Reverse Torque and Wear of Internal Connections of Metal-Based Abutments Under Cyclic Loading.

IF 3.2 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Daher Antonio Queiroz, Mariana Itaborai Moreira Freitas, Kaden Thomas Ockey, Damian Jaewhan Lee, Fengyuan Zheng
{"title":"Reverse Torque and Wear of Internal Connections of Metal-Based Abutments Under Cyclic Loading.","authors":"Daher Antonio Queiroz, Mariana Itaborai Moreira Freitas, Kaden Thomas Ockey, Damian Jaewhan Lee, Fengyuan Zheng","doi":"10.1111/jerd.13425","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Evaluate the reverse torque values and wear of internal connections caused by metal-based zirconia abutments under cyclic loading.</p><p><strong>Material and methods: </strong>Thirty implants were divided into three groups (n = 10), based on connection systems: Interference-fit cone-screw (Cortical Master Flash MI Fit-MTA and Cortical Master Flash MI RP-MTB), and Internal hexagon (Cortical Titanium Master Connect AR-IH). Metal-based zirconia abutments were tightened into the implant, and zirconia crowns were bonded using resin cement. All specimens underwent cyclic loading at 300 N and 9 Hz for 1,000,000 cycles. Reverse torques were assessed postloading, and wear was analyzed using scanning electron microscopy (SEM). Statistical analysis employed one-way ANOVA for reverse torque and wear values, with significant differences assessed via the Tukey test (α = 0.05).</p><p><strong>Results: </strong>Significant differences in reverse torque values were found among groups: MTA (24.9 N), MTB (24.1 N), and IH (14.4 N). The IH group showed higher mean wear values on the tension side (121.0) and compression side (112.6), with a wear difference of 8.4.</p><p><strong>Conclusion: </strong>The interference-fit cone-screw abutments demonstrated significantly reduced torque loss and morphology after cyclic loading, reflecting enhanced performance.</p><p><strong>Clinical significance: </strong>Although the stability of the metal base zirconia abutments to the implants was accurate, clinicians should be cautious about torque loss and more wear when using internal hexagon connections.</p>","PeriodicalId":15988,"journal":{"name":"Journal of Esthetic and Restorative Dentistry","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2025-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Esthetic and Restorative Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jerd.13425","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Evaluate the reverse torque values and wear of internal connections caused by metal-based zirconia abutments under cyclic loading.

Material and methods: Thirty implants were divided into three groups (n = 10), based on connection systems: Interference-fit cone-screw (Cortical Master Flash MI Fit-MTA and Cortical Master Flash MI RP-MTB), and Internal hexagon (Cortical Titanium Master Connect AR-IH). Metal-based zirconia abutments were tightened into the implant, and zirconia crowns were bonded using resin cement. All specimens underwent cyclic loading at 300 N and 9 Hz for 1,000,000 cycles. Reverse torques were assessed postloading, and wear was analyzed using scanning electron microscopy (SEM). Statistical analysis employed one-way ANOVA for reverse torque and wear values, with significant differences assessed via the Tukey test (α = 0.05).

Results: Significant differences in reverse torque values were found among groups: MTA (24.9 N), MTB (24.1 N), and IH (14.4 N). The IH group showed higher mean wear values on the tension side (121.0) and compression side (112.6), with a wear difference of 8.4.

Conclusion: The interference-fit cone-screw abutments demonstrated significantly reduced torque loss and morphology after cyclic loading, reflecting enhanced performance.

Clinical significance: Although the stability of the metal base zirconia abutments to the implants was accurate, clinicians should be cautious about torque loss and more wear when using internal hexagon connections.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Esthetic and Restorative Dentistry
Journal of Esthetic and Restorative Dentistry 医学-牙科与口腔外科
CiteScore
6.30
自引率
6.20%
发文量
124
审稿时长
>12 weeks
期刊介绍: The Journal of Esthetic and Restorative Dentistry (JERD) is the longest standing peer-reviewed journal devoted solely to advancing the knowledge and practice of esthetic dentistry. Its goal is to provide the very latest evidence-based information in the realm of contemporary interdisciplinary esthetic dentistry through high quality clinical papers, sound research reports and educational features. The range of topics covered in the journal includes: - Interdisciplinary esthetic concepts - Implants - Conservative adhesive restorations - Tooth Whitening - Prosthodontic materials and techniques - Dental materials - Orthodontic, periodontal and endodontic esthetics - Esthetics related research - Innovations in esthetics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信