> ).</p><p><strong>Results: </strong>In both white matter (WM) and gray matter (GM), DKI(t) revealed substantial diffusion-time dependence of diffusivity and kurtosis. However, at t ≥ 100 ms, the diffusivity showed weak time dependence. In WM, this time dependence may be due to water exchange between myelin water and \"free\" water with different T<sub>1</sub> values, although other factors, such as remaining restrictive effects from microstructural barriers, cannot be excluded. We found a significant correlation between DKI(t)-derived <math> <semantics><mrow><mn>1</mn> <mo>/</mo> <msub><mi>τ</mi> <mi>ex</mi></msub> </mrow> <annotation>$$ 1/{\\tau}_{ex} $$</annotation></semantics> </math> and FEXI-derived AXR in the axial direction within WM. No such correlation was present in GM, although both values showed similar ranges.</p><p><strong>Conclusion: </strong>These results suggest that FEXI and DKI(t) could be sensitive to the same water exchange process only when the diffusion time in DKI(t) is sufficiently long, and only in WM. In both GM and WM, the restrictive effect of microstructure is non-negligible, especially at short diffusion times (<100 ms).</p>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/mrm.30454","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Filter-exchange imaging (FEXI) and diffusion time (t)-dependent kurtosis imaging (DKI(t)) are two diffusion-based methods that have been proposed for in vivo measurements of water exchange rates. Few studies have directly compared these methods. We aimed to investigate whether FEXI and DKI(t) yield comparable water exchange measurements in the human brain in vivo.

Methods: Eight healthy volunteers underwent multiple-direction FEXI and DKI(t) acquisitions on a 3T scanner. We performed region of interest (ROI) analysis to determine correlations between FEXI-derived apparent exchange rate (AXR) and DKI(t)-derived reciprocal of exchange time ( 1 / τ ex $$ 1/{\tau}_{ex} $$ ).

Results: In both white matter (WM) and gray matter (GM), DKI(t) revealed substantial diffusion-time dependence of diffusivity and kurtosis. However, at t ≥ 100 ms, the diffusivity showed weak time dependence. In WM, this time dependence may be due to water exchange between myelin water and "free" water with different T1 values, although other factors, such as remaining restrictive effects from microstructural barriers, cannot be excluded. We found a significant correlation between DKI(t)-derived 1 / τ ex $$ 1/{\tau}_{ex} $$ and FEXI-derived AXR in the axial direction within WM. No such correlation was present in GM, although both values showed similar ranges.

Conclusion: These results suggest that FEXI and DKI(t) could be sensitive to the same water exchange process only when the diffusion time in DKI(t) is sufficiently long, and only in WM. In both GM and WM, the restrictive effect of microstructure is non-negligible, especially at short diffusion times (<100 ms).

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.70
自引率
24.20%
发文量
376
审稿时长
2-4 weeks
期刊介绍: Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信