{"title":"Reverse Torque and Wear of Internal Connections of Metal-Based Abutments Under Cyclic Loading","authors":"Daher Antonio Queiroz, Mariana Itaborai Moreira Freitas, Kaden Thomas Ockey, Damian Jaewhan Lee, Fengyuan Zheng","doi":"10.1111/jerd.13425","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objective</h3>\n \n <p>Evaluate the reverse torque values and wear of internal connections caused by metal-based zirconia abutments under cyclic loading.</p>\n </section>\n \n <section>\n \n <h3> Material and Methods</h3>\n \n <p>Thirty implants were divided into three groups (<i>n</i> = 10), based on connection systems: Interference-fit cone-screw (Cortical Master Flash MI Fit—MTA and Cortical Master Flash MI RP—MTB), and Internal hexagon (Cortical Titanium Master Connect AR—IH). Metal-based zirconia abutments were tightened into the implant, and zirconia crowns were bonded using resin cement. All specimens underwent cyclic loading at 300 N and 9 Hz for 1,000,000 cycles. Reverse torques were assessed postloading, and wear was analyzed using scanning electron microscopy (SEM). Statistical analysis employed one-way ANOVA for reverse torque and wear values, with significant differences assessed via the Tukey test (<i>α</i> = 0.05).</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Significant differences in reverse torque values were found among groups: MTA (24.9 N), MTB (24.1 N), and IH (14.4 N). The IH group showed higher mean wear values on the tension side (121.0) and compression side (112.6), with a wear difference of 8.4.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>The interference-fit cone-screw abutments demonstrated significantly reduced torque loss and morphology after cyclic loading, reflecting enhanced performance.</p>\n </section>\n \n <section>\n \n <h3> Clinical Significance</h3>\n \n <p>Although the stability of the metal base zirconia abutments to the implants was accurate, clinicians should be cautious about torque loss and more wear when using internal hexagon connections.</p>\n </section>\n </div>","PeriodicalId":15988,"journal":{"name":"Journal of Esthetic and Restorative Dentistry","volume":"37 6","pages":"1539-1545"},"PeriodicalIF":3.2000,"publicationDate":"2025-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Esthetic and Restorative Dentistry","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jerd.13425","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
Evaluate the reverse torque values and wear of internal connections caused by metal-based zirconia abutments under cyclic loading.
Material and Methods
Thirty implants were divided into three groups (n = 10), based on connection systems: Interference-fit cone-screw (Cortical Master Flash MI Fit—MTA and Cortical Master Flash MI RP—MTB), and Internal hexagon (Cortical Titanium Master Connect AR—IH). Metal-based zirconia abutments were tightened into the implant, and zirconia crowns were bonded using resin cement. All specimens underwent cyclic loading at 300 N and 9 Hz for 1,000,000 cycles. Reverse torques were assessed postloading, and wear was analyzed using scanning electron microscopy (SEM). Statistical analysis employed one-way ANOVA for reverse torque and wear values, with significant differences assessed via the Tukey test (α = 0.05).
Results
Significant differences in reverse torque values were found among groups: MTA (24.9 N), MTB (24.1 N), and IH (14.4 N). The IH group showed higher mean wear values on the tension side (121.0) and compression side (112.6), with a wear difference of 8.4.
Conclusion
The interference-fit cone-screw abutments demonstrated significantly reduced torque loss and morphology after cyclic loading, reflecting enhanced performance.
Clinical Significance
Although the stability of the metal base zirconia abutments to the implants was accurate, clinicians should be cautious about torque loss and more wear when using internal hexagon connections.
期刊介绍:
The Journal of Esthetic and Restorative Dentistry (JERD) is the longest standing peer-reviewed journal devoted solely to advancing the knowledge and practice of esthetic dentistry. Its goal is to provide the very latest evidence-based information in the realm of contemporary interdisciplinary esthetic dentistry through high quality clinical papers, sound research reports and educational features.
The range of topics covered in the journal includes:
- Interdisciplinary esthetic concepts
- Implants
- Conservative adhesive restorations
- Tooth Whitening
- Prosthodontic materials and techniques
- Dental materials
- Orthodontic, periodontal and endodontic esthetics
- Esthetics related research
- Innovations in esthetics